F&F CZF-310 Phase Failure and Asymmetry Sensor 10A 1-Pole 1 Module, 3X400/230V+N AC
19,98 € (16,24 € netto)
With fixed voltage asymmetry trip threshold. Contact 1 x NO/NC. The phase loss sensor is designed to protect an electric motor supplied from a three-phase network in situations involving voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor. Supply voltage 3 × 400 V + N Compatible with generator sets NO Phase loss / asymmetry control YES Phase sequence control NO Contactor contact monitoring NO Actuating element relay Maximum load current 10 A Contact configuration 1 × NO/NC Contact…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
With fixed voltage asymmetry trip threshold. Contact 1 x NO/NC. The phase loss sensor is designed to protect an electric motor supplied from a three-phase network in situations involving voltage loss in at least one phase or voltage asymmetry between phases, which could damage the motor. Supply voltage 3 × 400 V + N Compatible with generator sets NO Phase loss / asymmetry control YES Phase sequence control NO Contactor contact monitoring NO Actuating element relay Maximum load current 10 A Contact configuration 1 × NO/NC Contact isolation YES Voltage asymmetry trip threshold 55 V Voltage hysteresis 5 V Shutdown delay 4 s Power supply monitoring 3 × green LED Connection screw terminals 2.5 mm² Tightening torque 0.4 Nm Power consumption 0.56 W Operating temperature -25÷40°C Dimensions 1 module (18 mm) DIN rail mounting 35 mm Protection Rating (IP) IP20
Technical Data – Phase Control Relay
| Width | 0 mm |
| Height | 0 mm |
| Depth | 0 mm |
| Voltage Measurement Range | 140 V |
| Supply voltage type | AC |
| Type of Electrical Connection | Screw Connection |
| Supply Voltage Type | AC |
| Rated Making Current | 10 A |
| Supply voltage for AC 50 Hz | 150 V |
| Maximum Allowable Delay on Power-Up | 4 s |
| Minimum Adjustable Delay on Power-Up | 4 s |
| Maximum Allowable Delay on Power Failure | 1 s |
| Minimum Adjustable Delay on Power Failure | 1 s |
| Operating voltage for AC 50 Hz | 150 V |
| Number of NC Contacts | 0 |
| Number of NO Contacts | 0 |
| Number of Changeover Contacts | 1 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,074 kg |
|---|---|
| Dimensions | 9,5 × 9,5 × 2 cm |
| Brand | F&F |
| Length | 1 m |
| Rated Current | 10 A |
| Number of Phases | Single Phase |