Eaton xPole Home HN-B40/1 Miniature Circuit Breaker B40 1-Pole 6 kA, 1 Module

7,05 € (5,73 € netto)

Lowest price in the last 30 days: 7,05 €

Miniature Circuit Breaker 1P B 40A 6 xPole Home HN-B40/1 194825 Key product features Model 194825 features time-current characteristic B (so-called fast) and a rated current of 40A. Breaking capacity is 6kA. Operates at 230VAC and 48VDC Double terminals on both sides of the device — cage-clamp for cable and rail-mount for busbars Meets insulation coordination requirements, contact gap 3>4 mm to ensure safe insulation Mounting on DIN rail TH 35 Supply from either side of the device A range of products ensuring protection and safety in modern installations Miniature circuit breakers…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 194825 Category: EAN: 9010238063099 Brand:

Description

Miniature Circuit Breaker1P B 40A 6 xPole Home HN-B40/1 194825Key product featuresModel 194825 features time-current characteristic B (so-called fast) and a rated current of 40A. Breaking capacity is 6kA.Operates at 230VAC and 48VDCDouble terminals on both sides of the device — cage-clamp for cable and rail-mount for busbarsMeets insulation coordination requirements, contact gap 3>4 mm to ensure safe insulationMounting on DIN rail TH 35Supply from either side of the deviceA range of products ensuring protection and safety in modern installationsEATON miniature circuit breakers protect electrical installations against the effects of overloads and short circuits. They operate automatically – in the event of excessive current or a short circuit, they instantly interrupt the circuit, preventing damage to the installation and increasing user safety.SOCKET CIRCUITS | LIGHTING CIRCUITS | TV AND HOUSEHOLD APPLIANCESWhy choose an Eaton miniature circuit breaker?Simplified designModern and minimalist design makes the device easy to operate and blends well with its surroundings.Resistance and durability in harsh environmentsThe breakers perform well both indoors and outdoors, thanks to high resistance to external factors.Compatibility with other devicesThe modular design allows the device to be easily equipped with add-on elements that extend its functions – such as auxiliary contacts, trip units or locks.easy to install, convenient to use
Device status information at a glanceCage-clamp and rail terminalGrey lever mechanically linked to the ON/OFF indicatorCan be sealed in the ON and OFF positionRed/green contact position indicatorSimple mounting on DIN railTechnical specification:

  • Model: HN-B40/1
  • Protection Rating (IP): IP20
  • Mounting depth [mm]: 71
  • Rated short-circuit breaking capacity in accordance with EN 60898 [kA]: 6
  • Energy limitation class: 3
  • Voltage type: AC
  • Tripping characteristic: B
  • Number of Poles: 1
  • Rated Current [A]: 40
  • Width expressed in number of modules: 1

