Legrand DX3 P312 C 20A/30mA/AC RCBO C20 1P+N 30 mA Type AC 6 kA, 2 Modules
62,51 € (50,82 € netto)
P 310 Residual Current Circuit Breakers with Overcurrent Protection, DX³ Series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal AC residual currents – Type A – detects sinusoidal AC residual currents and pulsating DC residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Two-pole 230 V~ Type AC – Characteristic C – Rated residual current: 30 mA – Rated current: 20 A – Width in modules 17.5 mm: 2 – Mounting on TH35 bracket – Can be connected using comb-type or pin-type busbars or…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
P 310 series DX³ residual current circuit breakers with overcurrent protection – Rated breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal alternating residual currents – Type A – detects sinusoidal alternating residual currents and pulsating direct currents – Compatible with the HX³ Optimal Energy Distribution System up to 125 A Double pole 230 V~ Type AC – Characteristic C – Rated residual current: 30 mA – Rated current: 20 A – Width in 17.5 mm modules: 2 – Mounting on TH35 bracket – Can be connected using comb or pin busbars – Can be fitted with auxiliary contacts, trip units and actuators from the DX³ series – Grey operating lever
Technical data – Residual current circuit breaker with overcurrent protection
| Voltage Type | AC |
| Mounting Depth | 44 mm |
| Rated Current | 20 A |
| Rated Voltage | 230 V |
| Tripping Characteristic | C |
| Rated residual current | 0.03 A |
| Sensitivity | AC |
| Surge current resistance | 0.25 kA |
| Energy Limiting Class | 3 |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 2 |
| Frequency | 50 Hz |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 1 |
| Rated short-circuit breaking capacity in accordance with IEC 60947-2 | 6 kA |
| Cross-section of connectable single-wire conductor | 0.75 mm2 |
| Cross-section of connectable multi-wire conductor | 0.75 mm2 |
| Number of Poles (Total) | 2 |
| Rated short-circuit breaking capacity Icn according to EN 61009-1 | 6 kA |
| Rated short-circuit breaking capacity according to EN 61009 | 6 kA |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,242 kg |
|---|---|
| Dimensions | 11 × 8,5 × 4 cm |
| Brand | Legrand |
| Length | 2 m |
| Rated Current | 125 A |



Reviews
There are no reviews yet.