CKF-316 Phase Sequence and Phase Failure Sensor – Product Template – F&F Home and Industrial Automation CKF-316 Phase Sequence and Phase Failure Sensor CKF-316 Phase Sequence and Phase Failure Sensor for Motor Protection The CKF-316 is a phase control relay designed to protect electric motors powered from a 3 × 400 V + N three-phase mains supply. The device monitors voltage loss on any phase, voltage asymmetry between phases, exceeding permissible phase voltage values, and correct phase sequence, thereby reducing the risk of drive damage and unwanted reversal of rotation direction…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
CKF-316 Phase Sequence and Failure Sensor – Product Template – F&F home and industrial automation
CKF-316
CKF-316 Phase Sequence and Failure Sensor
Phase sequence and failure sensor for motor protection
The CKF-316 is a phase control relay designed to protect electric motors supplied from a three-phase 3 × 400 V + N network. The device monitors voltage loss in any phase, voltage asymmetry between phases, exceeding permissible phase voltage values, and correct phase sequence, thereby reducing the risk of drive damage and unwanted reversal of the motor’s direction of rotation. This is a practical solution for industrial automation, machine installations, control switchboards and drive systems requiring stable and safe operation. The sensor uses a fixed voltage asymmetry trip threshold of 55 V and a 5 V hysteresis, while the 4 s switch-off delay helps avoid unnecessary motor stoppage during brief voltage dips. In the event of phase loss, exceeded asymmetry or incorrect phase sequence, the device blocks motor start-up or disconnects it via a 1 × NO/NC relay contact. The CKF-316 supports protection of three-phase motors, phase sequence monitoring and power supply asymmetry protection in automation systems. As a product in the phase failure sensors and phase voltage sensors category, it helps increase installation reliability, improve operational safety and reduce downtime and repair costs. Mounting on a TH-35 DIN rail, a width of one module and screw terminals make it easy to integrate the device into standard switchboards.
Why choose the CKF-316?
Power supply 3 × 400 V + N
Phase failure and asymmetry monitoring
Phase sequence monitoring
Asymmetry threshold 55 V
Power consumption 1.6W
Switch-off delay 4 s
Isolated relay contact 1 × NO/NC
DIN TH-35 rail mounting
Single module width 18 mm
Motor protection against phase failure
The CKF-316 monitors the presence of voltage in each phase of the three-phase network. In the event of voltage loss in at least one phase, the device disconnects the motor, protecting the windings and reducing the risk of costly drive failure.
Fixed voltage asymmetry threshold
The sensor responds to voltage asymmetry exceeding 55 V, and automatic reconnection occurs once the asymmetry drops by the 5 V hysteresis value. This ensures stable control of supply conditions without the need for manual threshold adjustment.
Lock-out on incorrect phase sequence
The device detects an incorrect phase sequence that could cause a reversal of the motor’s direction of rotation. Blocking start-up until the correct sequence is restored increases the safety of machines and technological processes.
Reliable control
Monitors key three-phase power supply parameters.
Compact installation
Occupies a single module in the switchboard.
LED signalling
Enables quick assessment of operating status.
CKF-316 – device visualisation
Discover other advantages of the CKF-316
Modular 18 mm enclosure
The device has a compact enclosure, one module wide, designed for installation in a switchboard.
TH-35 rail mounting
The shape of the enclosure allows installation on a standard TH-35 rail used in modular equipment.
Screw terminals for conductors
Screw terminals for connecting phases, the neutral conductor and the relay contact are visible on the front of the enclosure.
Two LED signal indicators
The front panel is fitted with two LEDs indicating the power supply status and incorrect phase sequence.
Terminal markings on the enclosure
The enclosure features clear terminal markings, making it easier to identify phase paths and contacts.
