F&F CKF-BR Phase Sequence and Failure Sensor 10A 1-Pole 2 Modules, 3X400V/230V+N AC, Adjustable Asymmetry Threshold
21,58 € (17,54 € netto)
CKF-BR Phase Sequence and Failure Sensor – Product Template – F&F home and industrial automation CKF-BR Phase Sequence and Failure Sensor CKF-BR Phase Sequence and Failure Sensor CKF-BR is a phase control relay designed to protect electric motors supplied from a three-phase 3 × 400 + N network. The device monitors phase presence, voltage asymmetry and correct phase sequence, thereby reducing the risk of motor operation under conditions that could cause damage or incorrect rotation direction. It is a practical solution for industrial automation switchboards…
Out of stock
Description
CKF-BR Phase Sequence and Loss Sensor – Product Template – F&F Home and Industrial Automation
CKF-BR
CKF-BR Phase Sequence and Loss Sensor
CKF-BR Phase Sequence and Loss Sensor
CKF-BR is a phase control relay designed to protect electric motors supplied from a three-phase 3 × 400 + N network. The device monitors phase presence, voltage asymmetry and correct phase sequence, thereby reducing the risk of motor operation under conditions that could cause damage or incorrect rotation direction. It is a practical solution for industrial automation switchboards, building technical installations and drive control systems, where reliable protection of three-phase motors is essential. The sensor reacts to voltage loss on any phase and to exceeding the set voltage asymmetry threshold within the range of 40÷80 V. Tripping occurs with a 4 s delay, which helps avoid unnecessary disconnections during brief voltage dips. Automatic reconnection occurs once correct supply parameters return and the threshold is exceeded by the hysteresis value of 5 V. CKF-BR is suitable wherever phase failure sensors, supply asymmetry protection, phase sequence control and phase voltage sensors are required to monitor the operation of three-phase equipment. The 1 × NO/NC relay output with contact separation allows integration with control systems, contactors and protection circuits. Mounting on a TH-35 DIN rail, screw terminals and a compact width of 2 modules make installation in standard switchboards easier.
Why choose CKF-BR?
Power supply 3 × 400 V + N
Phase failure and asymmetry monitoring
Supply phase sequence control
Adjustable threshold 40÷80 V
Switch-off delay 4 s
NO/NC relay output 10 A
Two power supply indicator LEDs
TH-35 rail mounting
Power consumption 0.8 W
Phase failure protection
CKF-BR switches off the protected circuit when voltage is lost on at least one phase. This helps reduce the risk of overload and damage to a three-phase motor operating in an industrial or technical installation.
Adjustable voltage asymmetry
The asymmetry trip threshold can be set within the range of 40÷80 V, adapting the device’s response to the installation requirements. A 5 V hysteresis supports stable return to operation after voltage normalisation.
Incorrect phase sequence lockout
The device detects incorrect phase sequence and prevents the motor from starting when there is a risk of reverse rotation direction. This is particularly important for drives, pumps, fans and machines requiring the correct direction of operation.
Three-phase monitoring
Monitors phases in 3 × 400 V + N installations.
Automatic operation
Automatically returns to switched-on state after parameters normalise.
For switchboards
Compact width of 35 mm facilitates modular installation.
CKF-BR – device visualisation
Discover other benefits of CKF-BR
Modular enclosure
The device has a compact housing with a width of 2 modules, designed for switchboard mounting.
DIN rail mounting
The housing design allows the sensor to be mounted on a standard TH-35 DIN rail in a control cabinet.
Screw terminals
The housing features screw terminals for connecting cables, suitable for cross-sections up to 4.0 mm².
LED signal indicators
The front of the device is equipped with two LEDs intended for monitoring and visual indication of the power supply status.
Trip threshold adjustment
The device panel features adjustment of the voltage asymmetry threshold within the range specified for the CKF-BR model.
Additional materials
See also: CKF-318, CZF-BT Phase Control Relays
See also: Video Tutorial Practical Electrician – CKF 318 – phase sequence sensor
HEAT PUMP PROTECTION
GUIDE
How to check the phase sequence in a three-phase low-voltage electrical installation
GUIDE
Diagrams
Dimensions Connection Diagram
Technical Parameters
With detachable terminals No External power supply required Yes Phase sequence control Yes Phase failure detection Yes Undervoltage control function Yes Overvoltage control function No Phase asymmetry control Yes Minimum adjustable power failure trip delay 1.5 s Number of NO contacts 0 Type of electrical connection Screw connection Supply voltage for AC 50 Hz 150-280 V Minimum adjustable power-up trip delay 3.5 s Maximum allowed power-up trip delay 3.5 s Maximum allowed power failure trip delay 1.5 s Number of NC contacts 0 Number of CO contacts 1 Operating voltage for AC 50 Hz 150-280 V Rated switching current 16 A Supply voltage type AC Supply voltage type AC Depth 0 mm Height 0 mm Width 0 mm
Discover our other solutions!
