ETI Miniature Circuit Breaker Etimat 10 C100 3-Pole 20 kA, 4.5 Modules

142,82 € (116,11 € netto)

Lowest price in the last 30 days: 142,82 €

Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters Catalogue Number: Individual identification number assigned by the manufacturer. 002135732 Product Code: Product type as defined by the manufacturer. ETIMAT 10 3p C100 Class Name: Miniature circuit breakers are used to protect electrical…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 002135732 Category: EAN: 3838895328292 Brand:

Description

Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters

  • Catalogue Number:
  • Individual identification number assigned by the manufacturer. 002135732

  • Product Code:
  • Product type as defined by the manufacturer. ETIMAT 10 3p C100

  • Class Name:
  • Miniature circuit breakers are used to protect electrical installations in residential, public, and industrial buildings. Miniature Circuit Breaker

  • Rated Current [A]:
  • Value of current, established by the manufacturer, that the device can carry during continuous operation at a specified reference ambient air temperature. 100

  • Tripping Characteristic:
  • Miniature circuit breakers should have a tripping characteristic that ensures adequate circuit protection without premature or delayed tripping.
    Standardised instantaneous tripping ranges:
    – Type B (Above 3 In up to and including 5 In)
    – Type C (Above 5 In up to and including 10 In)
    – Type D (Above 10 In up to and including 20 In) C

  • Number of Poles:
  • Design version of the modular switching device: single-, double-, triple-, and four-pole. 3

  • Number of Modules:
  • Width of the device expressed as the number of standard 18 millimetre modules. 4.5

  • Short-Circuit Current [kA]:
  • Overcurrent that occurs in the event of a short circuit resulting from damage or improper connection in the electrical circuit. 10

  • Rated Voltage AC [V]:
  • The rated AC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 230/400

  • Rated Voltage DC [V]:
  • The rated DC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 60

  • Rated Frequency [Hz]:
  • The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60

  • Voltage Uimp [kV]:
  • Peak value of an impulse voltage of specified shape and polarity that an electrical device is able to withstand without damage under specified test conditions, to which the clearance values refer. 4

  • IP Protection Rating:
  • Degree of protection against access to hazardous parts and against the ingress of solid foreign objects and/or water, specified in accordance with EN 60529. IP20

  • Ambient Temperature [ËšC]
  • The temperature of the air surrounding the complete switching device under specified conditions. For switching devices installed inside an enclosure, this refers to the air temperature outside the enclosure. -25 to +55

  • Contact Gap [mm]:
  • The distance between the main contacts of the switching device in the open position, expressed in millimetres. >3

  • Conductor Connection Capacity [mm2]:
  • Size of the switch’s connection terminal allowing connection of a conductor with an appropriate cross-section, expressed in mm2. 2.5 – 50

  • Standards:
  • Standards according to which the device was designed, tested and certified. IEC/EN 60898-1,
    IEC 60947-2

  • Function:
  • Miniature circuit breaker, MCB (ang. miniature circuit breaker) MCB

    Product photo

    3D

    Product advantages

    • possibility of installing auxiliary contacts (PSM ETIMAT 80/125).
    • possibility of installing an undervoltage/shunt release (DA ETIMAT 80/125 110-415V).
    • possibility of supply from below or above.
    • possibility of double connection of the insulated pin-type busbar – top and bottom.
    • contact position indicator.
    • ability to seal the lever in the “On” and “Off” positions
    • Each circuit breaker marked with an EAN code.
    • Modern TH35 rail mounting method and easy replacement.

    Dimensional drawing

    ETIsON Curves

    Programme functionalities:

    • generating and plotting t/I characteristics of protective devices
    • adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
    • analysing selectivity between protective devices
    • simulating load or short-circuit response of protective devices
    • defining operating points and limit conditions from real applications
    • preparing reports for design documentation
    • Check how simple it is!

    Technical Data – Miniature Circuit Breaker

    Frequency50 Hz
    Voltage TypeAC
    Mounting Depth75 mm
    Rated Current100 A
    Frequency Range50 Hz
    Tripping CharacteristicC
    Rated insulation voltage Ui440 V
    Energy Limiting Class3
    Overvoltage Category3
    Pollution degree (N)3
    Protection Rating (IP)IP20
    Number of Protected Poles3
    Rated Short-Circuit Breaking Capacity according to EN 6089810 kA
    Rated short-circuit breaking capacity in accordance with IEC 60947-220 kA
    Ambient operating temperature-25 °C
    Number of Poles (Total)3
    Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V20 kA
    Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V20 kA
    Rated impulse withstand voltage Uimp4 kV

    Safety instructions: hilark.eu/gpsr/en.

    Additional information

    Weight0,71 kg
    Dimensions7,8 × 11 × 9,2 cm
    Brand

    ETI

    Length

    5 m

    Reviews

    There are no reviews yet.

    Be the first to review “ETI Miniature Circuit Breaker Etimat 10 C100 3-Pole 20 kA, 4.5 Modules”