ETI Etitec ML T123 300/12,5 4+0 Surge Arrester T1+T2+T3 B+C+D 4P 1.5 kV TNS, 4 Modules
120,67 € (98,11 € netto)
Reliable and proven ETITEC ML surge arresters ETITEC ML T123 surge arresters are a versatile solution providing Type 1, Type 2 and Type 3 (B, C, D) protection in electrical installations. Designed for mounting in the main distribution board, they protect against overvoltages caused by direct and indirect lightning strikes as well as switching overvoltages. Technical Parameters Catalogue Number: Individual identification number assigned by the manufacturer. 002440667 Product Code: Product type as specified by the manufacturer. ETITEC ML T123 300/12.5 4+0 Type according to…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Reliable and proven ETITEC ML surge arresters ETITEC ML T123 surge arresters are a versatile solution providing Type 1, Type 2 and Type 3 (B, C, D) protection in electrical installations. Designed for mounting in the main distribution board, they protect against overvoltages caused by direct and indirect lightning strikes as well as switching overvoltages. Technical Parameters
Individual identification number assigned by the manufacturer. 002440667
Product type as specified by the manufacturer. ETITEC ML T123 300/12.5 4+0
Type T1, T2 and T3 (I, II, III) arresters are a universal solution designed to protect against overvoltages caused by direct, indirect or switching lightning strikes. T1, T2, T3,
I, II, III
Maximum voltage that may be continuously applied to the surge arrester without triggering operation 300
Standard voltage for which the device is designed to operate. 230
TOV (Temporary OverVoltage) refers to transient overvoltages with elevated voltage levels. They occur, for example, due to loss of the neutral conductor, network asymmetry, or improper equipment operation. 442V/120min
safe disconnection
Surge current value with a specified pulse shape (10/350 μs) that the device can repeatedly discharge. 12.5
Discharge current with an 8/20 μs pulse that the device can withstand repeatedly during normal operation. 20
The highest impulse current (8/20μs) that the device can discharge once without damage. 40
Maximum voltage that appears at the arrester’s output during operation <1.5
Maximum current that may flow through the arrester after operation, before it is automatically disconnected from the network. Varistor-based arresters do not generate follow current. none
A measure of the energy dissipated by the device relative to its resistance – important for assessing durability. 39
An integrated system that disconnects the arrester from the installation in the event of overheating, preventing damage or fire. yes
Indicates that additional protection is required when the main protection current exceeds 160 A. 160A gG (max.)
Enclosure protection rating indicating resistance to ingress of solid objects and water. IP20
Indicates the type of internal component used in the surge arrester. In low-voltage technology, three main types are used: varistors (MOV), spark gaps (GDT), and combined (MOV+GDT). MOV
Surge arresters are available in 1, 2, 3 or 4-pole versions. 4
Width of the device expressed in the number of standard 18 mm modules. 4
The first digit in the designation 1+0, 2+0, etc. indicates the number of modules with varistors, the second digit 1 indicates an N-PE pole with a spark gap. 4+0
Product photo
3D
Product advantages
- Each surge arrester includes thermal protection that disconnects it from the network if the current exceeds the maximum permissible value (Imax).
- Made with high-quality varistors.
- The designation includes key technical parameters and connection details, including maximum conductor cross-sections: 35 mm² (solid) and 25 mm² (stranded).
- Varistor condition indicator: red – damaged, green – functional.
- All surge arresters feature positioning elements that prevent improper installation of modules from a different surge arrester.
- All surge arresters allow quick module replacement. A locking latch prevents accidental removal and increases vibration resistance.
- A double earthing terminal allows for an additional earth conductor connection.
- Quick-mount latch for DIN rail installation.
- Removable self-locking contacts for remote fault signalling (RC). Only for type ETIETC ML T123 300/12.5…RC
- When using multiple single-pole surge arresters, it is possible to simultaneously connect busbars and conductors from the top and bottom.
Dimensional drawing
Internal circuits ETITEC ML T123 300/12.5 RC
ETIsON Curves
Programme functionalities:
- generating and plotting t/I characteristics of protective devices
- adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
- analysing selectivity between protective devices
- simulating load or short-circuit response of protective devices
- defining operating points and limit conditions from real applications
- preparing reports for design documentation
Check how simple it is!
Technical data – Class B+C surge arrester
| Mounting Method | 35 mm DIN Rail |
| Number of poles | 4 |
| Size | 4 modules |
| Maximum continuous operating voltage AC | 300 V |
| Rated voltage AC | 230 V |
| Rated voltage DC | 0 V |
| Network system | TN network |
| Protection class | Type 1+2 |
| Operation indication on device | Optical |
| Maximum continuous operating voltage DC | 0 V |
| Protection Rating (IP) | IP20 |
| Max. conductor cross-section (solid/stranded) | 35 mm2 |
| Max. flexible conductor cross-section | 25 mm2 |
| Specific energy (W/R) | 39 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,564 kg |
|---|---|
| Dimensions | 8 × 11 × 10 cm |
| Brand | ETI |







Reviews
There are no reviews yet.