Hager MBS116 Quickconnect Miniature Circuit Breaker B16 1-Pole 6 kA, 1 Module
3,72 € (3,02 € netto)
Technical data hide all Construction Number of protected poles: 1 Number of poles: 1 P Pole configuration: 1 P Tripping characteristic: B Functions With switched N pole: no Electrical characteristics Rated short-circuit breaking capacity Icn: 6 kA Rated operating voltage Ue (AC): 230 / 400 V Supply voltage type: AC Frequency: 50/60 Hz Voltage Rated insulation voltage Ui: 500 V Rated impulse withstand voltage Uimp: 4000 V Current Rated current In: 16 A Rated service short-circuit breaking capacity…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Technical data
hide all
Construction
Number of protected poles: 1
Number of poles: 1 P
Pole configuration: 1 P
Tripping characteristic: B
Functions
With switched N pole: no
Electrical characteristics
Rated short-circuit breaking capacity Icn: 6 kA
Rated operating voltage Ue (AC): 230 / 400 V
Supply voltage type: AC
Frequency: 50/60 Hz
Voltage
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4000 V
Current
Rated current In: 16 A
Rated service short-circuit breaking capacity Ics: 6 kA
Min./max. AC tripping current for time-delayed protection: 1.13 / 1.45 In
Min./max. AC tripping current for instantaneous protection: 3 / 5 In
Rated breaking capacity Icn below 230V AC according to IEC 60898-1: 6 kA
Rated ultimate short-circuit breaking capacity Icu for ETIM (EN 60947-2): 6 kA
Current / Temperature
Rated current at -25°C: 22.2 A
Rated current at -20°C: 21.69 A
Rated current at -15°C: 21.19 A
Rated current at -10°C: 20.89 A
Rated current at -5°C: 20.17 A
Rated current at 0°C: 19.66 A
Rated current at 5°C: 19.16 A
Rated current at 10°C: 18.65 A
Rated current at 15°C: 18.14 A
Rated current at 20°C: 17.63 A
Rated current at 25°C: 17.13 A
Rated current at 30°C: 16 A
Rated current at 35°C: 16.11 A
Rated current at 40°C: 15.6 A
Rated current at 45°C: 15.1 A
Rated current at 50°C: 15 A
Rated current at 55°C: 14.08 A
Rated current at 60°C: 13.57 A
Rated current at 65°C: 13.07 A
Rated current at 70°C: 12.56 A
Current correction factor
Rated current correction factor for 2 devices installed side by side: 1
Rated current correction factor for 3 devices installed side by side: 0.95
Rated current correction factor for 4 or 5 devices installed side by side: 0.9
Rated current correction factor for 6 devices installed side by side: 0.85
Instantaneous trip correction factor at 100 Hz: 1.1
Instantaneous trip correction factor at 200 Hz: 1.2
Instantaneous trip correction factor at 400 Hz: 1.5
Instantaneous trip correction factor at 60 Hz: 1
Frequency
Frequency (ETIM range): 50 to 60 Hz
Discrimination
Max. rated current of downstream aM fuse for short-circuit discrimination: 2 A
Max. rated current of downstream gL fuse for short-circuit discrimination: 6 A
Min. rated current of upstream aM fuse for short-circuit discrimination: 20 A
Min. rated current of upstream gL fuse for short-circuit discrimination: 20 A
Power
Maximum power dissipation per pole in accordance with the standard: 3.5 W
Total power loss at rated current: 2.44 W
Power loss per pole at rated current: 2.44 W
Durability
Electrical endurance (number of cycles): 4000
Mechanical endurance (number of cycles): 20000
Dimensions
Product Depth: 70 mm
Product height: 83.4 mm
Product width: 17.5 mm
Installation / Mounting
Suitable for flush mounting: yes
360° Mounting Position: yes
Connection
Output terminal capacity for flexible cable (stranded): 1 / 25 mm²
Output terminal capacity for rigid cable (solid): 1 / 35 mm²
Input terminal capacity for solid conductor (wire): 1 / 35 mm²
Input terminal capacity for flexible conductor (stranded): 1 / 25 mm²
SSK output terminal capacity for flexible conductor (stranded): 1.5 / 4 mm²
SSK output connection cross-section, with solid cable: 1.5 / 4 mm²
Phase bar with access terminal compliance: KDNxxx
Connection type: Quick Connect
Equipment
Quick Connect: yes
Standard
Standard: EN 60898-1
WEEE European Directive: applicable
Safety
Protection Rating (IP): IP20
Operating Conditions
Operating temperature: -25…70 °C
Pollution Degree per IEC 60664 / IEC 60947-2.: 2
Energy limitation class I²t.: 3
Storage/transport temperature: -25…80 °CTechnical Data
hide all
Construction
Number of protected poles: 1
Number of poles: 1 P
Pole configuration: 1 P
Tripping characteristic: B
Functions
With switched N pole: no
