F&F CKF-316 Phase Sequence and Failure Relay 10A 1P 1 Module, 3x400V/230V+N AC

21,18 € (17,22 € netto)

Lowest price in the last 30 days: 21,18 €

CKF-316 Phase Sequence and Phase Failure Sensor – Product Template – F&F Home and Industrial Automation CKF-316 Phase Sequence and Phase Failure Sensor CKF-316 Phase Sequence and Phase Failure Sensor for Motor Protection The CKF-316 is a phase control relay designed to protect electric motors powered from a 3 × 400 V + N three-phase mains supply. The device monitors voltage loss on any phase, voltage asymmetry between phases, exceeding permissible phase voltage values, and correct phase sequence, thereby reducing the risk of drive damage and unwanted reversal of rotation direction…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: CKF-316 Category: EAN: 5908312593164 Brand:

Description

CKF-316 Phase Sequence and Failure Sensor – Product Template – F&F home and industrial automation

CKF-316

CKF-316 Phase Sequence and Failure Sensor

Phase sequence and failure sensor for motor protection

The CKF-316 is a phase control relay designed to protect electric motors supplied from a three-phase 3 × 400 V + N network. The device monitors voltage loss in any phase, voltage asymmetry between phases, exceeding permissible phase voltage values, and correct phase sequence, thereby reducing the risk of drive damage and unwanted reversal of the motor’s direction of rotation. This is a practical solution for industrial automation, machine installations, control switchboards and drive systems requiring stable and safe operation. The sensor uses a fixed voltage asymmetry trip threshold of 55 V and a 5 V hysteresis, while the 4 s switch-off delay helps avoid unnecessary motor stoppage during brief voltage dips. In the event of phase loss, exceeded asymmetry or incorrect phase sequence, the device blocks motor start-up or disconnects it via a 1 × NO/NC relay contact. The CKF-316 supports protection of three-phase motors, phase sequence monitoring and power supply asymmetry protection in automation systems. As a product in the phase failure sensors and phase voltage sensors category, it helps increase installation reliability, improve operational safety and reduce downtime and repair costs. Mounting on a TH-35 DIN rail, a width of one module and screw terminals make it easy to integrate the device into standard switchboards.

Why choose the CKF-316?

Power supply 3 × 400 V + N

Phase failure and asymmetry monitoring

Phase sequence monitoring

Asymmetry threshold 55 V

Power consumption 1.6W

Switch-off delay 4 s

Isolated relay contact 1 × NO/NC

DIN TH-35 rail mounting

Single module width 18 mm

Motor protection against phase failure

The CKF-316 monitors the presence of voltage in each phase of the three-phase network. In the event of voltage loss in at least one phase, the device disconnects the motor, protecting the windings and reducing the risk of costly drive failure.

Fixed voltage asymmetry threshold

The sensor responds to voltage asymmetry exceeding 55 V, and automatic reconnection occurs once the asymmetry drops by the 5 V hysteresis value. This ensures stable control of supply conditions without the need for manual threshold adjustment.

Lock-out on incorrect phase sequence

The device detects an incorrect phase sequence that could cause a reversal of the motor’s direction of rotation. Blocking start-up until the correct sequence is restored increases the safety of machines and technological processes.

Reliable control

Monitors key three-phase power supply parameters.

Compact installation

Occupies a single module in the switchboard.

LED signalling

Enables quick assessment of operating status.

CKF-316 – device visualisation

Discover other advantages of the CKF-316

Modular 18 mm enclosure

The device has a compact enclosure, one module wide, designed for installation in a switchboard.

TH-35 rail mounting

The shape of the enclosure allows installation on a standard TH-35 rail used in modular equipment.

Screw terminals for conductors

Screw terminals for connecting phases, the neutral conductor and the relay contact are visible on the front of the enclosure.

Two LED signal indicators

The front panel is fitted with two LEDs indicating the power supply status and incorrect phase sequence.

Terminal markings on the enclosure

The enclosure features clear terminal markings, making it easier to identify phase paths and contacts.

