Legrand ON300 Surge Arrester T2 C 4P 20 kA, 1.2 kV TT, TNC, TNS, 4 Modules
51,24 € (41,66 € netto)
ON 300 Surge Arresters – Protection against the effects of surges in 230/400 V~ power supply networks, 50/60 Hz – Compliant with IEC/EN 61643-11 – Type 2 (formerly Class C) – Recommended for installation in sub-distribution boards Surge Arrester Type 2 (formerly Class C): Standard arresters recommended for lower-power electrical installations: – Imax = 20 kA/pole (8/20 µs impulse) – In = 5 kA/pole – Maximum Voltage (Uc): 320 V~ – Protection Level (Up): 1.2 kV – For Network Type: TT, TNC, TNS – Technology Used: Varistor – Design: 4P – Recommended Overcurrent Protection: S 300…
Ships within 1 business day · delivery in approx. 3 business days
Description
ON 300 Surge Arresters – Protection against the effects of surges in 230/400 V~ power supply networks, 50/60 Hz – Compliant with IEC/EN 61643-11 – Type 2 (formerly Class C) – Recommended for installation in sub-distribution boards Surge Arrester Type 2 (formerly Class C): Standard arresters recommended for lower-power electrical installations: – Imax = 20 kA/pole (8/20 µs impulse) – In = 5 kA/pole – Maximum Voltage (Uc): 320 V~ – Protection Level (Up): 1.2 kV – For Network Type: TT, TNC, TNS – Technology Used: Varistor – Design: 4P – Recommended Overcurrent Protection: S 300 TX³/DX³ C 20A – Width in 17.5 mm Modules: 4 – With Replaceable Cartridges and Status Indicator: – green indicator: cartridge functional – orange indicator: cartridge requires replacement
ON300 surge protector series
Surges caused by lightning strikes are responsible for 25 to 40% of all electrical equipment damage. If we also take into account surges arising from other causes, it turns out that the installation of surge protective devices can prevent up to 60% of electrical equipment damage.
The effectiveness of installation protection through widespread use of surge protective devices is reflected in national standards and regulations. The new Legrand surge protectors provide a response to eliminating the effects of this hazard in any type of electrical installation and for any level of risk.
Technical Data – Class C Surge Arrester
| Mounting Method | 35 mm DIN Rail |
| Number of conductors (excluding earth) | 4 |
| Size | 4 modules |
| Protection level | 1.2 kV |
| Maximum continuous operating voltage AC | 320 V |
| Rated discharge current – peak value (8/20) | 5 kA |
| Rated voltage AC | 230 V |
| Operation indication on device | Optical |
| Protection Rating (IP) | IP20 |
| Max. conductor cross-section (solid/stranded) | 35 mm2 |
| Max. flexible conductor cross-section | 25 mm2 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,356 kg |
|---|---|
| Dimensions | 10 × 9 × 7,5 cm |
| Brand | Legrand |











Reviews
There are no reviews yet.