Eaton xPole Home HNC-25/2/003-A RCCB 25 A 2P 30 mA Type A 6 kA, 2 Modules
34,51 € (28,06 € netto)
Eaton Residual Current Circuit Breaker 2P 25A 0.03A type A xPole Home HNC-25/2/003-A 194684 Main Product Features The Eaton residual current circuit breaker has been designed for three-phase electrical installations used in industrial facilities and residential buildings. Protection against alternating (AC) and pulsating (A) residual current shock Double terminals (cage/rail) on top and bottom Supplementary protection against electric shock in accordance with EN‑HD 60364‑4‑41 Contact position indicator, red/green colour Testing required every 6 months, not every month A mandatory element…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton Residual Current Circuit Breaker 2P 25A 0.03A type A xPole Home HNC-25/2/003-A 194684Main Product FeaturesThe Eaton residual current circuit breaker has been designed for three-phase electrical installations used in industrial facilities and residential buildings.Protection against alternating (AC) and pulsating (A) residual current shockDouble terminals (cage/rail) on top and bottomSupplementary protection against electric shock in accordance with EN‑HD 60364‑4‑41Contact position indicator, red/green colourTesting required every 6 months, not every monthA mandatory element of the electrical installation in your home
Protection Against Electric ShockThe Residual Current Device (RCD), also known as a residual current circuit breaker, is designed for three-phase installations in residential construction and commercial buildings.It provides effective protection against:FIRE | EQUIPMENT DAMAGE | ELECTRIC SHOCK Why is the residual current circuit breaker from Eaton xPole Home a good choice? Simplified designThe well-thought-out and aesthetic appearance of the device ensures convenient operation without disturbing the interior decor.Resistance and durability against harsh environmentsThe well-thought-out and aesthetic appearance of the device ensures convenient operation without disturbing the interior decor.Compatibility with other devicesThe new EATON modular line enables integration with additional accessories, such as auxiliary contacts, trip units (overvoltage and undervoltage), automatic reclosers, busbars or padlock locks.Easy installation in your existing wiringPossibility of using EVG busbars for 12 modules or Z‑GV busbars 1 m long, which streamlines the prefabrication process.Clear indicators signalling the device’s operating stateContact position indicators integrated with the mechanism, giving the user information about the actual position of the contacts.Safety against contact with conductorsProper insulation, thanks to a large distance between contacts of over 4mm. Easy to install, convenient to use
Device Status Information at Your FingertipsCage and rail terminalGrey lever mechanically linked to the ON/OFF indicatorCan be sealed in the ON and OFF positionRed/green contact position indicatorSimple installation on a DIN railTechnical Specification:
- Model: HNC-25/2/003-A
- Protection Rating (IP): IP20
- Rated residual current [A]: 0.03
- Installation depth [mm]: 69.5
- Rated short-circuit capacity [kA]: 0.5
- Width in number of modules: 4
- Enclosure size (in accordance with DIN 43880): 1
- Mounting method: DIN rail
- Sensitivity: AC
- Number of poles: 4
- Rated Current [A]: 40
- Surge current resistance [kA]: 0.25
- Short-circuit withstand capacity (Icw) [kA]: 6
Residual current device (RCD) for the protection of people, equipment and installationsResidual current devices
in electrical installationsThe residual current device (RCD) is designed to cut off power supply when there is a risk of electric shock in any part of the installation. The most commonly used types are type AC and type A.Where are RCDs used?Residential buildingsIndustryHospitalsPublic facilitiesThe device is mounted on a TH-35 type mounting railThe device is mounted on a TH-35 type rail and operates regardless of its orientation (vertical or horizontal).
- Dual terminals (cage/rail) at the top and bottom
- The busbar can be mounted at the top and bottom of the device
- Free cage terminal despite the installed busbar
- Possibility of later installation of the ZP-NHK auxiliary contact for trip signalling
- Possibility of later installation of the Z-HK auxiliary contact
The next stage in the development of protection devicesEATON AFDD+ is not just an improved version of previous models. It is a modern step in the development of protective devices, utilising advanced technology and digital innovation.HN overcurrent
circuit breakers
- Protection against short circuits and overload
- Basic fire protection
HNC residual current
circuit breakers
- Earth fault protection
- Basic fire protection
- Protection against electric shock
HNB combined
circuit breakers
- Earth fault protection
- Protection against short circuits and overload
- Enhanced fire protection
AFDD+ arc fault
detection device
- Arc fault protection
- Earth fault protection
- Protection against short circuits and overload
Frequently asked questions What is a residual current device?The residual current device (RCD) is a protective component in an electrical installation, designed to protect users against electric shock.When should a residual current device be used?Its use is required in consumer installations, especially where the PEN conductor has been split into separate PE and N conductors.Which type of residual current device should I choose?The choice depends on the type of equipment connected to the installation. For standard sockets and lighting, a type AC device is sufficient, while in the presence of electronic and power electronic equipment, type A or F devices are recommended.Is the installation of an RCD mandatory?Yes – in accordance with building law regulations, the use of residual current devices in electrical installations is mandatory.Why does the residual current device trip?The device responds to leakage current, i.e. a situation where part of the current flows out of the protected circuit – this may indicate an electric shock or damaged insulation.In what situations does an RCD not protect against electric shock?Protection against direct contact is only effective for devices with a sensitivity of up to 30mA and circuits not exceeding 32A. At higher residual current values, such protection is not guaranteed.How does a residual current device work?The device monitors the balance between the current flowing in and out of the circuit. In the event of a difference – indicating potential current leakage – it automatically switches off.How to correctly connect a residual current device?Installation should be carried out in accordance with the manufacturer’s instructions and performed by a qualified electrician.Residual current device with overcurrent protectionResidual current devices with overcurrent protection, also known as combined devices, combine the functions of an RCD and an MCB. In the EATON range, such devices can be found in the HNB and PKNM series.Is there a residual current device that protects against fire?Yes, in accordance with EN 60364-4-42, RCDs with a sensitivity of up to 300mA can serve a fire protection function. Example models include PF6-40/4/03 and PFIM-63/4/03-S/F.
Technical data – Residual current circuit breaker
| Mounting Method | DIN rail |
| Voltage Type | AC |
| Mounting Depth | 45 mm |
| Rated Current | 25 A |
| Rated Voltage | 230 V |
| Rated insulation voltage Ui | 440 V |
| Number of poles | 2 |
| Rated residual current | 0.03 A |
| Sensitivity | A |
| Short-circuit withstand strength (Icw) | 6 kA |
| Surge current resistance | 0.25 kA |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 2 |
| RAL number (approximate) | 7035 |
| Frequency | 50 Hz |
| Protection Rating (IP) | IP20 |
| Cross-section of connectable single-wire conductor | 1.5 mm2 |
| Cross-section of connectable multi-wire conductor | 1.5 mm2 |
| Ambient operating temperature | -25 °C |
| Rated impulse withstand voltage Uimp | 4 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,208 kg |
|---|---|
| Dimensions | 8,5 × 7,5 × 3,5 cm |
| Brand | Eaton |
| Length | 1 m |
| Rated Current | 32 A |












Reviews