Hager NBN220 Miniature Circuit Breaker B20 2-Pole 10 kA, 2 Modules
32,52 € (26,44 € netto)
Technical data hide all Construction Number of protected poles: 2 Number of poles: 2 P Pole configuration: 2 P Mounting: DIN rail Tripping characteristic: B Functions With switched N pole: no Compatibility DIN rail mounting compatibility: yes Controls and indicators With fault indication: no Electrical characteristics Rated short-circuit breaking capacity Icn: 10 kA Rated operational voltage Ue (AC): 400 V Supply voltage type: AC Voltage Rated insulation voltage Ui: 500 V Rated impulse withstand voltage Uimp: 6000 V Minimum rated…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Â
Technical data
hide all
Construction
Number of protected poles: 2
Number of poles: 2 P
Pole configuration: 2 P
Mounting: DIN rail
Tripping characteristic: B
Functions
With switched N pole: no
Compatibility
DIN rail mounting compatibility: yes
Controls and indicators
With fault indication: no
Electrical characteristics
Rated short-circuit breaking capacity Icn: 10 kA
Rated operational voltage Ue (AC): 400 V
Supply voltage type: AC
Voltage
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 6000 V
Minimum rated operational voltage (Ue min): 12 V
Current
Rated current In: 20 A
Rated service short-circuit breaking capacity Ics: 7.5 kA
Min./max. AC tripping current for time-delayed protection: 1.13 / 1.45 In
Min./max. AC tripping current for instantaneous protection: 3 / 5 In
Min./max. DC tripping current of instantaneous protection: 4 / 7 In
Min./max. DC tripping current of time-delayed protection: 1.13 / 1.45 In
Rated current at -10°C according to EN 60947: 26.75 A
Rated current at -15°C according to EN 60947: 27.24 A
Rated current at -20°C according to EN 60947: 27.72 A
Rated current at -25°C according to EN 60947: 28.19 A
Rated current at -5°C according to EN 60947: 26.26 A
Rated current at 0°C according to EN 60947: 25.75 A
Rated current at 10°C according to EN 60947: 24.71 A
Rated current at 15°C according to EN 60947: 24.17 A
Rated current at 20°C according to EN 60947: 23.62 A
Rated current at 25°C according to EN 60947: 23.06 A
Rated current at 30°C according to EN 60947: 22.48 A
Rated current at 35°C according to EN 60947: 21.88 A
Rated current at 40°C in accordance with EN 60947: 21.28 A
Rated current at 45°C in accordance with EN 60947: 20.65 A
Rated current at 5°C in accordance with EN 60947: 25.24 A
Rated current at 50°C in accordance with EN 60947: 20 A
Rated current at 55°C in accordance with EN 60947: 19.33 A
Rated current at 60°C in accordance with EN 60947: 18.64 A
Rated current at 65°C in accordance with EN 60947: 17.92 A
Rated current at 70°C in accordance with EN 60947: 17.17 A
Rated short-circuit breaking capacity Icn for 220V AC acc. to EN 60947-2: 15 kA
Rated short-circuit breaking capacity Icn for 230V AC acc. to EN 60947-2: 15 kA
Rated short-circuit breaking capacity Icn for 240V AC acc. to EN 60947-2: 15 kA
Rated short-circuit breaking capacity Icn for 380V AC acc. to EN 60947-2: 7.5 kA
Rated short-circuit breaking capacity Icn for 400V AC acc. to EN 60947-2: 7.5 kA
Rated short-circuit breaking capacity Icn for 415V AC acc. to EN 60947-2: 7.5 kA
Rated short-circuit breaking capacity Icn below 230V AC in accordance with IEC 60898-1: 10 kA
Rated short-circuit breaking capacity Icn below 400V AC in accordance with IEC 60898-1: 10 kA
Rated ultimate short-circuit breaking current Icu for ETIM (EN 60947-2): 30 kA
Breaking capacity 240V (NF EN 60947-2): 30 kA
Breaking capacity 400V (NF EN 60947-2): 15 kA
Breaking capacity 415V (NF EN 60947-2): 15 kA
Rated short-circuit breaking capacity Icn below 240V AC in accordance with IEC 60898-1: 10 kA
Rated short-circuit breaking capacity Icn below 380V AC in accordance with IEC 60898-1: 10 kA
Rated short-circuit breaking capacity Icn below 415V AC in accordance with IEC 60898-1: 10 kA
Rated short-circuit breaking capacity Icn for 220V AC acc. to EN 60898-1: 7.5 kA
Rated short-circuit breaking capacity Icn for 230V AC acc. to EN 60898-1: 7.5 kA
Rated short-circuit breaking capacity Icn for 240V AC acc. to EN 60898-1: 7.5 kA
