ETI Kzs-2M RCBO B10 30 mA Type AC 1P+N 10 kA, 2 Modules
31,09 € (25,28 € netto)
Reliable and proven KZS residual current circuit breakers with overcurrent protection The residual current circuit breaker with overcurrent protection is designed to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. It provides protection against short circuits and overloads in the protected electrical circuits. Residual current circuit breakers with overcurrent protection are used in TN-S, TN-C-S, TT and IT networks, where the neutral…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Reliable and proven KZS residual current circuit breakers with overcurrent protection The residual current circuit breaker with overcurrent protection is designed to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. It provides protection against short circuits and overloads in the protected electrical circuits. Residual current circuit breakers with overcurrent protection are used in TN-S, TN-C-S, TT and IT networks, where the neutral conductor and earthing are separated. Technical parameters
Individual identification number assigned by the manufacturer. 002173102
Product type as specified by the manufacturer. KZS-2M AC B10/0.03
The residual current circuit breaker with overcurrent protection is designed to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. It also provides protection against short circuits and overloads in the protected electrical circuits. Residual current circuit breaker with overcurrent protection
30
The value of current, established by the manufacturer, which the device can carry during continuous operation at a specified reference ambient air temperature. 10
– Type AC – sensitive to alternating residual current.
– Type A – sensitive to alternating and pulsating DC residual currents.
– Type A G/KV – sensitive to alternating and pulsating DC residual currents, with a guaranteed hold time of at least 10 ms; suitable for load circuits with high transient residual current.
– Type B (designation KZS-4M 2p) – sensitive to alternating, pulsating and smooth DC residual currents. Tripping values up to 1 kHz. AC
A residual current circuit breaker with overcurrent protection should have an operating characteristic that ensures adequate circuit protection without causing premature or delayed tripping.
Standardised instantaneous tripping ranges:
– Type B (Above 3 In up to and including 5 In)
– Type C (Above 5 In up to and including 10 In)
B
Overcurrent that occurs in the event of a short circuit resulting from damage or improper connection in the electrical circuit. 10
The rated AC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for its correct and safe operation. This value is specified by the device manufacturer and is taken into account during its design and use. 240
The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60
Instantaneous
The ambient air temperature around the complete switching device, specified under given conditions. For switching devices installed inside an enclosure, this is the air temperature outside the enclosure. -25 to 40
Design version of the given modular switching device: two-pole and four-pole. 2
Device width expressed in the number of standard 18 mm modules. 2
Size of the switching device’s connection terminal enabling connection of a conductor with the appropriate cross-section, expressed in mm2. 1 to 25
Right
The IP rating defines the degree of protection or tightness of an electrical device’s enclosure against the ingress of solid objects, water and dust, as well as against unintentional contact with components inside the enclosure. The IP classification complies with EN 60529. IP20
Residual current circuit breaker with overcurrent protection, RCBO (residual circuit breaker with overload) RCBO
Product photo
3D
Product advantages
- The “Test” button allows the user to check the correct operation of the circuit breaker.
- Indicator of the actual position of the main contacts for easier identification of whether the RCBO is in the ON or OFF position.
- Terminal protection against contact with live parts.
- The terminal design allows the use of insulated busbars on both the upper and lower terminals.
- “ON/OFF” marking on the switching lever.
- Possibility of sealing the lever in the “ON” and “OFF” positions.
- Possibility of mounting auxiliary contacts PS KZS-2M/4M (002159500).
Dimensional drawing
ETIsON Curves
Programme functionalities:
- generating and plotting t/I characteristics of protective devices
- adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
- analysing selectivity between protective devices
- simulating load or short-circuit response of protective devices
- defining operating points and limit conditions from real applications
- preparing reports for design documentation
Check how simple it is!
Technical data – Residual current circuit breaker with overcurrent protection
| Voltage Type | AC |
| Mounting Depth | 69 mm |
| Rated Current | 10 A |
| Rated Voltage | 230 V |
| Tripping Characteristic | B |
| Rated insulation voltage Ui | 500 V |
| Rated residual current | 0.03 A |
| Sensitivity | AC |
| Energy Limiting Class | 3 |
| Width in Number of Modules | 2 |
| Frequency | 50 Hz |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 1 |
| Cross-section of connectable single-wire conductor | 1 mm2 |
| Cross-section of connectable multi-wire conductor | 1 mm2 |
| Number of Poles (Total) | 2 |
| Rated short-circuit breaking capacity according to EN 61009 | 10 kA |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,25 kg |
|---|---|
| Dimensions | 9 × 3,7 × 7,5 cm |
| Brand | ETI |
| Length | 2 m |
| Rated Current | 10 A |