Siemens 3RV Auxiliary Contact 1NO+1NC, Side Mounting, Screw Terminals

6,91 € (5,62 € netto)

Lowest price in the last 30 days: 6,91 €

SIRIUS 3RV Circuit Breakers SIRIUS 3RV Circuit Breakers Safety You Can Afford Circuit breakers for your applications Motor circuit breakers and more SIRIUS 3RV is a series of circuit breakers most commonly used to protect motors. But that’s not all. Versions are also available with an overload relay function, for protecting star-delta starter combinations (without an overload element), for protecting transformers, for protecting installations (without load asymmetry monitoring), as well as versions compliant with UL 489. See which devices fall within the scope of SIRIUS 3RV circuit breakers Motor circuit breakers Equipped with a trip…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 3RV2901-1A Category: EAN: 4011209737075 Brand:

Description

SIRIUS 3RV Circuit Breakers

SIRIUS 3RV Circuit Breakers

Safety you can afford

Circuit breakers for your applications

Motor circuit breakers
and more

SIRIUS 3RV is a series of circuit breakers&nbspmost commonly used to protect motors.
But that’s not all. Versions are also available with&nbspan overload relay function, for protecting star-delta starter combinations (without&nbspan overload element), for protecting transformers, for protecting installations (without&nbspload asymmetry monitoring), as well as&nbspversions compliant with&nbspUL 489.

See&nbspwhich devices fall within the scope of&nbspSIRIUS 3RV circuit breakers

Motor circuit breakers Equipped with&nbspa short-circuit trip and overload trip, an overload trip detecting load asymmetry (phase loss), suitable for motors&nbspwith a rated current in&nbspthe range of 0.11…100 A. Breaking capacity Icu up to 100 kA. Dedicated to starting class 10 and&nbspin&nbspa narrower range, class 20. Thanks to a short-circuit trip set at 13 times the rated current, suitable for motors&nbspin&nbspIE 3 design.

Circuit breakers with&nbspan overload relay function Similar to standard motor circuit breakers, dedicated to protecting electric motors&nbspwith&nbspone difference – in&nbspthe event of overload, no tripping occurs; instead, the built-in contact switches. This version is suitable for use wherever stopping the electric motor&nbspdue to overload cannot be allowed.

Circuit breakers for protecting starter combinations Correct protection of a star-delta system requires the use of two devices. One performing the short-circuit protection function and&nbspthe second (on the side of one of the&nbspconductors&nbspsupplying the motor) performing the overload protection function. The 3RV23 series circuit breakers do not have a built-in overload trip, making them ideally suited for this task.

Circuit breakers for protecting transformers When switching on a transformer, the currents flowing through the&nbspprotective device are significantly higher than during motor starting. This can lead to a situation in&nbspwhich switching on is&nbspnot possible due to&nbspcontinuous tripping of the protective device. The 3RV24 series circuit breakers have been adapted for this task. Their short-circuit trip&nbspstarts operating at 20 times the rated current.

Circuit breakers compliant with&nbspUL 489 Special versions compliant with&nbspUL 789 / CSA C22.2 No. 5 dedicated to protecting installations and devices&nbspother than motors (3RV27) and&nbspinstallations and&nbsptransformers&nbspcharacterised by high inrush current (3RV28). At first glance, these versions are equipped with&nbspadditional insulating elements designed to extend air and creepage clearances.

3RV29 mounting system The 3RV29 mounting system significantly reduces the time required for switchgear prefabrication. It is available in&nbspversions dedicated to devices with&nbspscrew and/or spring terminals. Thanks to the use of dedicated connectors, errors that could occur with classic wiring are also significantly reduced.

Accessories Auxiliary and&nbspsignalling contact blocks, wireless communication module. Isolating module with&nbspa visible isolating gap, undervoltage or overvoltage releases. Three-phase power busbars, adapters for 60 mm&nbspdistribution rails, door operating mechanisms… thanks to the wide range of accessories, the 3RV series circuit breakers will meet every requirement.

Discover the benefits of&nbspusing SIRIUS 3RV circuit breakers

  • Reliable operation

    Motor circuit breakers are optimised for motor protection. Thanks to&nbspits design, the overload trip is&nbspable to protect the motor in&nbspthe event of phase loss and&nbspload asymmetry. The circuit breaker setting can be easily adjusted to&nbspcurrent installation conditions&nbsp– i.e. ambient temperature. It is&nbspalso worth noting that versions are available which can operate at&nbspan ambient temperature of -50°C.

  • Fast diagnostics

    Short circuit or overload? This information is quite important from&nbspthe point of view of ongoing maintenance. The circuit breaker’s trip mechanism is designed so that after it operates, the dial remains in&nbspthe intermediate (TRIP) position, while detailed information on the cause of tripping is available via an additional signalling contact&nbspblock.

  • Screw or spring terminals

    Devices and accessories are available in&nbspversions with&nbspscrew terminals or spring terminals. Spring terminals are available for devices up to&nbsp15 kW&nbsp(32 A). Ring terminals are also available, but they are not popular.

  • Compatibility with&nbspother devices

    SIRIUS components have been designed to work together as seamlessly as possible. The same applies in&nbspthis case. Motor circuit breakers can be easily combined with&nbsp3RT series contactors, 3RW&nbspsoft starters, and&nbspother devices from&nbspthe SIRIUS range.

  • Reliable
    operation

    Fast
    diagnostics

    Type of
    terminals

    Compatibility with other
    devices

See what questions other users have had

How to set a motor circuit breaker?

The overload trip setting value is set using the dial. The dial has a scaled correction for the installation method and ambient temperature.

Does the circuit breaker provide isolation from voltage?

In&nbspaccordance with&nbspthe requirements of EN 60204-1, the 3RV series circuit breakers are suitable for disconnection (isolation) from voltage. If a visible isolating gap is required, an additional isolating module can be used.

How to select a motor circuit breaker?

The circuit breaker should be safely selected at the middle of the overload trip range.

What is a starting class?

The starting class characterises the severity of starting. It defines the time interval within&nbspwhich the overload trip will operate when 7.2 times the setting current flows through a cold circuit breaker. For class 10, this is a time range of 4…10 s.

SIRIUS Industrial Switching Devices

Technical Data – Auxiliary Contact Block

Mounting MethodOther
Lamp holderNone
Rated operational current Ie for AC-15, 230 V4 A
Type of Electrical ConnectionScrew Connection
Number of fault signalling contacts0
Number of NC Contacts1
Number of NO Contacts1
Number of Changeover Contacts0

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,036 kg
Dimensions8,8 × 6,7 × 1 cm
Brand

Siemens

Rated Current

32 A

Reviews

There are no reviews yet.

Be the first to review “Siemens 3RV Auxiliary Contact 1NO+1NC, Side Mounting, Screw Terminals”

Your email address will not be published. Required fields are marked *