Rated short-circuit breaking capacity Icn for 380V AC acc. to EN 60898-1: 7.5 kA
Rated short-circuit breaking capacity Icn for 400V AC acc. to EN 60898-1: 7.5 kA
Rated short-circuit breaking capacity Icn for 415V AC acc. to EN 60898-1: 7.5 kA
Rated ultimate short-circuit breaking current Icu for 220V AC acc. to EN 60947-2: 30 kA
Rated ultimate short-circuit breaking current Icu for 380V AC acc. to EN 60947-2: 15 kA
Current / Temperature
Rated current at -25°C: 25.08 A
Rated current at -20°C: 24.66 A
Rated current at -15°C: 24.24 A
Rated current at -10°C: 23.8 A
Rated current at -5°C: 23.36 A
Rated current at 0°C: 22.91 A
Rated current at 5°C: 22.45 A
Rated current at 10°C: 21.98 A
Rated current at 25°C: 20.51 A
Rated current at 30°C: 20 A
Rated current at 35°C: 19.47 A
Rated current at 40°C: 18.93 A
Rated current at 45°C: 18.37 A
Rated current at 50°C: 17.8 A
Rated current at 55°C: 17.2 A
Rated current at 60°C: 16.58 A
Rated current at 65°C: 15.94 A
Rated current at 70°C: 15.28 A
Current correction factor
Rated current correction factor for 2 devices installed side by side: 1
Rated current correction factor for 3 devices installed side by side: 0.95
Rated current correction factor for 4 or 5 devices installed side by side: 0.9
Rated current correction factor for 6 devices installed side by side: 0.85
Instantaneous trip correction factor at 100 Hz: 1.1
Instantaneous trip correction factor at 200 Hz: 1.2
Instantaneous trip correction factor at 400 Hz: 1.5
Correction factor for instantaneous trip at 60 Hz frequency: 1.1
Frequency
Frequency (ETIM range): 50 to 60 Hz
Power
Maximum power loss per pole according to standard: 4.5 W
Total power loss at rated current: 5.29 W
Power loss per pole at rated current: 2.68 W
Durability
Electrical endurance (number of cycles): 4000
Mechanical endurance (number of cycles): 20000
Dimensions
Product Depth: 70 mm
Product Height: 83 mm
Product width: 35 mm
Installation / Mounting
Tightening Torque: 2.8 Nm
Easy removal of modular devices: yes
Possibility of removal from the bottom: yes
Suitable for flush mounting: yes
360° Mounting Position: yes
Connection
Output terminal capacity for flexible cable (stranded): 1 / 25 mm²
Output terminal capacity for rigid cable (solid): 1 / 35 mm²
Input terminal capacity for solid conductor (wire): 1 / 35 mm²
Input terminal capacity for flexible conductor (stranded): 1 / 25 mm²
Equipment
Additional accessories: yes
Transparent cover for labelling field: yes
Standard
Standard: EN 60898-1, IEC 60947-2
WEEE European Directive: applicable
Safety
Protection Rating (IP): IP20
Operating Conditions
Operating temperature: -25…70 °C
Pollution Degree per IEC 60664 / IEC 60947-2.: 2
Energy limitation class I²t.: 3
Storage/transport temperature: -25…80 °C
Temperature
Calibration temperature: 50 °C
Technical Data – Miniature Circuit Breaker
| Voltage Type | AC |
| Mounting Depth | 70 mm |
| Rated Current | 20 A |
| Rated Voltage | 400 V |
| Frequency Range | 50 Hz |
| Tripping Characteristic | B |
| Rated insulation voltage Ui | 500 V |
| Energy Limiting Class | 3 |
| Overvoltage Category | 3 |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 2 |
| Explosion-Proof Design | No |
| Power losses | 5.29 W |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 2 |
| Simultaneously disconnected N pole | No |
| Cross-section of connectable single-wire conductor | 1 mm2 |
| Cross-section of connectable multi-wire conductor | 1 mm2 |
| Ambient operating temperature | -25 °C |
| Flush mounting | Yes |
| Possibility of additional accessories | Yes |
| Number of Poles (Total) | 2 |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V | 10 kA |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V | 10 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V | 30 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V | 15 kA |
| Rated impulse withstand voltage Uimp | 6 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,241 kg |
|---|---|
| Dimensions | 8 × 4 × 7 cm |
| Brand | Hager |
| Length | 2 m |
| Rated Current | 16 A |












Reviews
There are no reviews yet.