ETI Etimat 10 Miniature Circuit Breaker B6 1-Pole 10 kA, 1 Module

4,38 € (3,56 € netto)

Lowest price in the last 30 days: 4,38 €

Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters Catalogue Number: Individual identification number assigned by the manufacturer. 002121712 Product Code: Product type as specified by the manufacturer. ETIMAT 10 1p B6 Class Name: Miniature circuit breakers are used to protect electrical…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 002121712 Category: EAN: 5904722937536 Brand:

Description

Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters

  • Catalogue Number:
  • Individual identification number assigned by the manufacturer. 002121712

  • Product Code:
  • Product type as specified by the manufacturer. ETIMAT 10 1p B6

  • Class Name:
  • Miniature circuit breakers are used to protect electrical installations in residential, public, and industrial buildings. Miniature Circuit Breaker

  • Rated Current [A]:
  • The current value set by the manufacturer that the device can carry during continuous operation, at a specified reference ambient air temperature. 6

  • Tripping Characteristic:
  • Miniature circuit breakers should have an operating characteristic that ensures proper circuit protection without causing premature or delayed tripping.
    Standardised instantaneous tripping ranges:
    – Type B (Above 3 In up to and including 5 In)
    – Type C (Above 5 In up to and including 10 In)
    – Type D (Above 10 In up to and including 20 In) B

  • Number of Poles:
  • Design version of a given modular switch: single-, double-, triple- and four-pole. 1

  • Short-Circuit Current [kA]:
  • Overcurrent that occurs in the event of a short circuit resulting from damage or improper connection in the electrical circuit. 10

  • Rated Voltage AC [V]:
  • The rated AC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 230/400

  • Rated Voltage DC [V]:
  • The rated DC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 60

  • Rated Frequency [Hz]:
  • The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60

  • Voltage Uimp [kV]:
  • The peak value of a voltage surge of a specified shape and polarity that an electrical device can withstand without damage under specified test conditions, to which the insulation clearance values refer. 6

  • IP Protection Rating:
  • Degree of protection against access to hazardous parts and against the ingress of solid foreign objects and/or water, specified in accordance with EN 60529. IP20

  • Ambient Temperature [˚C]
  • The temperature of the air surrounding the complete switching device under specified conditions. For switching devices installed inside an enclosure, this refers to the air temperature outside the enclosure. -25 to +55

  • Contact Gap [mm]:
  • The distance between the main contacts of the switching device in the open position, expressed in millimetres. >3

  • Conductor Connection Capacity [mm2]:
  • The size of the connection terminal of the switching device, allowing for the connection of a conductor with an appropriate cross-section, expressed in mm2. 1 – 25

  • Operating Position:
  • Specification of the position in which the device can operate, e.g. horizontally, vertically, top-mounted, side-mounted. any

  • Standards:
  • Standards according to which the device was designed, tested and certified. IEC/EN 60898-1,
    IEC 60947-2

  • Function:
  • Miniature circuit breaker, MCB (ang. miniature circuit breaker) MCB

    Product photo

    3D

    Product advantages

    • possibility of mounting auxiliary contacts (PS ETIMAT 10).
    • possibility of mounting a shunt trip (DA ETIMAT 10).
    • possibility of supply from below or above.
    • possibility of double connection to the insulated busbar – top and bottom.
    • contact position indicator.
    • ability to seal the lever in the “On” and “Off” positions
    • “ON/OFF” marking on the switching lever.
    • Each circuit breaker marked with an EAN code.
    • Modern TH35 rail mounting method and easy replacement.

    Dimensional drawing

    ETIsON Curves

    Programme functionalities:

    • generating and plotting t/I characteristics of protective devices
    • adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
    • analysing selectivity between protective devices
    • simulating load or short-circuit response of protective devices
    • defining operating points and limit conditions from real applications
    • preparing reports for design documentation
    • Check how simple it is!

    Technical Data – Miniature Circuit Breaker

    Frequency50 Hz
    Voltage TypeOther
    Mounting Depth68 mm
    Rated Current6 A
    Frequency Range50 Hz
    Tripping CharacteristicB
    Rated insulation voltage Ui500 V
    Energy Limiting Class3
    Overvoltage Category3
    Pollution degree (N)3
    Width in Number of Modules1
    Protection Rating (IP)IP20
    Number of Protected Poles1
    Rated Short-Circuit Breaking Capacity according to EN 6089810 kA
    Cross-section of connectable single-wire conductor1 mm2
    Cross-section of connectable multi-wire conductor1 mm2
    Ambient operating temperature-25 °C
    Number of Poles (Total)1
    Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V10 kA
    Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V10 kA
    Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V15 kA
    Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V15 kA

    Safety instructions: hilark.eu/gpsr/en.

    Additional information

    Weight0,102 kg
    Dimensions8,5 × 7,2 × 1,7 cm
    Brand

    ETI

    Length

    1 m

    Reviews

    There are no reviews yet.

    Be the first to review “ETI Etimat 10 Miniature Circuit Breaker B6 1-Pole 10 kA, 1 Module”

    Your email address will not be published. Required fields are marked *