F&F CZF-2B Phase Failure Sensor 10A 1NO 3X400/230V+N AC with Contactor Control

26,77 € (21,76 € netto)

Lowest price in the last 30 days: 26,77 €

Non-isolated 1 x NO contact. The phase loss sensor with contactor contact monitoring is designed to protect electric motors supplied from a three-phase network in situations involving voltage loss in at least one phase, voltage asymmetry between phases, or damage to the switching contactor’s contacts, which could damage the motor. Supply voltage 3 × 400 V + N Compatible with generator sets NO Phase loss / asymmetry control YES Phase sequence control NO Contactor contact monitoring YES Actuating element relay Maximum load current 10 A…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: CZF-2B Category: EAN: 5908312593065 Brand:

Description

Non-isolated 1 x NO contact. The phase loss sensor with contactor contact monitoring is designed to protect electric motors supplied from a three-phase network in situations involving voltage loss in at least one phase, voltage asymmetry between phases, or damage to the switching contactor’s contacts, which could damage the motor. Supply voltage 3 × 400 V + N Compatible with generator sets NO Phase loss / asymmetry control YES Phase sequence control NO Contactor contact monitoring YES Actuating element relay Maximum load current 10 A Contact configuration 1 × NO Contact isolation NO Voltage asymmetry trip threshold 55 V Voltage hysteresis 5 V Shutdown delay 4 s Power supply monitoring 2 × LED Connection screw terminals 4.0 mm² Tightening torque 0.5 Nm Power consumption 1.6 W Operating temperature -25÷40°C Dimensions 2 modules (35 mm) DIN rail mounting 35 mm Protection Rating (IP) IP20

Technical Data – Phase Control Relay

Width0 mm
Height0 mm
Depth0 mm
Voltage Measurement Range140 V
Supply voltage typeAC
Type of Electrical ConnectionScrew Connection
Supply Voltage TypeAC
Rated Making Current10 A
Supply voltage for AC 50 Hz150 V
Maximum Allowable Delay on Power-Up4 s
Minimum Adjustable Delay on Power-Up4 s
Maximum Allowable Delay on Power Failure4 s
Minimum Adjustable Delay on Power Failure4 s
Operating voltage for AC 50 Hz150 V
Number of NC Contacts1
Number of NO Contacts0
Number of Changeover Contacts0

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,096 kg
Dimensions9,5 × 9,5 × 4 cm
Brand

F&F

Rated Current

10 A

Number of Phases

Single Phase

Reviews

There are no reviews yet.

Be the first to review “F&F CZF-2B Phase Failure Sensor 10A 1NO 3X400/230V+N AC with Contactor Control”