Eaton PKZM0-25.0-EA Thermal-Magnetic Motor Protective Circuit Breaker 20.0-25.0 A 3NO 12.5 kW 2.5M 50 kA, Rotary Operator, Screw Terminals
72,16 € (58,67 € netto)
Eaton 1.0 189869 {{ $code_optional }} 4015081878659 2025-08-07 Motor Protective Circuit Breaker for Transformers PKZM0-25-EA Screw Terminals 189869 Main Product Features Compliance with IEC/EN60947 Screw Terminals Protection Rating IP20 Quick, Easy and Safe Installation Possibility of Connection to the MSFA Adapter PKZ Circuit Breakers – Tradition and Innovation Since 1932 Eaton has been manufacturing PKZ motor protective circuit breakers since 1932. For decades, our innovative solutions have had a significant impact on the development of motor protection technology. The PKZ brand has earned…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton 1.0 189869 {{ $code_optional }} 4015081878659 2025-08-07 Motor Protective Circuit Breaker for Transformers PKZM0-25-EA
Screw Terminals 189869 Main Product Features Compliance with IEC/EN60947 Screw Terminals Protection Rating IP20 Quick, Easy
and Safe Installation Possibility
of Connection to the
MSFA Adapter PKZ Circuit Breakers – Tradition and Innovation Since 1932 Eaton has been manufacturing PKZ motor protective circuit breakers since 1932. For decades, our innovative solutions have had a significant impact on the development of motor protection technology. The PKZ brand has earned a reputation not only as a symbol of high quality, but also as a synonym for motor protective circuit breakers among specialists. PKZ devices are modern, fuseless solutions that combine short-circuit and overload protection functions. Designed with Safety and Ease of Use in Mind PKZ motor protective circuit breakers provide both short-circuit and overload protection in a single, compact design. They are offered in two variants covering the full current range from 0.1 A to 63 A – in just 18 models, which translates into storage space savings and simplifies installation design. In addition, PKZ circuit breakers are fully compatible with Eaton’s DILM contactor series. Various Wiring Options ‑ Screw and Push‑in Motor protective circuit breakers can be connected not only traditionally using screws, but also using modern Push-in plug-in technology. Thanks to these terminals, cables can be connected quickly and safely with a single click – without the need for tools. This solution can reduce wiring time by up to 50% and ensures greater reliability thanks to resistance to vibration and shocks. PKZ circuit breakers equipped with Push-in terminals are available for rated currents up to 32 A. A version combining screw and plug-in terminals is also available, designed for use with three-phase power bridges. Certificates DISCOVER ACCESSORIES FOR PKZ Circuit Breakers 1 2 3 1 DISCOVER ACCESSORIES FOR PKZ Circuit Breakers 1Standard Auxiliary Contact (NHI) 2Auxiliary Contact Indicating Tripping (AGM) 3Overcurrent Release A‑PKZ0, Undervoltage Release U‑PKZ0 Greater Safety and Easier Selection of Solutions Use the online motor starter configurator to easily select the appropriate contactors, circuit breakers, and overload relays for direct-on-line, reversing, and star-delta starting systems. PKZ – a Key Component of the xStart System With just two circuit breaker models, it is possible to cover the entire current range from 0.1 A to 63 A, using only 20 device variants. Compatibility with the DIL contactor series enables quick and convenient assembly of complete motor starters. Ready for IE3 Motors The PKZM0, PKZM4, and PKE models have been tested for compatibility with energy-efficient IE3 motors. They offer reliable switching and effective protection against overloads and short circuits. Optimised response times of the short-circuit releases eliminate the risk of unnecessary tripping at higher starting currents, thereby ensuring stable operation.