| CKF-317 CKF-317 With adjustable voltage asymmetry trip threshold. Contact 1 x NO/NC. Phase sequence and loss sensor CKF-317 is designed to protect electric motors supplied from a three-phase network in situations that could damage the motor, such as voltage loss in at least one phase or voltage asymmetry between phases. It also protects the motor’s direction of rotation in the event of phase reversal upstream of the sensor. | CKF-317-TRMS CKF-317-TRMS With an adjustable voltage asymmetry trip threshold. 1 x NO/NC contact. The phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The sensor will trip when voltage is lost in at least one phase or when voltage asymmetry occurs between phases (risk of motor damage). The CKF-317-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-319-TRMS CKF-319-TRMS CKF-319 TrueRMS Phase Sequence and Phase Failure Sensor For protecting electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-319-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. | CKF-B CKF-B With fixed voltage asymmetry trip threshold. 1 × NO contact. The phase sequence and failure sensor is designed to protect electric motors supplied from a three-phase network when voltage is lost on at least one phase or voltage asymmetry occurs between phases, risking motor damage. The phase sequence and failure sensor also protects the motor’s rotation direction in the event of phase changes upstream of the sensor. | CKF-BR-TRMS CKF-BR-TRMS With an adjustable voltage asymmetry trip threshold. 1 x NO/NC contact. The CKF-BR TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor. The CKF-BR-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction | CKF-BT CKF-BT CKF-BT phase sequence and loss sensor with adjustable trip time. Contact 1NO/NC. The phase sequence and loss sensor is designed to protect electric motors supplied from a three-phase network against damage in the event of voltage loss in at least one phase or voltage asymmetry between phases. It also protects the motor’s direction of rotation in the event of phase reversal upstream of the sensor. | CKF-B-TRMS CKF-B-TRMS With a fixed voltage asymmetry trip threshold. 1 x NO contact. The CKF-B TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply in cases of voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor, as well as to protect the direction of motor rotation in the event of phase changes upstream of the sensor. | CKF-BT-TRMS CKF-BT-TRMS With adjustable trip delay time. 1NO/NC contact. The CKF-BT-TrueRMS phase sequence and phase failure sensor is designed to protect electric motors powered from a three-phase mains supply. The phase sequence and phase failure sensor will trip in the event of voltage loss in at least one phase or when voltage asymmetry occurs between phases. In other words, when there is a risk of motor damage. The CKF-BT-TrueRMS also monitors the supply phase sequence, preventing the motor from rotating in the wrong direction. |
|---|
Files to download
CKF-BR-declaration-pref-origin-status-1.pdf CKF-BR-declaration-RoHS-pl-1.pdf ckf-br-instrukcja-obslugi.pdf ckf-br-true-rms-instrukcja-obslugi.pdf ckf-br-schemat-cad-dxf.dxf ckf-czf-cp-deklaracja-ce-2025.pdf
About F&F
F&F is a Polish manufacturer of home and industrial automation with many years of experience. For years we have been delivering innovative, reliable and easy-to-use solutions that enhance comfort and safety in homes and production facilities. We design and manufacture our devices entirely in Poland, placing particular emphasis on quality, modern technologies and technical support for our customers.
Polish manufacturer of home and industrial automation
Technical Data – Phase Control Relay
| Width | 0 mm |
| Height | 0 mm |
| Depth | 0 mm |
| Voltage Measurement Range | 190 V |
| Supply voltage type | AC |
| Type of Electrical Connection | Screw Connection |
| Supply Voltage Type | AC |
| Rated Making Current | 16 A |
| Supply voltage for AC 50 Hz | 150 V |
| Maximum Allowable Delay on Power-Up | 3.5 s |
| Minimum Adjustable Delay on Power-Up | 3.5 s |
| Maximum Allowable Delay on Power Failure | 1.5 s |
| Minimum Adjustable Delay on Power Failure | 1.5 s |
| Operating voltage for AC 50 Hz | 150 V |
| Number of NC Contacts | 0 |
| Number of NO Contacts | 0 |
| Number of Changeover Contacts | 1 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,098 kg |
|---|---|
| Dimensions | 9,5 × 9,5 × 4 cm |
| Brand | F&F |
| Length | 2 m |
| Rated Current | 10 A |
| Number of Phases | Single Phase |











Reviews