Electrical characteristics
Rated short-circuit breaking capacity Icn: 6 kA
Rated operating voltage Ue (AC): 230 / 400 V
Supply voltage type: AC
Frequency: 50/60 Hz
Voltage
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4000 V
Current
Rated current In: 16 A
Rated service short-circuit breaking capacity Ics: 6 kA
Min./max. AC tripping current for time-delayed protection: 1.13 / 1.45 In
Min./max. AC tripping current for instantaneous protection: 3 / 5 In
Rated breaking capacity Icn below 230V AC according to IEC 60898-1: 6 kA
Rated ultimate short-circuit breaking capacity Icu for ETIM (EN 60947-2): 6 kA
Current / Temperature
Rated current at -25°C: 22.2 A
Rated current at -20°C: 21.69 A
Rated current at -15°C: 21.19 A
Rated current at -10°C: 20.89 A
Rated current at -5°C: 20.17 A
Rated current at 0°C: 19.66 A
Rated current at 5°C: 19.16 A
Rated current at 10°C: 18.65 A
Rated current at 15°C: 18.14 A
Rated current at 20°C: 17.63 A
Rated current at 25°C: 17.13 A
Rated current at 30°C: 16 A
Rated current at 35°C: 16.11 A
Rated current at 40°C: 15.6 A
Rated current at 45°C: 15.1 A
Rated current at 50°C: 15 A
Rated current at 55°C: 14.08 A
Rated current at 60°C: 13.57 A
Rated current at 65°C: 13.07 A
Rated current at 70°C: 12.56 A
Current correction factor
Rated current correction factor for 2 devices installed side by side: 1
Rated current correction factor for 3 devices installed side by side: 0.95
Rated current correction factor for 4 or 5 devices installed side by side: 0.9
Rated current correction factor for 6 devices installed side by side: 0.85
Instantaneous trip correction factor at 100 Hz: 1.1
Instantaneous trip correction factor at 200 Hz: 1.2
Instantaneous trip correction factor at 400 Hz: 1.5
Instantaneous trip correction factor at 60 Hz: 1
Frequency
Frequency (ETIM range): 50 to 60 Hz
Discrimination
Max. rated current of downstream aM fuse for short-circuit discrimination: 2 A
Max. rated current of downstream gL fuse for short-circuit discrimination: 6 A
Min. rated current of upstream aM fuse for short-circuit discrimination: 20 A
Min. rated current of upstream gL fuse for short-circuit discrimination: 20 A
Power
Maximum power dissipation per pole in accordance with the standard: 3.5 W
Total power loss at rated current: 2.44 W
Power loss per pole at rated current: 2.44 W
Durability
Electrical endurance (number of cycles): 4000
Mechanical endurance (number of cycles): 20000
Dimensions
Product Depth: 70 mm
Product height: 83.4 mm
Product width: 17.5 mm
Installation / Mounting
Suitable for flush mounting: yes
360° Mounting Position: yes
Connection
Output terminal capacity for flexible cable (stranded): 1 / 25 mm²
Output terminal capacity for rigid cable (solid): 1 / 35 mm²
Input terminal capacity for solid conductor (wire): 1 / 35 mm²
Input terminal capacity for flexible conductor (stranded): 1 / 25 mm²
SSK output terminal capacity for flexible conductor (stranded): 1.5 / 4 mm²
SSK output connection cross-section, with solid cable: 1.5 / 4 mm²
Phase bar with access terminal compliance: KDNxxx
Connection type: Quick Connect
Equipment
Quick Connect: yes
Standard
Standard: EN 60898-1
WEEE European Directive: applicable
Safety
Protection Rating (IP): IP20
Operating Conditions
Operating temperature: -25…70 °C
Pollution Degree per IEC 60664 / IEC 60947-2.: 2
Energy limitation class I²t.: 3
Storage/transport temperature: -25…80 °C
Technical Data – Miniature Circuit Breaker
| Voltage Type | AC |
| Mounting Depth | 70 mm |
| Rated Current | 16 A |
| Rated Voltage | 400 V |
| Frequency Range | 50 Hz |
| Tripping Characteristic | B |
| Rated insulation voltage Ui | 500 V |
| Energy Limiting Class | 3 |
| Overvoltage Category | 3 |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 1 |
| Power losses | 2.44 W |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 1 |
| Cross-section of connectable single-wire conductor | 1 mm2 |
| Cross-section of connectable multi-wire conductor | 1 mm2 |
| Ambient operating temperature | -25 °C |
| Number of Poles (Total) | 1 |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V | 6 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V | 6 kA |
| Rated impulse withstand voltage Uimp | 4 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,092 kg |
|---|---|
| Dimensions | 7,4 × 1,75 × 8,7 cm |
| Brand | Hager |
| Length | 1 m |
| Rated Current | 16 A |