Eaton SPDT3-335-1+NPE Surge Protective Device Type 3 D 2-Pole 2.5/10 kA 1.6 kV, 2 Modules
77,79 € (63,24 € netto)
Eaton Surge Protective Device D Type 3 2P 2.5kA 1kV SPDT3-335-1+NPE 170487 Main product features EATON surge protective devices are universal solutions that protect electrical installations against the effects of surges. The devices effectively reduce both direct discharges and indirect surges. Compliance with IEC 61643-1+A1 for class I+II protection Type T3 surge protective device in accordance with EN 61643-11 Versions with an operating voltage of AC 280 – 335 AC Replaceable cartridges Optical indicator showing cartridge damage Watch the video about surge protective devices and discover the…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton Surge Protective Device D Type 3 2P 2.5kA 1kV SPDT3-335-1+NPE 170487 Main product features EATON surge protective devices are universal solutions that protect electrical installations against the effects of surges. The devices effectively reduce both direct discharges and indirect surges. Compliance with IEC 61643-1+A1 for class I+II protection Type T3 surge protective device in accordance with EN 61643-11 Versions with an operating voltage of AC 280 – 335 AC Replaceable cartridges Optical indicator showing cartridge damage Watch the video about surge protective devices and discover the full range of low-voltage protection devices A mandatory component of your home’s electrical installation
Protection against electrical surges A surge protective device is installed to protect electrical installations against the effects of indirect lightning strikes and surges resulting from switching operations. It constitutes an additional layer of protection, usually installed in sub-distribution boards — downstream of the main type 1 arresters. BRANCH DISTRIBUTION BOARDS | FLOOR DISTRIBUTION BOARDS | DISTRIBUTION PANELS Why choose an Eaton surge protective device? Increased safety The device effectively protects the installation against both the direct and indirect effects of lightning strikes. Replaceable varistor cartridges and their indication It provides excellent protection against surges resulting from indirect lightning strikes and switching operations in the network, and thanks to replaceable varistor cartridges, a quick response is possible in the event of wear. Intuitive monitoring of the arrester’s condition The technical condition of the device can be easily assessed thanks to the optical indicator — red indicates that the cartridge needs to be replaced, green indicates correct operation. Easy to install, convenient to use
Device status information at your fingertips Optical cartridge-blown indicator Lift and rail terminals Information on key parameters Simple DIN rail mounting Technical specification:
- Type: SPDT3-335-1+NPE
- Arrester type: T3
- Rated AC voltage [V]: 260
- Protection level L-N [kV]: 1
- Number of poles: 2
- Nominal discharge current (8/20) (L-N) [kA]: 2.5
- Operation signalling on device: Optical
- Protection level Up [kV]: 1
- Rated current [A]: 16
- Protection level L-PE/N-PE [kV]: 1
- Maximum continuous operating AC voltage [V]: 260
- Nominal discharge current (8/20) (L+N-PE) [kA]: 2.5
Main factors
contributing to surges Surges can result from violent weather phenomena, such as thunderstorms, or unexpected faults in the electrical network. This type of voltage spike poses a threat to the entire electrical installation and can damage connected devices. For this reason, installations in residential, commercial and industrial buildings should be equipped with both a lightning protection system and surge protection devices. Effective protection against lightning strikes and switching surges plays a key role in ensuring the safety of a building, and also reduces the risk of fire or electric shock. Surge Protective Devices
in electrical installations Surge protective devices protect electrical equipment against the effects of surges and atmospheric discharges, including lightning strikes. When voltage rises – for example as a result of a lightning strike – the surge arrester reacts instantly, reducing the voltage to a level that is safe for the receivers in the installation. In Polish electrical installations, the installation of this type of protection is required by regulations. EATON surge protective devices provide a high level of protection thanks to the use of varistors, which are characterised by an extremely fast response time and a high energy absorption capacity. An additional advantage is the optical fault indicator, which informs the user when the device needs to be replaced due to damage. Surge protective devices should be installed in: 1 2 3 4 5 buildings with an external lightning protection system buildings with an external overhead line and a lightning protection system a protected facility where the internal steel structure is used as the lightning protection system buildings supplied by cable line, where the distance between the building and the transformer station is small (possibility of high short-circuit currents occurring) facilities without a lightning protection system in close proximity to tall structures, where the earthing systems of the structures are connected Explore the Eaton product range and choose the right surge arrester for you Test class I/II
for photovoltaic
installations
[T1/2 PV] Test class II
for photovoltaic
installations
[T2 PV] Test class I/II
