Hager NBN220 Miniature Circuit Breaker B20 2-Pole 10 kA, 2 Modules

32,52 € (26,44 € netto)

Lowest price in the last 30 days: 32,52 €

Technical data hide all Construction Number of protected poles: 2 Number of poles: 2 P Pole configuration: 2 P Mounting: DIN rail Tripping characteristic: B Functions With switched N pole: no Compatibility DIN rail mounting compatibility: yes Controls and indicators With fault indication: no Electrical characteristics Rated short-circuit breaking capacity Icn: 10 kA Rated operational voltage Ue (AC): 400 V Supply voltage type: AC Voltage Rated insulation voltage Ui: 500 V Rated impulse withstand voltage Uimp: 6000 V Minimum rated…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: NBN220 Category: EAN: 3250614613883 Brand:

Description

 

Technical data

hide all

Construction

Number of protected poles: 2

Number of poles: 2 P

Pole configuration: 2 P

Mounting: DIN rail

Tripping characteristic: B

Functions

With switched N pole: no

Compatibility

DIN rail mounting compatibility: yes

Controls and indicators

With fault indication: no

Electrical characteristics

Rated short-circuit breaking capacity Icn: 10 kA

Rated operational voltage Ue (AC): 400 V

Supply voltage type: AC

Voltage

Rated insulation voltage Ui: 500 V

Rated impulse withstand voltage Uimp: 6000 V

Minimum rated operational voltage (Ue min): 12 V

Current

Rated current In: 20 A

Rated service short-circuit breaking capacity Ics: 7.5 kA

Min./max. AC tripping current for time-delayed protection: 1.13 / 1.45 In

Min./max. AC tripping current for instantaneous protection: 3 / 5 In

Min./max. DC tripping current of instantaneous protection: 4 / 7 In

Min./max. DC tripping current of time-delayed protection: 1.13 / 1.45 In

Rated current at -10°C according to EN 60947: 26.75 A

Rated current at -15°C according to EN 60947: 27.24 A

Rated current at -20°C according to EN 60947: 27.72 A

Rated current at -25°C according to EN 60947: 28.19 A

Rated current at -5°C according to EN 60947: 26.26 A

Rated current at 0°C according to EN 60947: 25.75 A

Rated current at 10°C according to EN 60947: 24.71 A

Rated current at 15°C according to EN 60947: 24.17 A

Rated current at 20°C according to EN 60947: 23.62 A

Rated current at 25°C according to EN 60947: 23.06 A

Rated current at 30°C according to EN 60947: 22.48 A

Rated current at 35°C according to EN 60947: 21.88 A

Rated current at 40°C in accordance with EN 60947: 21.28 A

Rated current at 45°C in accordance with EN 60947: 20.65 A

Rated current at 5°C in accordance with EN 60947: 25.24 A

Rated current at 50°C in accordance with EN 60947: 20 A

Rated current at 55°C in accordance with EN 60947: 19.33 A

Rated current at 60°C in accordance with EN 60947: 18.64 A

Rated current at 65°C in accordance with EN 60947: 17.92 A

Rated current at 70°C in accordance with EN 60947: 17.17 A

Rated short-circuit breaking capacity Icn for 220V AC acc. to EN 60947-2: 15 kA

Rated short-circuit breaking capacity Icn for 230V AC acc. to EN 60947-2: 15 kA

Rated short-circuit breaking capacity Icn for 240V AC acc. to EN 60947-2: 15 kA

Rated short-circuit breaking capacity Icn for 380V AC acc. to EN 60947-2: 7.5 kA

Rated short-circuit breaking capacity Icn for 400V AC acc. to EN 60947-2: 7.5 kA

Rated short-circuit breaking capacity Icn for 415V AC acc. to EN 60947-2: 7.5 kA

Rated short-circuit breaking capacity Icn below 230V AC in accordance with IEC 60898-1: 10 kA

Rated short-circuit breaking capacity Icn below 400V AC in accordance with IEC 60898-1: 10 kA

Rated ultimate short-circuit breaking current Icu for ETIM (EN 60947-2): 30 kA

Breaking capacity 240V (NF EN 60947-2): 30 kA

Breaking capacity 400V (NF EN 60947-2): 15 kA

Breaking capacity 415V (NF EN 60947-2): 15 kA

Rated short-circuit breaking capacity Icn below 240V AC in accordance with IEC 60898-1: 10 kA

Rated short-circuit breaking capacity Icn below 380V AC in accordance with IEC 60898-1: 10 kA

Rated short-circuit breaking capacity Icn below 415V AC in accordance with IEC 60898-1: 10 kA