SmartWire-DT – intelligent connection and monitoring The SmartWire-DT system increases the reliability and efficiency of drives, offering full data transparency in the immediate vicinity of the circuit breaker. Modular COM circuits enable monitoring of multiple parameters, including the current operating current in PKE models. This information is transmitted directly to the controller and available throughout the installation. Technical specification: Rated operating voltage Un: up to 690 V AC and up to 250 V DC Rated impulse withstand voltage Uimp: 6000 VAC Rated frequency: 50‑60 Hz Mounting method: on DIN rail Connection terminals: screw Terminal protection rating: IP00 Device protection rating: IP20 Operating temperature: ‑25°C to +55°C Storage temperature: ‑40°C to +80°C Phase failure sensitivity in accordance with IEC/EN 60947‑4‑1, VDE 0660 Part 102 Compliant with IEC 60947‑4‑1 and VDE 0660 Certificates: CE, UL, CSA, EAC Modern and safe technology PKZ motor protective circuit breakers are safe, modern fuseless solutions that combine overload and short-circuit protection functions in a single housing. The PKZM0, PKZM01, PKZM4 and PKE models are compatible with the same accessories, which significantly simplifies configuration. They can also be easily integrated with DILM contactors and DS7 soft starters. High quality and flexibility of application Eaton’s range includes a rich assortment of professional electrical installation products that form a complete system facilitating quick and convenient installation — ideal for installers who value reliability and functionality. Frequently Asked Questions What are motor protective circuit breakers and what are they used for? Motor protective circuit breakers are protective devices whose main task is to protect electric motors against overloads, short circuits and the loss of one phase. They are used in many industrial sectors where the safety and reliability of machine operation are crucial. Why choose PKZ motor protective circuit breakers? PKZ circuit breakers work excellently with energy-efficient IE3 class motors. They effectively handle high starting currents, offering reliable protection against overloads and short circuits, which translates into long-term and stable device operation. How does a transformer protective circuit breaker work and what functions does it perform? A transformer protective circuit breaker is responsible for monitoring the current flowing through the transformer. If a short circuit or overload is detected, it automatically interrupts the power supply circuit, protecting the device from damage. Its key tasks are protection against overload, short circuit, and responding to faults in one of the phases. Which standards do Eaton’s PKZ circuit breakers comply with? PKZ devices comply with the international standards VDE 0660 and IEC/EN 60947, confirming their high standard of quality and safety. What are the available current and operating voltage ranges for PKZ models? PKZ circuit breakers have an operating current range from 0.16 A to 32 A and operating voltages up to 690 V, making them versatile and suitable for use in various industrial applications. What conditions must be met when installing PKZ circuit breakers? PKZ circuit breakers can be mounted on DIN rails (top-hat rail) in accordance with IEC/EN 60715. They are also available in versions with push‑in terminals, which makes installation easier and faster and ensures a secure electrical connection. What are the main features and advantages of Eaton circuit breakers with push‑in terminals? Eaton circuit breakers equipped with Push-in terminals enable quick and simple installation, guaranteeing durable electrical connections without the need for tools. This solution streamlines the installation process and minimises the possibility of installation errors.
Technical Data – Motor Protection Circuit Breaker
| Width | 45 mm |
| Height | 93 mm |
| Depth | 76 mm |
| Rated operational power for AC-3, 400 V | 12.5 kW |
| Rated Continuous Current Iu | 25 A |
| Number of poles | 3 |
| Rated Operating Voltage | 690 V |
| Overload Trip Setting Range | 20 A |
| Power losses | 7.04 W |
| Protection Rating (IP) | IP20 |
| Main contact connection type | Screw Connection |
| Actuating element type | Knob |
| Tripping Method | Thermomagnetic |
| Rated Operating Power for AC-3, 230 V | 5.5 kW |
| Rated Short-Circuit Breaking Capacity Icu at 400 V, AC | 50 kA |
| Short-Circuit Trip Setting Range | 388 A |
| Device Design | Permanently Mounted Device |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,308 kg |
|---|---|
| Dimensions | 7,8 × 9,5 × 4,5 cm |
| Brand | Eaton |
| Length | 5 m |
| Rated Current | 32 A |










Reviews