Eaton DILM9-01-EA Power Contactor 9A 3NO+1NC 4 kW 230 V AC, Screw Terminals
27,21 € (22,12 € netto)
Eaton 0.9 190031 4015081880270 24_10_2023 Power Contactor DILM9‑01‑EA(230V50HZ,240V60HZ) 9A 3P 230V AC 0NO 1NC 190031 Key Product Features The device is available in a screw-connection version. It is equipped with one integrated auxiliary contact of NO or NC type, while models with Push-in technology feature two auxiliary contacts – NO and NC. Contactors powered by direct current (DC) have a built-in internal protection circuit. In variants with current ratings from 17A upwards, an electronic coil is used, which stands out for its low energy consumption. They can be expanded with front…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton 0.9 190031 4015081880270 24_10_2023 Power Contactor DILM9‑01‑EA(230V50HZ,240V60HZ)
9A 3P 230V AC 0NO 1NC 190031 Key Product Features The device is available in a screw-connection version. It is equipped with one integrated auxiliary contact of NO or NC type, while models with Push-in technology feature two auxiliary contacts – NO and NC. Contactors powered by direct current (DC) have a built-in internal protection circuit. In variants with current ratings from 17A upwards, an electronic coil is used, which stands out for its low energy consumption. They can be expanded with front auxiliary contacts and side-mounted auxiliary contactors. The use of a special mechanical-electrical adapter allows for quick and easy connection of the contactor with PKZ series motor-protective circuit breakers. Designed for a wide current range Operating range from 7A to 2600A. Thanks to their compact design, electronic drives, and high durability, DILM contactors are a robust and reliable solution for machines and systems in various industrial applications. Power contactors from the DILM series ‑ where are they used? Motor control DILM contactors are designed to handle motors, i.e. inductive loads, ensuring their effective switching on and off. Versatile use in industry They perform well in various industrial sectors – from machine building, through production lines, to maintenance. Ideal for installation in switchboards and control panels of machines and equipment. Control of resistive loads and lighting Thanks to their solid technical parameters, DILM contactors are also suitable for managing resistive loads (e.g. heaters) and various types of lighting systems. What distinguishes the DILM9 power contactor? Utilisation category AC‑1 and AC‑3 Suitable for voltage up to 1,000 V Electronic coil as standard from 17A for DC and from 115A for AC Low coil holding and pick-up power Compact size Auxiliary contacts: two NO, two NC Technical specification: Number of main NO contacts: 3 Number of auxiliary NC contacts: 1 Control voltage type: AC Main circuit connection type: Screw connection Product series: DILM Modular version: No Rated operating current Ie for AC‑1, 400 V [A]: 14 Rated operating power at AC‑3, 400 V [kW]: 4 Rated operating current Ie at AC‑3, 400 V [A]: 9 Mounting method of DILM contactors DILM contactors are equipped with double, independent terminal cages, allowing for secure and safe connection of two cables with different cross-sections. This solution minimises the risk of a cable coming loose, protecting the installation against short circuit or electric shock. Contactors with high technical parameters Can be used for disconnecting local networks, operating drives controlled by frequency converters, conducting inductive and capacitive currents without switching them, and galvanic isolation of system parts when inverters/frequency converters are used. Online motor starter configurator A practical tool enabling quick selection of contactors, motor-protective circuit breakers, and overload relays for direct-on-line, reversing, and star-delta starting systems. Discover the advantages of DILM contactors Built with 3 main poles for three phases. One built-in auxiliary contact of NO (normally open) or NC (normally closed) type. Separate terminals for coil control (A1‑A2). Operating voltage Main current poles Rated operating power AC‑3 / 400 V [kW] Number of built-in auxiliary contacts Control coil Built-in suppression circuit DILM7 Power Contactors Up to 690VAC 3NO 3 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM9 Power Contactors Up to 690VAC 3NO 4 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM12 Power Contactors Up to 690VAC 3NO 5.5 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM15 Power Contactors Up to 690VAC 3NO 7.5 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM17 Power Contactors Up to 690VAC 3NO 7.5 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM25 Power Contactors Up to 690VAC 3NO 11 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM32 Power Contactors Up to 690VAC 3NO 15 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM38 Power Contactors Up to 690VAC 3NO 18.5 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils Frequently Asked Questions
Are contactors from the DILM series equipped with protective circuits?
+ ‑ Every DILM contactor controlled by direct current (DC) has a built-in protective circuit. In smaller DILM7-15 models, it is possible to use an additional diode circuit that prevents operation with reversed DC polarity (model DILM12-XPSD). For contactors controlled by alternating current (AC), the protective circuit is standard from 115A upwards, and for smaller models accessories such as RC, varistor or varistor with signalling are available.
What functions do the built-in auxiliary contacts perform?
+ ‑ The NO auxiliary contact is used for the coil self-holding circuit during switching on (e.g. with self-resetting push-buttons) or for signalling the position of the main contacts. The NC auxiliary contact is used to detect damage to the main poles, such as welding caused by a short circuit. It is usually connected to the monitoring inputs of safety relays.
How to correctly select a contactor for an application?
+ ‑ To select the appropriate contactor, the contactor’s utilisation category must be taken into account, e.g. AC-3 (starting of a squirrel-cage asynchronous motor), the rated current of the load, and its switching frequency. In the case of a high number of switching operations per hour, it is recommended to use a contactor with higher power.
What should be considered when connecting conductors to the contactor?
+ ‑ Contactors with Push-in terminals can be connected with a ferrule-less wire, using a flat screwdriver to release the spring. In the case of contactors with screw terminals, the double cage terminal allows easy, convenient and safe connection of cables with different cross-sections.
Technical Data – AC Contactor
| Width | 45 mm |
| Height | 68 mm |
| Depth | 75 mm |
| Rated operational power for AC-3, 400 V | 4 kW |
| Number of main NO contacts | 3 |
| Number of Main NC Contacts | 0 |
| Number of NO auxiliary contacts | 0 |
| Number of NC auxiliary contacts | 1 |
| Rated Operating Current Ie for AC-3, 400 V | 9 A |
| Rated Operational Current Ie for AC-1, 400 V | 22 A |
| Rated control voltage Us for AC 50 Hz | 230 V |
| Rated control voltage Us for AC 60 Hz | 240 V |
| Main contact connection type | Screw Connection |
| Operating voltage for AC 50 Hz | 24 V |
| Operating Voltage for AC 60 Hz | 24 V |
| Control Voltage Type | AC |
| Rated Operational Current for AC-4, 400 V | 6 A |
| Rated Operational Power for AC-4, 400 V | 2.5 kW |
| NEMA Rated Operational Power | 3.7 kW |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,25 kg |
|---|---|
| Dimensions | 7,5 × 4,5 × 6,8 cm |
| Brand | Eaton |











Reviews
There are no reviews yet.