ETI Etitec C T2 275/20 1P Surge Arrester C 1-Pole 20/40 kA, 1.5 kV TN, 1 Module
16,03 € (13,03 € netto)
Reliable and Proven ETITEC C T2 Surge Arresters ETITEC C T2 surge arresters are designed for indoor use in sub-distribution boards as Type 2 arresters in accordance with EN 61643-11 and as Stage II in accordance with IEC 61643-11. They provide the second stage of protection against surges caused by indirect lightning strikes or switching surges. In the event of device failure, the internal thermal protection and fault indication are activated. In such a case, only the varistor cartridge needs to be replaced, without the need to replace the base, which is mounted on a…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Reliable and Proven ETITEC C T2 Surge Arresters ETITEC C T2 surge arresters are designed for indoor use in sub-distribution boards as Type 2 arresters in accordance with EN 61643-11 and as Stage II in accordance with IEC 61643-11. They provide the second stage of protection against surges caused by indirect lightning strikes or switching surges. In the event of device failure, the internal thermal protection and fault indication are activated. In such a case, only the varistor cartridge needs to be replaced, without the need to replace the base, which is mounted on a TH35 rail. The ETITEC C T2 255/20 G is a spark-gap arrester designed to protect against surges caused by indirect lightning strikes. It provides galvanic separation of the N conductor from the PE conductor in a TT network system. Technical Parameters
Individual identification number assigned by the manufacturer. 002440393
Product type as specified by the manufacturer. ETITEC C T2 275/20 1+0
Type T2 (II) arresters are a solution designed to protect against surges caused by indirect lightning strikes or switching surges. T2, II
Maximum voltage that can be continuously applied to the surge arrester without triggering it 275
Standard voltage for which the device is designed to operate. 230
TOV (Temporary OverVoltage) refers to transient overvoltages with elevated voltage levels. They occur, for example, due to loss of the neutral conductor, network asymmetry, or improper equipment operation. 442V/120min
safe disconnection
Discharge current with an 8/20 μs pulse that the device can withstand repeatedly during normal operation. 20
The highest impulse current (8/20μs) that the device can discharge once without damage. 40
Maximum voltage that appears at the arrester’s output during operation <1.5
An integrated system that disconnects the arrester from the installation in the event of overheating, preventing damage or fire. yes
Indication that additional protection is required when the main current exceeds 125A. 125A gG (max.)
Enclosure protection rating indicating resistance to ingress of solid objects and water. IP20
Indicates the type of internal component used in the surge arrester. In low-voltage technology, three main types are used: varistors (MOV), spark gaps (GDT), and combined (MOV+GDT). MOV
Surge arresters are available in 1, 2, 3 or 4 pole versions. 1
Width of the device expressed as a number of standard 18 millimetre modules. 1
The first digit in the designation 1+0, 2+0, etc. indicates the number of modules with varistors, the 2nd digit 1 indicates the N-PE pole with a spark gap. 1+0
Product photo
3D
Product advantages
- Each surge arrester includes thermal protection that disconnects it from the network if the current exceeds the maximum permissible value (Imax).
- Made with high-quality varistors.
- The designation includes key technical parameters and connection details, including maximum conductor cross-sections: 35 mm² (solid) and 25 mm² (stranded).
- Varistor condition indicator: red – damaged, green – functional.
- All surge arresters feature positioning elements that prevent improper installation of modules from a different surge arrester.
- The spark gap (GDT) is used as galvanic isolation between the N and PE conductors in TT network systems.
- Removable self-locking contacts for remote fault signalling (RC). Only for type ETIETC C T2 275/20…RC.
- Metal latch for quick mounting on a DIN rail.
- Special busbars IZ16/…/ETITEC for connecting single-pole devices.
Dimensional drawing
Internal circuits
ETIsON Curves
Programme functionalities:
- generating and plotting t/I characteristics of protective devices
- adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
- analysing selectivity between protective devices
- simulating load or short-circuit response of protective devices
- defining operating points and limit conditions from real applications
- preparing reports for design documentation
Check how simple it is!
Technical Data – Class C Surge Arrester
| Mounting Method | 35 mm DIN Rail |
| Number of conductors (excluding earth) | 1 |
| Size | 1 module |
| Poles | 1 |
| Maximum continuous operating voltage AC | 275 V |
| Rated discharge current – peak value (8/20) | 20 kA |
| Rated voltage AC | 230 V |
| Network system | Other |
| Operation indication on device | Optical |
| Protection Rating (IP) | IP20 |
| Max. conductor cross-section (solid/stranded) | 35 mm2 |
| Max. flexible conductor cross-section | 25 mm2 |
| Maximum discharge current (8/20) | 40 kA |
| Short-circuit withstand capacity (Isccr) | 25 kA |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,14 kg |
|---|---|
| Dimensions | 7,5 × 10,9 × 2,3 cm |
| Brand | ETI |
| Length | 1 m |
| Rated Current | 125 A |