Eaton HNB-C10/1N/003 RCBO C10 1P+N 30 mA Type AC 6 kA, 2 Modules

48,56 € (39,48 € netto)

Lowest price in the last 30 days: 48,56 €

Eaton RCBO 2P 10A 0.03A Type AC xPole Home HNB-C10/1N/003 195125 Key product features A robust connection, independent of supply voltage, combining the functions of a residual current device and an overcurrent circuit breaker in a single enclosure. Dual terminals (cage/busbar) at the top and bottom Contact position indicator, red/green colour Testing required every 6 months, not every month Tripping independent of mains voltage Type AC: sensitive to AC residual current 2 protections in 1 device Protection against electric shock and enhanced…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 195125 Category: EAN: 9010238060784 Brand:

Description

Eaton RCBO 2P 10A 0.03A Type AC xPole Home HNB-C10/1N/003 195125 Key product features A robust connection, independent of supply voltage, combining the functions of a residual current device and an overcurrent circuit breaker in a single enclosure. Dual terminals (cage/busbar) at the top and bottom Contact position indicator, red/green colour Testing required every 6 months, not every month Tripping independent of mains voltage Type AC: sensitive to AC residual current 2 protections in 1 device
Protection against electric shock and enhanced fire protection The residual current device integrated with the EATON overcurrent module protects the electrical installation against the effects of short circuits and overloads, allowing selective disconnection of only the faulty circuit. Protects against: FIRE | ELECTRIC SHOCK | DAMAGE TO ELECTRICAL EQUIPMENT Why choose Eaton RCBOs? Full safety The device effectively protects against the effects of electric shock and surges caused by direct and indirect lightning strikes. Replaceable varistor cartridges (with failure indication) Integrated surge protection provides protection against mains disturbances, and damage to the varistor cartridge is immediately visible thanks to the built-in indicator. Quick status verification An optical indicator shows the device status — a red signal indicates the need for replacement, while green confirms correct operation. Easy to install, convenient to use
Device status information at your fingertips Cage and busbar terminal Grey lever mechanically linked to the ON/OFF indicator Can be sealed in the ON and OFF position Red/green contact position indicator Simple DIN rail mounting Test button “T” (should be pressed every 6 months) Technical specification:

  • Tripping characteristic: C
  • Sensitivity: AC
  • Installation depth [mm]: 69.5
  • Number of poles: 2
  • Overvoltage category: 3
  • Width expressed as number of modules: 2
  • Rated short-circuit breaking capacity in accordance with IEC 60947-2 [kA]: 0
  • Protection Rating (IP): IP20
  • Rated Residual Current [A]: 0.03
  • Rated Current [A]: 10
  • Energy limitation class: 3
  • Pollution degree: 2
  • Rated short-circuit breaking capacity in accordance with EN 60898 [kA]: 6

Every day we take care of the safety of electrical circuits worldwide Combined circuit breakers
in electrical installations EATON RCBOs, also known as combined circuit breakers, combine the functions of two protective devices — overcurrent and residual current protection — in a single device. They protect the installation against overload and short circuit, as well as protecting users against electric shock and enhancing fire protection. In the event of a fault, they disconnect only the faulty circuit, minimising the risk of damage. A key advantage of the xPole Home series models is their compact design — a single device takes up less space in the distribution board than two separate circuit breakers, without losing any of the required functionality. A product series designed for modern projects The new Eaton xPole series circuit breakers are distinguished by excellent ergonomics, ensuring optimal operating temperature and improved electrical and mechanical durability. Optimal portfolio Easier selection Modern design Highest reliability and safety Easy installation High durability The circuit breaker is mounted on a DIN TH 35 mounting rail The device operates regardless of mounting position (vertical/horizontal)

  • Double cage/busbar terminals
  • Connecting busbar mounting on both sides top/bottom
  • After fitting the connecting busbar, a free cage terminal
  • Possibility of later fitting auxiliary contacts and trips

The next stage in the development of protective devices The Eaton xPole Home series represents a modern approach to electrical protection, combining advanced technologies with digital capabilities to provide an even higher level of safety and reliability. Overcurrent
circuit breakers HN

  • Protection against short circuits and overload
  • Basic fire protection

HNC
residual current circuit breakers

  • Earth fault protection
  • Basic fire protection
  • Protection against electric shock

HNB
combined circuit breakers

  • Earth fault protection
  • Protection against short circuits and overload
  • Enhanced fire protection

AFDD+ arc fault
detection device

  • Arc fault protection
  • Earth fault protection
  • Protection against short circuits and overload

Frequently asked questions RCD with overcurrent protection RCDs with overcurrent protection, also known as combined devices, combine the functions of an RCD and an MCB. In the EATON range, such devices can be found in the HNB and PKNM series. What is an RCD? A residual current device (RCD) is a protective element in an electrical installation whose task is to protect users against electric shock. When should an RCD be used? Its use is required in consumer installations, particularly where the PEN conductor has been split into separate PE and N conductors. Which type of RCD should be chosen? The choice depends on the type of equipment connected to the installation. For standard sockets and lighting, a type AC model is sufficient, while in the presence of electronic and power electronic equipment, type A or F RCDs are recommended. Is the installation of an RCD mandatory? Yes – in accordance with building law regulations, the use of RCDs in electrical installations is mandatory. Why does an RCD trip? The device reacts to leakage current, i.e. a situation where part of the current flows outside the protected circuit – this may indicate an electric shock or damaged insulation. In what situations does an RCD not protect against electric shock? Protection against direct contact is only effective for RCDs with a sensitivity of up to 30mA and circuits not exceeding 32A. At higher residual current values, such protection is not guaranteed. How does an RCD work? The device analyses the balance between the current flowing into and out of the circuit. In the event of a difference – indicating potential current leakage – it automatically switches off. How to correctly connect an RCD? Installation should be carried out in accordance with the manufacturer’s instructions and performed by a qualified electrician. Is there an RCD that protects against fire? Yes, in accordance with the EN HD 60364-4-42 standard, RCDs with a sensitivity of up to 300mA can serve a fire protection function. Example models include PF6-40/4/03 and PFIM-63/4/03-S/F.

Technical data – Residual current circuit breaker with overcurrent protection

Voltage TypeAC
Mounting Depth69.5 mm
Rated Current10 A
Rated Voltage230 V
Tripping CharacteristicC
Rated insulation voltage Ui500 V
Rated residual current0.03 A
SensitivityAC
Surge current resistance0.25 kA
Energy Limiting Class3
Overvoltage Category3
Pollution degree (N)2
Width in Number of Modules2
Frequency50 Hz
Protection Rating (IP)IP20
Number of Protected Poles1
Rated short-circuit breaking capacity in accordance with IEC 60947-20 kA
Cross-section of connectable single-wire conductor1 mm2
Cross-section of connectable multi-wire conductor1 mm2
Ambient operating temperature-25 °C
Number of Poles (Total)2
Rated impulse withstand voltage Uimp4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
Tripping characteristic typeInstantaneous
Rated short-circuit breaking capacity according to EN 610096 kA

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,212 kg
Dimensions8,5 × 7,5 × 3,5 cm
Brand

Eaton

Length

2 m

Rated Current

10 A

Reviews

There are no reviews yet.

Be the first to review “Eaton HNB-C10/1N/003 RCBO C10 1P+N 30 mA Type AC 6 kA, 2 Modules”

Your email address will not be published. Required fields are marked *