Legrand P312 DX3 RCBO C16 30 mA Type A 1P+N 6 kA, 2 Modules

65,99 € (53,65 € netto)

Lowest price in the last 30 days: 65,99 €

Residual current circuit breakers with overcurrent protection P 310, DX³ series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal alternating residual currents – Type A – detects sinusoidal alternating and pulsating direct residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Double pole 230 V~ Type A – Characteristic C – Rated residual current: 30 mA – Rated current: 16 A – Width in 17.5 mm modules: 2 – Mounting on TH35 rail – Can be connected using comb-type busbars or…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 411061 Category: EAN: 3414970351821 Brand:

Description

Residual current circuit breakers with overcurrent protection P 310, DX³ series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal alternating residual currents – Type A – detects sinusoidal alternating and pulsating direct residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Double pole 230 V~ Type A – Characteristic C – Rated residual current: 30 mA – Rated current: 16 A – Width in 17.5 mm modules: 2 – Mounting on TH35 rail – Can be connected using comb-type or pin-type busbars – Can be fitted with auxiliary contacts, trip units and drives from the DX³ series – Grey operating lever

Technical data – Residual current circuit breaker with overcurrent protection

Voltage TypeAC
Mounting Depth44 mm
Rated Current16 A
Rated Voltage230 V
Tripping CharacteristicC
Rated residual current0.03 A
SensitivityA
Surge current resistance0.25 kA
Energy Limiting Class3
Pollution degree (N)2
Width in Number of Modules2
Frequency50 Hz
Protection Rating (IP)IP20
Number of Protected Poles1
Rated short-circuit breaking capacity in accordance with IEC 60947-26 kA
Cross-section of connectable single-wire conductor0.75 mm2
Cross-section of connectable multi-wire conductor0.75 mm2
Number of Poles (Total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
Rated short-circuit breaking capacity according to EN 610096 kA

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,239 kg
Dimensions10,8 × 8,6 × 4,2 cm
Brand

Legrand

Length

2 m

Rated Current

16 A

Reviews

There are no reviews yet.

Be the first to review “Legrand P312 DX3 RCBO C16 30 mA Type A 1P+N 6 kA, 2 Modules”