ETI EFI-P4 RCCB 63A 4P 100 mA Type A 10 kA, 4 Modules

56,25 € (45,73 € netto)

Lowest price in the last 30 days: 56,25 €

Reliable and proven EFI residual current circuit breakers The residual current circuit breaker is used to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. Residual current circuit breakers are used in TN-S, TN-C-S, TT and IT networks, where the neutral conductor and earth are separated. For protection against indirect contact with live parts (fault protection), it is recommended to use residual current circuit breakers with a residual current I Δn…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 002061523 Category: EAN: 3838895866404 Brand:

Description

Reliable and proven EFI residual current circuit breakers The residual current circuit breaker is used to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. Residual current circuit breakers are used in TN-S, TN-C-S, TT and IT networks, where the neutral conductor and earth are separated. For protection against indirect contact with live parts (fault protection), it is recommended to use residual current circuit breakers with a residual current IΔn≤ 300 mA. For protection against direct contact with live parts (additional protection), it is recommended to use residual current circuit breakers with a residual current IΔn≤ 30 mA. To ensure fire protection in accordance with DIN VDE 0100-482 and IEC 60364-4-482 standards, all cables and cores in TN and TT systems must be protected using residual current circuit breakers with a residual current IΔn≤ 300 mA. In installations where an excessive increase in resistance may cause a fire (ceiling infrared heaters with heating panels), the rated residual current value must be IΔn= 30 mA. Technical parameters

  • Catalogue Number:
  • Individual identification number assigned by the manufacturer. 002061523

  • Product Code:
  • Product type specified by the manufacturer. EFI-P4 A 63/0.1

  • Class Name:
  • The residual current circuit breaker is used to protect against electric shock resulting from direct or indirect contact with live parts, as well as to protect equipment against potential fire hazards caused by insulation damage. Residual current circuit breaker

  • Rated residual current (mA):
  • 100

  • Rated current (A):
  • Value of current, determined by the manufacturer, that the device can conduct during continuous operation at a specified reference ambient air temperature. 63

  • Type:
  • – Type AC – sensitive to alternating residual current.
    – Type A – sensitive to alternating residual currents and pulsating DC residual currents.
    – Type A S – sensitive to alternating residual currents and pulsating DC residual currents, with a guaranteed holding time of at least 40 ms; ensuring selectivity of operation with instantaneous or short-time-delay circuit breakers.
    – Type A G/KV – sensitive to alternating residual currents and pulsating DC residual currents, with a guaranteed holding time of at least 10 ms; suitable for load circuits with high transient residual current.
    – Type F – Type F circuit breakers are Type A circuit breakers with extended residual current detection capability. They correctly detect a DC component of up to 10 mA (Type A: 6 mA). In addition, they are capable of detecting distorted residual current containing higher harmonics.
    – Type B – sensitive to alternating, pulsating and smooth DC residual currents. Tripping values up to 1 kHz.
    – Type B+ – sensitive to alternating, pulsating and smooth DC residual currents. Tripping values up to 20 kHz and below 420 mA.
    – Type eV – EV series residual current circuit breakers are equipped with an active, mains-voltage-dependent function for detecting smooth DC residual currents with a tripping threshold of 6 mA. This prevents possible pre-magnetisation of a Type A residual current circuit breaker caused by smooth DC residual current, so that the device can continue to perform its protective function. These devices are intended solely for use in electric vehicle charging stations in accordance with DIN VDE 0100-722. RCCBs in EV design must not be used as a substitute for Type B or B+ residual current circuit breakers. A

  • Conditional short-circuit withstand capacity (kA):
  • Maximum conditional overcurrent value flowing through the current paths of the residual current circuit breaker when backed up by a suitable gG-type fuse link, occurring in the event of a short circuit resulting from a fault or incorrect connection in the electrical circuit. 10

  • Rated AC voltage (V):
  • The rated AC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for its proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 400

  • Rated frequency (Hz):
  • The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60

  • Tripping time:
  • Instantaneous

  • Ambient temperature (˚C):
  • The ambient air temperature around the complete switching device, specified under given conditions. For switching devices installed inside an enclosure, this is the air temperature outside the enclosure. -25 to 55

  • Number of Poles:
  • Design version of the given modular switching device: two-pole and four-pole. 4

  • Conductor connection capacity (mm2):
  • The size of the connection terminal of the switching device, allowing for the connection of a conductor with an appropriate cross-section, expressed in mm2. 1 – 25

  • N pole side:
  • Right

  • IP Protection Rating:
  • The IP rating defines the degree of protection or tightness of an electrical device’s enclosure against the ingress of solid objects, water and dust, as well as against unintentional contact with components inside the enclosure. The IP classification complies with EN 60529. IP20

  • Function:
  • Residual current circuit breaker, RCCB (residual current circuit breaker) RCCB

    Product photo

    3D

    Product advantages

    • The quality and reliability of every EFI-P residual current circuit breaker produced is ensured by a fully automated production line.
    • Every circuit breaker has a QR code containing technical and production data, as well as information from individual measurement tests.
    • The “Test” button allows the user to check the correct operation of the circuit breaker.
    • Indicator of the actual position of the main contacts for easier identification of whether the RCCB is in the ON or OFF position.
    • Terminal protection against contact with live parts.
    • The terminal design allows the use of insulated busbars on both the upper and lower terminals.
    • Possibility of sealing the lever in the “ON” and “OFF” positions.
    • Possibility of installing additional accessories (auxiliary contacts, trip units, etc.)
    • RESET version: in the event of a residual current, the lever moves to the middle “TRIP” position. In the event of manual switching off, the lever moves to the “OFF” position.
    • NL version: version of the circuit breaker with the N (neutral) pole located on its left-hand side.

    Installation of EFI-P residual current circuit breakers

    How are EFI-P residual current circuit breakers assembled?

    See the innovative ETI residual current circuit breaker production line.

    Dimensional drawing

    Types of residual current circuit breakers

    ETIsON Curves

    Programme functionalities:

    • generating and plotting t/I characteristics of protective devices
    • adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
    • analysing selectivity between protective devices
    • simulating load or short-circuit response of protective devices
    • defining operating points and limit conditions from real applications
    • preparing reports for design documentation
    • Check how simple it is!

    Technical data – Residual current circuit breaker

    Mounting Depth68 mm
    Rated Current63 A
    Rated insulation voltage Ui440 V
    Number of poles4
    SensitivityA
    Short-circuit withstand strength (Icw)10 kA
    Width in Number of Modules4
    Frequency50/60 Hz
    Protection Rating (IP)IP20

    Safety instructions: hilark.eu/gpsr/en.

    Additional information

    Weight0,2 kg
    Dimensions4 × 2 × 2 cm
    Brand

    ETI

    Rated Current

    63 A