Eaton xPole Home HNC-63/2/003 RCCB 63 A 2P 30 mA Type AC 6 kA, 2 Modules
43,71 € (35,54 € netto)
Eaton Residual Current Circuit Breaker 2P 63A 0.03A Type AC xPole Home HNC-63/2/003 194692 Key Product Features Residual current circuit breaker 2P 63A 0.03A Type AC xPole Home HNC‑63/2/003 194692 is dedicated to three-phase electrical installations in construction and industry. Protection against AC residual current faults Dual terminals (cage/rail) on top and bottom Additional protection against electric shock in accordance with EN HD 60364-4-41 Contact position indicator, red/green colour Testing required every 6 months instead of every month Mandatory element of the electrical installation…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton Residual Current Circuit Breaker 2P 63A 0.03A Type AC xPole Home HNC-63/2/003 194692 Key Product Features Residual current circuit breaker 2P 63A 0.03A Type AC xPole Home HNC‑63/2/003 194692 is dedicated to three-phase electrical installations in construction and industry. Protection against AC residual current faults Dual terminals (cage/rail) on top and bottom Additional protection against electric shock in accordance with EN HD 60364-4-41 Contact position indicator, red/green colour Testing required every 6 months instead of every month Mandatory element of the electrical installation in your home
Protection against electric shock The residual current circuit breaker (RCD), also known as an RCD device, is designed for three-phase installations in residential and commercial buildings. It provides effective protection against: FIRE | EQUIPMENT DAMAGE | ELECTRIC SHOCK Why is the Eaton xPole Home residual current circuit breaker a good choice? Simplified design A thoughtful and aesthetic appearance of the device ensures convenient operation without disrupting the interior décor. Resistance and durability against harsh environments A thoughtful and aesthetic appearance of the device ensures convenient operation without disrupting the interior décor. Compatibility with other devices The new EATON modular line allows integration with additional accessories, such as auxiliary contacts, trip units (overvoltage and undervoltage), automatic reclosers, connection busbars, or padlock locks. Easy installation in existing wiring systems Possibility of using EVG busbars for 12 modules or 1 m Z‑GV busbars, which streamlines the prefabrication process. Clear indicators signalling the operating status of the device Contact position indicators integrated with the mechanism, providing the user with information on the actual contact position. Protection against conductor contact Proper insulation thanks to a large distance between contacts, exceeding 4mm. Easy to install, convenient to use
Device status information at your fingertips Cage and rail terminal Grey lever mechanically linked to the ON/OFF indicator Possibility of sealing in the ON and OFF position Contact position indicator, red/green Simple installation on a DIN rail Technical specification:
- Model: HNC-63/2/003
- Protection Rating (IP): IP20
- Rated residual current [A]: 0.03
- Installation depth [mm]: 69.5
- Rated short-circuit capacity [kA]: 0.6
- Width expressed as number of modules: 2
- Enclosure size (in accordance with DIN 43880): 1
- Mounting method: DIN rail
- Sensitivity: AC
- Number of poles: 2
- Rated Current [A]: 63
- Surge current resistance [kA]: 0.25
- Short-circuit withstand capacity (Icw) [kA]: 6
Residual current device (RCD) for protection of people, equipment and installations Residual current devices
in electrical installations A residual current circuit breaker (RCD) is designed to cut off power supply when there is a risk of electric shock anywhere in the installation. The most commonly used types are AC and A. Where are RCDs used? Residential premises Industry Hospitals Public facilities The circuit breaker is mounted on a TH-35 type mounting rail The circuit breaker is mounted on a TH-35 type rail, and the device operates regardless of its orientation (vertical or horizontal).
- Dual terminals (cage/rail) at the top and bottom
- The busbar can be mounted at the top and bottom of the device
- Free cage terminal despite the installed busbar
- Possibility of later installation of the ZP-NHK auxiliary contact for trip signalling
- Possibility of later installation of the Z-HK auxiliary contact
The next stage in the development of protection devices EATON AFDD+ is not just an improved version of previous models. It is a modern step forward in the development of protective devices, utilising advanced technologies and digital innovations. HN
overcurrent circuit breakers
- Protection against short circuits and overload
- Basic fire protection
HNC
residual current circuit breakers
- Earth fault protection
- Basic fire protection
- Protection against electric shock
HNB
combined circuit breakers
- Earth fault protection
- Protection against short circuits and overload
- Enhanced fire protection
AFDD+ arc fault
detection device
- Arc fault protection
- Earth fault protection
- Protection against short circuits and overload
Frequently Asked Questions What is a residual current circuit breaker? A residual current circuit breaker, also known as an RCD, is a protective component in an electrical installation designed to protect users against electric shock. When should a residual current circuit breaker be used? Its use is required in consumer installations, particularly where the PEN conductor has been split into separate PE and N conductors. Which type of residual current circuit breaker should be chosen? The choice depends on the type of devices connected to the installation. For standard sockets and lighting, Type AC is sufficient, while in the presence of electronic and power electronic devices, Type A or F circuit breakers are recommended. Is the installation of an RCD mandatory? Yes – in accordance with building regulations, the use of residual current circuit breakers in electrical installations is mandatory. Why does the residual current circuit breaker trip? The device responds to leakage current, i.e. a situation where part of the current flows outside the protected circuit – this may indicate electric shock or insulation damage. In which situations does the RCD not protect against electric shock? Protection against direct contact is only effective for circuit breakers with a sensitivity of up to 30mA and circuits not exceeding 32A. At higher residual current values, such protection is not guaranteed. How does a residual current circuit breaker work? The device analyses the balance between the current flowing into and out of the circuit. In the event of a difference – indicating a potential current leakage – it automatically switches off. How to correctly connect a residual current circuit breaker? Installation should be carried out in accordance with the manufacturer’s instructions and performed by a qualified electrician. Residual current circuit breaker with overcurrent protection Residual current circuit breakers with overcurrent protection, also known as combined devices, combine the functions of an RCD and a miniature circuit breaker. In the EATON range, such devices can be found in the HNB and PKNM series. Is there a residual current circuit breaker that protects against fire? Yes, in accordance with EN HD 60364-4-42, RCDs with a sensitivity of up to 300mA can serve a fire protection function. Example models include PF6‑40/4/03 and PFIM‑63/4/03‑S/F.
Technical data – Residual current circuit breaker
| Mounting Method | DIN rail |
| Voltage Type | AC |
| Mounting Depth | 45 mm |
| Rated Current | 63 A |
| Rated Voltage | 230 V |
| Rated insulation voltage Ui | 440 V |
| Number of poles | 2 |
| Rated residual current | 0.03 A |
| Sensitivity | AC |
| Short-circuit withstand strength (Icw) | 6 kA |
| Surge current resistance | 0.25 kA |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 2 |
| RAL number (approximate) | 7035 |
| Frequency | 50 Hz |
| Protection Rating (IP) | IP20 |
| Cross-section of connectable single-wire conductor | 1.5 mm2 |
| Cross-section of connectable multi-wire conductor | 1.5 mm2 |
| Ambient operating temperature | -25 °C |
| Rated impulse withstand voltage Uimp | 4 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,22 kg |
|---|---|
| Dimensions | 7,3 × 8,5 × 3,5 cm |
| Brand | Eaton |
| Length | 1 m |
| Rated Current | 63 A |