Legrand DX3 P312 B 20A/30mA/AC RCBO B20 1P+N 30 mA Type AC 6 kA, 2 Modules

59,87 € (48,67 € netto)

Lowest price in the last 30 days: 59,87 €

P 310 Residual Current Circuit Breakers with Overcurrent Protection, DX³ Series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal AC residual currents – Type A – detects sinusoidal AC residual currents and pulsating DC residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Two-pole 230 V~ Type AC – Characteristic B – Rated residual current: 30 mA – Rated current: 20 A – Width in modules 17.5 mm: 2 – Mounting on TH35 bracket – Can be connected using comb-type or pin-type busbars or…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 410922 Category: EAN: 3414970351241 Brand:

Description

P 310 Residual Current Circuit Breakers with Overcurrent Protection, DX³ Series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal AC residual currents – Type A – detects sinusoidal AC residual currents and pulsating DC residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Two-pole 230 V~ Type AC – Characteristic B – Rated residual current: 30 mA – Rated current: 20 A – Width in modules 17.5 mm: 2 – Mounting on TH35 bracket – Can be connected using comb-type or pin-type busbars – Can be equipped with auxiliary contacts, trip units and drives from the DX³ series – Grey switching lever

Technical data – Residual current circuit breaker with overcurrent protection

Voltage TypeAC
Mounting Depth44 mm
Rated Current20 A
Rated Voltage230 V
Tripping CharacteristicB
Rated residual current0.03 A
SensitivityAC
Surge current resistance0.25 kA
Energy Limiting Class3
Pollution degree (N)2
Width in Number of Modules2
Frequency50 Hz
Protection Rating (IP)IP20
Number of Protected Poles1
Simultaneously disconnected N poleYes
Rated short-circuit breaking capacity in accordance with IEC 60947-26 kA
Cross-section of connectable single-wire conductor0.75 mm2
Cross-section of connectable multi-wire conductor0.75 mm2
With lockYes
Ambient operating temperature-25 °C
Number of Poles (Total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
Tripping characteristic typeInstantaneous
Rated short-circuit breaking capacity according to EN 610096 kA

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,24 kg
Dimensions10,5 × 8,5 × 4 cm
Brand

Legrand

Length

2 m

Rated Current

125 A

Reviews

There are no reviews yet.

Be the first to review “Legrand DX3 P312 B 20A/30mA/AC RCBO B20 1P+N 30 mA Type AC 6 kA, 2 Modules”