Rated short-circuit breaking capacity Icn for 220V AC acc. to EN 60898-1: 7.5 kA

Rated short-circuit breaking capacity Icn for 230V AC acc. to EN 60898-1: 7.5 kA

Rated short-circuit breaking capacity Icn for 240V AC acc. to EN 60898-1: 7.5 kA

Rated short-circuit breaking capacity Icn for 380V AC acc. to EN 60898-1: 7.5 kA

Rated short-circuit breaking capacity Icn for 400V AC acc. to EN 60898-1: 7.5 kA

Rated short-circuit breaking capacity Icn for 415V AC acc. to EN 60898-1: 7.5 kA

Rated ultimate short-circuit breaking current Icu for 220V AC acc. to EN 60947-2: 30 kA

Rated ultimate short-circuit breaking current Icu for 380V AC acc. to EN 60947-2: 15 kA

Current / Temperature

Rated current at -25°C: 25.08 A

Rated current at -20°C: 24.66 A

Rated current at -15°C: 24.24 A

Rated current at -10°C: 23.8 A

Rated current at -5°C: 23.36 A

Rated current at 0°C: 22.91 A

Rated current at 5°C: 22.45 A

Rated current at 10°C: 21.98 A

Rated current at 25°C: 20.51 A

Rated current at 30°C: 20 A

Rated current at 35°C: 19.47 A

Rated current at 40°C: 18.93 A

Rated current at 45°C: 18.37 A

Rated current at 50°C: 17.8 A

Rated current at 55°C: 17.2 A

Rated current at 60°C: 16.58 A

Rated current at 65°C: 15.94 A

Rated current at 70°C: 15.28 A

Current correction factor

Rated current correction factor for 2 devices installed side by side: 1

Rated current correction factor for 3 devices installed side by side: 0.95

Rated current correction factor for 4 or 5 devices installed side by side: 0.9

Rated current correction factor for 6 devices installed side by side: 0.85

Instantaneous trip correction factor at 100 Hz: 1.1

Instantaneous trip correction factor at 200 Hz: 1.2

Instantaneous trip correction factor at 400 Hz: 1.5

Correction factor for instantaneous trip at 60 Hz frequency: 1.1

Frequency

Frequency (ETIM range): 50 to 60 Hz

Power

Maximum power loss per pole according to standard: 4.5 W

Total power loss at rated current: 5.29 W

Power loss per pole at rated current: 2.68 W

Durability

Electrical endurance (number of cycles): 4000

Mechanical endurance (number of cycles): 20000

Dimensions

Product Depth: 70 mm

Product Height: 83 mm

Product width: 35 mm

Installation / Mounting

Tightening Torque: 2.8 Nm

Easy removal of modular devices: yes

Possibility of removal from the bottom: yes

Suitable for flush mounting: yes

360° Mounting Position: yes

Connection

Output terminal capacity for flexible cable (stranded): 1 / 25 mm²

Output terminal capacity for rigid cable (solid): 1 / 35 mm²

Input terminal capacity for solid conductor (wire): 1 / 35 mm²

Input terminal capacity for flexible conductor (stranded): 1 / 25 mm²

Equipment

Additional accessories: yes

Transparent cover for labelling field: yes

Standard

Standard: EN 60898-1, IEC 60947-2

WEEE European Directive: applicable

Safety

Protection Rating (IP): IP20

Operating Conditions

Operating temperature: -25…70 °C

Pollution Degree per IEC 60664 / IEC 60947-2.: 2

Energy limitation class I²t.: 3

Storage/transport temperature: -25…80 °C

Temperature

Calibration temperature: 50 °C

Technical Data – Miniature Circuit Breaker

Voltage TypeAC
Mounting Depth70 mm
Rated Current20 A
Rated Voltage400 V
Frequency Range50 Hz
Tripping CharacteristicB
Rated insulation voltage Ui500 V
Energy Limiting Class3
Overvoltage Category3
Pollution degree (N)2
Width in Number of Modules2
Explosion-Proof DesignNo
Power losses5.29 W
Protection Rating (IP)IP20
Number of Protected Poles2
Simultaneously disconnected N poleNo
Cross-section of connectable single-wire conductor1 mm2
Cross-section of connectable multi-wire conductor1 mm2
Ambient operating temperature-25 °C
Flush mountingYes
Possibility of additional accessoriesYes
Number of Poles (Total)2
Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V10 kA
Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V10 kA
Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V30 kA
Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V15 kA
Rated impulse withstand voltage Uimp6 kV

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,241 kg
Dimensions8 × 4 × 7 cm
Brand

Hager

Length

2 m

Rated Current

16 A

Reviews

There are no reviews yet.

Be the first to review “Hager NBN220 Miniature Circuit Breaker B20 2-Pole 10 kA, 2 Modules”

Your email address will not be published. Required fields are marked *