Additional materials

See also: CKF-318, CZF-BT Phase Control Relays

See also: Video Tutorial Practical Electrician – CKF 318 – phase sequence sensor

HEAT PUMP PROTECTION

GUIDE

How to check the phase sequence in a three-phase low-voltage electrical installation

GUIDE

Diagrams

Dimensions Connection Diagram

Technical Parameters

With Removable Terminals No External Power Supply Required Yes Phase Sequence Control Yes Phase Failure Detection Yes Undervoltage Control Function Yes Overvoltage Control Function No Phase Asymmetry Control Yes Minimum Adjustable Delay on Power Failure 1 s Number of NO Contacts 0 Electrical Connection Type Screw Connection Supply Voltage for AC 50 Hz 150-280 V Minimum Adjustable Delay on Power-Up 4 s Maximum Allowable Delay on Power-Up 4 s Maximum Allowable Delay on Power Failure 1 s Number of NC Contacts 0 Number of CO Contacts 1 Operating Voltage for AC 50 Hz 150-280 V Rated Switching Current 10 A Supply Voltage Type AC Supply Voltage Type AC Depth 0 mm Height 0 mm Width 0 mm

Discover our other solutions!

CKF

CKF

With a fixed voltage asymmetry trip threshold.

1 x NO contact.

Sensor for phase sequence and phase failure designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor.

CKF-316-TRMS

CKF-316-TRMS

With a fixed voltage asymmetry trip threshold.

1 x NO/NC contact.

Application: for protecting electric motors powered from a three-phase mains supply.

The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-316-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction.

CKF-319-TRMS

CKF-319-TRMS

CKF-319 TrueRMS Phase Sequence and Phase Failure Sensor

For protecting electric motors powered from a three-phase mains supply.

The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-319-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction.

CKF-317-TRMS

CKF-317-TRMS

With an adjustable voltage asymmetry trip threshold.

1 x NO/NC contact.

The phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The sensor will trip when voltage is lost in at least one phase or when voltage asymmetry occurs between phases (risk of motor damage). The CKF-317-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction.

CKF-BR-TRMS

CKF-BR-TRMS

With an adjustable voltage asymmetry trip threshold.

1 x NO/NC contact.

The CKF-BR TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor. The CKF-BR-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction

CKF-B-TRMS

CKF-B-TRMS

With a fixed voltage asymmetry trip threshold.

1 x NO contact.

The CKF-B TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor.

CKF-BT-TRMS

CKF-BT-TRMS

With adjustable trip delay time. 1NO/NC contact.

The CKF-BT-TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-BT-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction.

CKF-TRMS

CKF-TRMS

With a fixed voltage asymmetry trip threshold.

1 x NO contact.

The CKF TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor.

Files to download

CKF-316-declaration-pref-origin-status-1.pdf CKF-316-declaration-RoHS-pl-1.pdf ckf-316-instrukcja-obslugi.pdf ckf-316-true-rms-instrukcja-obslugi.pdf ckf-316-schemat-cad-dxf.dxf ckf-czf-cp-deklaracja-ce-2025.pdf

About F&F

F&F is a Polish manufacturer of home and industrial automation with many years of experience. For years we have been delivering innovative, reliable and easy-to-use solutions that enhance comfort and safety in homes and production facilities. We design and manufacture our devices entirely in Poland, placing particular emphasis on quality, modern technologies and technical support for our customers.

Polish manufacturer of home and industrial automation

Technical Data – Phase Control Relay

Width0 mm
Height0 mm
Depth0 mm
Voltage Measurement Range190 V
Supply voltage typeAC
Type of Electrical ConnectionScrew Connection
Supply Voltage TypeAC
Rated Making Current10 A
Supply voltage for AC 50 Hz150 V
Maximum Allowable Delay on Power-Up4 s
Minimum Adjustable Delay on Power-Up4 s
Maximum Allowable Delay on Power Failure1 s
Minimum Adjustable Delay on Power Failure1 s
Operating voltage for AC 50 Hz150 V
Number of NC Contacts0
Number of NO Contacts0
Number of Changeover Contacts1

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,072 kg
Dimensions9,5 × 9,5 × 2 cm
Brand

F&F

Length

1 m

Rated Current

10 A

Number of Phases

Single Phase

Reviews

There are no reviews yet.

Be the first to review “F&F CKF-316 Phase Sequence and Failure Relay 10A 1P 1 Module, 3x400V/230V+N AC”

Your email address will not be published. Required fields are marked *