A miniature circuit breaker designed to protect electrical installations in low-voltage systemsAn overcurrent protection device (commonly known as a “fuse breaker”) is designed to protect the electrical installation against overload. Overload occurs when a circuit carries an excessively high current, which can happen when too many devices are connected to the same circuit. EATON miniature circuit breakers also provide protection against short circuits, which can occur when two conductors come into contact with each other, causing a high current flow and risk of damage to electrical devices. Type B circuit breakers are commonly used to protect sockets and lighting circuits, making them the most common protective device in electrical installations.Watch the video about miniature circuit breakers and discover the full range of overload protection devices from xPole HomeA range of products designed
for modern projectsThe new xPole Home product line, including HN miniature circuit breakers, HNB combined circuit breakers, and HNC residual current circuit breakers, has been designed to ensure maximum safety and efficiency in the design process. It is characterised by simple design, reliability, and full compliance with applicable standards. Devices from the xPole Home series are readily available and easy to install. HN miniature circuit breakers from this series work excellently in residential, commercial, and industrial installations, protecting both users and equipment.Advantages of the xPole Home seriesThe new Eaton xPole series circuit breakers stand out with excellent ergonomics, ensuring optimal operating temperature and improved electrical and mechanical durability.Optimal portfolioeasier selectionModern designHighest reliability and safetyeasy installationHigh durabilityThe next stage in the development of protective devicesEATON AFDD+ is not only an improved version of previous models, but also the next step in the development of protective devices, utilising the latest technologies and digital innovations.Protection against short circuits and overloadsEarth fault protectionArc fault protectionFire protectionEarth fault protectionHN
miniature circuit breakers+–basic-HNC
residual current circuit breakers-+-basic+HNB
combined circuit breaker++-enhanced+AFDD device++++extended+Frequently asked questionsStructure and operating principle of a miniature circuit breakerA miniature circuit breaker consists of two main components: a thermal bimetallic trip (overload) and an electromagnetic trip (short-circuit). It works to protect the electrical installation against overloads and short circuits, preventing fires or electric shock. In the event of prolonged overload, the thermal bimetallic trip heats up and causes the circuit to switch off. In the event of a short circuit, the electromagnetic trip reacts quickly and extinguishes the electric arc, preventing damage to devices.Which breaker: B or C?Miniature circuit breakers come with various tripping characteristics, such as Z, B, C, D, K, S. The B characteristic is used in socket circuits and traditional lighting (resistive loads), while the C characteristic is used for protecting devices with capacitive characteristics, such as LED lighting, induction hobs, gate actuators, or home automation.When does a miniature circuit breaker trip?A miniature circuit breaker trips when the current flowing through the circuit exceeds its rated value. For example, for a 10A breaker, this would be a current exceeding 11.3A. The second case is a short circuit, i.e. the flow of a very high current, which causes the breaker to trip immediately.How to connect a miniature circuit breakerEATON miniature circuit breakers are equipped with double terminals, allowing connection of cables (cage clamp terminals) or busbars (rail-type terminals). The connection should be made by a qualified electrician.Can a miniature circuit breaker fail?Yes, miniature circuit breakers are designed with a specific short-circuit withstand capacity. For example, the HN series is designed to break short circuits up to 6000A, in accordance with EN 60898-1. A higher short-circuit current may damage the device.Which breaker for an induction hob?Induction hobs typically require three-phase, three-pole circuit breakers. Depending on the power of the hob, an HN-B16/3 or HN-B20/3 breaker is used.Which breaker for lighting?To protect traditional incandescent or halogen lighting, an HN-B10/1 breaker (single-phase, 10A, B characteristic) is used. For LED lighting, especially in multi-family buildings in common areas, a breaker with a C characteristic is a better choice due to the high inrush currents of LED fittings.DC circuit breakerEATON miniature circuit breakers can operate with DC voltage up to 48V DC. For higher voltages, the PL7 DC or FAZ DC series are suitable, supporting voltages up to 250V DC or 500V DC in series connection.Which side should the circuit breaker be supplied from?EATON miniature circuit breakers are universal and can be supplied from either the bottom or the top. Regardless of the connection direction, the device will provide effective installation protection.Miniature circuit breakers vs residual current devicesMiniature circuit breakers protect against the effects of short circuits and overloads, and can also prevent fires and electric shocks. Residual current devices protect against electric shock as well as fires. In Polish electrical installations, both of these devices are mandatory and work in synergy, complementing each other.

Technical Data – Miniature Circuit Breaker

Voltage TypeAC
Mounting Depth44 mm
Rated Current40 A
Rated Voltage230 V
Frequency Range50 Hz
Tripping CharacteristicB
Rated insulation voltage Ui440 V
Energy Limiting Class3
Overvoltage Category3
Pollution degree (N)3
Width in Number of Modules1
Power losses3.4 W
Protection Rating (IP)IP20
Number of Protected Poles1
Cross-section of connectable single-wire conductor1 mm2
Cross-section of connectable multi-wire conductor1 mm2
Ambient operating temperature-25 °C
Number of Poles (Total)1
Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V6 kA
Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V6 kA
Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V0 kA
Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V0 kA
Rated impulse withstand voltage Uimp4 kV

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,137 kg
Dimensions7,5 × 1,7 × 8 cm
Brand

Eaton

Length

1 m

Rated Current

10 A

Reviews

There are no reviews yet.

Be the first to review “Eaton xPole Home HN-B40/1 Miniature Circuit Breaker B40 1-Pole 6 kA, 1 Module”

Your email address will not be published. Required fields are marked *