ETI Etitec ML T123 300/12,5 4+0 Surge Arrester T1+T2+T3 B+C+D 4P 1.5 kV TNS, 4 Modules

120,67 € (98,11 € netto)

Lowest price in the last 30 days: 120,67 €

Reliable and proven ETITEC ML surge arresters ETITEC ML T123 surge arresters are a versatile solution providing Type 1, Type 2 and Type 3 (B, C, D) protection in electrical installations. Designed for mounting in the main distribution board, they protect against overvoltages caused by direct and indirect lightning strikes as well as switching overvoltages. Technical Parameters Catalogue Number: Individual identification number assigned by the manufacturer. 002440667 Product Code: Product type as specified by the manufacturer. ETITEC ML T123 300/12.5 4+0 Type according to…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 002440667 Category: EAN: 3838895927174 Brand:

Description

Reliable and proven ETITEC ML surge arresters ETITEC ML T123 surge arresters are a versatile solution providing Type 1, Type 2 and Type 3 (B, C, D) protection in electrical installations. Designed for mounting in the main distribution board, they protect against overvoltages caused by direct and indirect lightning strikes as well as switching overvoltages. Technical Parameters

  • Catalogue Number:
  • Individual identification number assigned by the manufacturer. 002440667

  • Product Code:
  • Product type as specified by the manufacturer. ETITEC ML T123 300/12.5 4+0

  • Type according to EN/IEC:
  • Type T1, T2 and T3 (I, II, III) arresters are a universal solution designed to protect against overvoltages caused by direct, indirect or switching lightning strikes. T1, T2, T3,
    I, II, III

  • Maximum Continuous Operating Voltage Uc [V]:
  • Maximum voltage that may be continuously applied to the surge arrester without triggering operation 300

  • Rated Voltage Un [V]:
  • Standard voltage for which the device is designed to operate. 230

  • Temporary Overvoltage TOV UT:
  • TOV (Temporary OverVoltage) refers to transient overvoltages with elevated voltage levels. They occur, for example, due to loss of the neutral conductor, network asymmetry, or improper equipment operation. 442V/120min
    safe disconnection

  • Rated Impulse Current 10/350μs Iimp [kA]:
  • Surge current value with a specified pulse shape (10/350 μs) that the device can repeatedly discharge. 12.5

  • Rated Discharge Current 8/20μs In [kA]:
  • Discharge current with an 8/20 μs pulse that the device can withstand repeatedly during normal operation. 20

  • Maximum Discharge Current 8/20μs Imax [kA]:
  • The highest impulse current (8/20μs) that the device can discharge once without damage. 40

  • Voltage Protection Level Up [kV]:
  • Maximum voltage that appears at the arrester’s output during operation <1.5

  • Follow Current Ifi:
  • Maximum current that may flow through the arrester after operation, before it is automatically disconnected from the network. Varistor-based arresters do not generate follow current. none

  • Specific Energy W/R [kJ/Ω]:
  • A measure of the energy dissipated by the device relative to its resistance – important for assessing durability. 39

  • Internal Thermal Protection:
  • An integrated system that disconnects the arrester from the installation in the event of overheating, preventing damage or fire. yes

  • Backup Fuse Required if Main Protection is > 160A:
  • Indicates that additional protection is required when the main protection current exceeds 160 A. 160A gG (max.)

  • IP Protection Rating:
  • Enclosure protection rating indicating resistance to ingress of solid objects and water. IP20

  • Protective Element Technology:
  • Indicates the type of internal component used in the surge arrester. In low-voltage technology, three main types are used: varistors (MOV), spark gaps (GDT), and combined (MOV+GDT). MOV

  • Number of Poles:
  • Surge arresters are available in 1, 2, 3 or 4-pole versions. 4

  • Number of Modules:
  • Width of the device expressed in the number of standard 18 mm modules. 4

  • Internal Configuration:
  • The first digit in the designation 1+0, 2+0, etc. indicates the number of modules with varistors, the second digit 1 indicates an N-PE pole with a spark gap. 4+0

    Product photo

    3D

    Product advantages

    • Each surge arrester includes thermal protection that disconnects it from the network if the current exceeds the maximum permissible value (Imax).
    • Made with high-quality varistors.
    • The designation includes key technical parameters and connection details, including maximum conductor cross-sections: 35 mm² (solid) and 25 mm² (stranded).
    • Varistor condition indicator: red – damaged, green – functional.
    • All surge arresters feature positioning elements that prevent improper installation of modules from a different surge arrester.
    • All surge arresters allow quick module replacement. A locking latch prevents accidental removal and increases vibration resistance.
    • A double earthing terminal allows for an additional earth conductor connection.
    • Quick-mount latch for DIN rail installation.
    • Removable self-locking contacts for remote fault signalling (RC). Only for type ETIETC ML T123 300/12.5…RC
    • When using multiple single-pole surge arresters, it is possible to simultaneously connect busbars and conductors from the top and bottom.

    Dimensional drawing

    Internal circuits ETITEC ML T123 300/12.5 RC

    ETIsON Curves

    Programme functionalities:

    • generating and plotting t/I characteristics of protective devices
    • adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
    • analysing selectivity between protective devices
    • simulating load or short-circuit response of protective devices
    • defining operating points and limit conditions from real applications
    • preparing reports for design documentation
    • Check how simple it is!

    Technical data – Class B+C surge arrester

    Mounting Method35 mm DIN Rail
    Number of poles4
    Size4 modules
    Maximum continuous operating voltage AC300 V
    Rated voltage AC230 V
    Rated voltage DC0 V
    Network systemTN network
    Protection classType 1+2
    Operation indication on deviceOptical
    Maximum continuous operating voltage DC0 V
    Protection Rating (IP)IP20
    Max. conductor cross-section (solid/stranded)35 mm2
    Max. flexible conductor cross-section25 mm2
    Specific energy (W/R)39

    Safety instructions: hilark.eu/gpsr/en.

    Additional information

    Weight0,564 kg
    Dimensions8 × 11 × 10 cm
    Brand

    ETI

    Reviews

    There are no reviews yet.

    Be the first to review “ETI Etitec ML T123 300/12,5 4+0 Surge Arrester T1+T2+T3 B+C+D 4P 1.5 kV TNS, 4 Modules”

    Your email address will not be published. Required fields are marked *