[T1/2] Test class II
[T2] Test class III
[T3] Standalone DIN rail mounting
Connect to your existing installation To ensure correct operation, the sets should be installed — viewed from the supply side — before measuring devices and residual current devices. This solution minimises the risk of their incorrect operation when a surge occurs and surge current flows after the arresters are activated. Global demand for electricity is constantly growing Faced with growing global demand for energy, EATON offers modern energy management solutions that help save resources, increase the reliability of power supply, and improve safety and quality of life. The company operates in more than 175 countries, delivering environmentally friendly technologies that support sustainable development. Frequently asked questions What is a surge protective device? A surge protective device is an electrical protection designed to protect the electrical installation and equipment against the effects of atmospheric discharges and switching surges. Is installing a surge arrester mandatory? Yes, in new buildings its presence has been required by technical regulations since 2002. Which model for a home? Class 1+2 (formerly B+C) surge arresters are most commonly used, as they provide comprehensive protection against the effects of both direct and indirect lightning strikes. When should it be used? A surge protective device should protect every electrical installation commissioned after April 2002. A lightning strike is a phenomenon that anyone can experience, and even older buildings are just as exposed to the effects of lightning as newly built ones. How to connect it correctly? Surge protective devices have marked terminals — supply cables are connected at the top of the device, and the protective conductor at the bottom. In addition, the cables must be tightened with a torque wrench at the appropriate torque so that they do not come loose from the terminals while discharging surge current. How to protect it? Since the surge arrester does not protect against short circuits, it should be protected with a fuse link in accordance with the manufacturer’s recommendations. How to install it? It should be mounted on a TH rail in the distribution board, maintaining the correct cable cross-sections and lengths. The terminals are marked – the top ones for the supply, the bottom ones for the protective conductor and earthing. How to check its condition? EATON surge protective devices have an optical indicator showing when the cartridge has blown. Green indicates a functional cartridge, while red indicates that the cartridge is damaged and needs to be replaced. In the case of 3+1 arresters with a summation spark gap, the spark gap cartridge is blue, turning red when damaged. In addition, a visual inspection of the device should always be carried out. Which surge protective device for an apartment block? In apartment blocks commissioned after 2002, surge protective devices will be present in the main distribution boards. However, as these are located at a considerable distance from the protected flats, it is recommended to provide additional protection for equipment within flats — with a type 2 (formerly C) SPCT2 arrester in the apartment distribution board, and with type 3 (formerly D) SPDT3 series arresters for sensitive devices such as fridges, smart TVs or routers. In older buildings, instead of a class II arrester in the apartment distribution board, it is recommended to install a class I+II (formerly B+C) arrester. What type of surge arrester for a PV installation? For roof-mounted panels without a lightning protection system, a class II model (SPPVRT2) is sufficient. For systems with lightning protection or free-standing installations, a type 1+2 model (SPPVRET12) is recommended.
Technical Data – Class C Surge Arrester
| Mounting Method | 35 mm DIN Rail |
| With contact for remote signalling | No |
| Number of conductors (excluding earth) | 1 |
| Number of poles | 2 |
| Size | 2 modules |
| Protection level | 1.6 kV |
| Maximum continuous operating voltage AC | 335 V |
| Rated discharge current – peak value (8/20) | 2.5 kA |
| Rated voltage AC | 335 V |
| Rated voltage DC | 0 V |
| Type 2 | No |
| Protection level L-N | 0 kV |
| Operation indication on device | Optical |
| Maximum continuous operating voltage DC | 0 V |
| Protection Rating (IP) | IP20 |
| Maximum voltage of the photovoltaic installation | 0 V |
| Protection level N-PE | 0 kV |
| Integrated backup fuse protection | No |
| Max. conductor cross-section (solid/stranded) | 25 mm2 |
| Max. flexible conductor cross-section | 0 mm2 |
| DC network configuration | No |
| IT network configuration | No |
| TN network configuration | No |
| TN-C network configuration | No |
| TN-S network configuration | No |
| TT network configuration | No |
| Other network system | Yes |
| TN-C-S network configuration | No |
| Maximum discharge current (8/20) | 10 kA |
| Short-circuit withstand capacity (Isccr) | 0 kA |
| Maximum Overcurrent Protection, Parallel Connection (Fuse) | 0 A |
| Max. overcurrent protection, series connection (fuse) | 125 A |
| Integrated short-circuit protection | No |
| Integrated short-circuit protection, selective with gG fuse | 0 A |
| No leakage current | No |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,198 kg |
|---|---|
| Dimensions | 6,8 × 3,5 × 8 cm |
| Brand | Eaton |
| Length | 2 m |




Reviews
There are no reviews yet.