Additional materials
See also: CKF-318, CZF-BT Phase Control Relays
See also: Video Tutorial Practical Electrician – CKF 318 – phase sequence sensor
HEAT PUMP PROTECTION
GUIDE
How to check the phase sequence in a three-phase low-voltage electrical installation
GUIDE
Diagrams
Dimensions Connection Diagram
Technical Parameters
With Removable Terminals No External Power Supply Required Yes Phase Sequence Control Yes Phase Failure Detection Yes Undervoltage Control Function Yes Overvoltage Control Function No Phase Asymmetry Control Yes Minimum Adjustable Delay on Power Failure 1 s Number of NO Contacts 0 Electrical Connection Type Screw Connection Supply Voltage for AC 50 Hz 150-280 V Minimum Adjustable Delay on Power-Up 4 s Maximum Allowable Delay on Power-Up 4 s Maximum Allowable Delay on Power Failure 1 s Number of NC Contacts 0 Number of CO Contacts 1 Operating Voltage for AC 50 Hz 150-280 V Rated Switching Current 10 A Supply Voltage Type AC Supply Voltage Type AC Depth 0 mm Height 0 mm Width 0 mm
Discover our other solutions!
| CKF CKF With a fixed voltage asymmetry trip threshold. 1 x NO contact. Sensor for phase sequence and phase failure designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor. | CKF-316-TRMS CKF-316-TRMS With a fixed voltage asymmetry trip threshold. 1 x NO/NC contact. Application: for protecting electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-316-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-319-TRMS CKF-319-TRMS CKF-319 TrueRMS Phase Sequence and Phase Failure Sensor For protecting electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-319-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-317-TRMS CKF-317-TRMS With an adjustable voltage asymmetry trip threshold. 1 x NO/NC contact. The phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The sensor will trip when voltage is lost in at least one phase or when voltage asymmetry occurs between phases (risk of motor damage). The CKF-317-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-BR-TRMS CKF-BR-TRMS With an adjustable voltage asymmetry trip threshold. 1 x NO/NC contact. The CKF-BR TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor. The CKF-BR-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction | CKF-B-TRMS CKF-B-TRMS With a fixed voltage asymmetry trip threshold. 1 x NO contact. The CKF-B TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor. | CKF-BT-TRMS CKF-BT-TRMS With adjustable trip delay time. 1NO/NC contact. The CKF-BT-TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-BT-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-TRMS CKF-TRMS With a fixed voltage asymmetry trip threshold. 1 x NO contact. The CKF TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor. |
|---|
Files to download
CKF-316-declaration-pref-origin-status-1.pdf CKF-316-declaration-RoHS-pl-1.pdf ckf-316-instrukcja-obslugi.pdf ckf-316-true-rms-instrukcja-obslugi.pdf ckf-316-schemat-cad-dxf.dxf ckf-czf-cp-deklaracja-ce-2025.pdf
About F&F
F&F is a Polish manufacturer of home and industrial automation with many years of experience. For years we have been delivering innovative, reliable and easy-to-use solutions that enhance comfort and safety in homes and production facilities. We design and manufacture our devices entirely in Poland, placing particular emphasis on quality, modern technologies and technical support for our customers.
Polish manufacturer of home and industrial automation
Technical Data – Phase Control Relay
| Width | 0 mm |
| Height | 0 mm |
| Depth | 0 mm |
| Voltage Measurement Range | 190 V |
| Supply voltage type | AC |
| Type of Electrical Connection | Screw Connection |
| Supply Voltage Type | AC |
| Rated Making Current | 10 A |
| Supply voltage for AC 50 Hz | 150 V |
| Maximum Allowable Delay on Power-Up | 4 s |
| Minimum Adjustable Delay on Power-Up | 4 s |
| Maximum Allowable Delay on Power Failure | 1 s |
| Minimum Adjustable Delay on Power Failure | 1 s |
| Operating voltage for AC 50 Hz | 150 V |
| Number of NC Contacts | 0 |
| Number of NO Contacts | 0 |
| Number of Changeover Contacts | 1 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,072 kg |
|---|---|
| Dimensions | 9,5 × 9,5 × 2 cm |
| Brand | F&F |
| Length | 1 m |
| Rated Current | 10 A |
| Number of Phases | Single Phase |