ETI ED2 160/3 Power Switch Disconnector 160A 3-Pole 690V AC Etibreak

174,20 € (141,63 € netto)

Lowest price in the last 30 days: 174,20 €

Reliable and proven ED2 compact isolating switches Compact isolating switches are used for switching circuits. A wide range of additional accessories is also available – shunt trip releases, undervoltage releases, remote control, motor drives, auxiliary contacts, alarm contacts, mechanical interlocks, extension terminals, cage terminals. Devices available in the range from 125 A to 1600 A in 3-pole and 4-pole versions. Technical parameters Catalogue Number: Individual identification number assigned by the manufacturer. 004671272 Product Code: Product type specified…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 004671272 Category: EAN: 3838895411055 Brand:

Description

Reliable and proven ED2 compact isolating switches Compact isolating switches are used for switching circuits. A wide range of additional accessories is also available – shunt trip releases, undervoltage releases, remote control, motor drives, auxiliary contacts, alarm contacts, mechanical interlocks, extension terminals, cage terminals. Devices available in the range from 125 A to 1600 A in 3-pole and 4-pole versions. Technical parameters

  • Catalogue Number:
  • Individual identification number assigned by the manufacturer. 004671272

  • Product Code:
  • Product type specified by the manufacturer. ED2 160/3

  • Class Name:
  • Compact isolating switches are used for switching circuits. isolating switch

  • Number of Poles:
  • Version of the compact circuit breaker: three-pole and four-pole. 3

  • Rated Current [A]:
  • Value of current, established by the manufacturer, that the device can conduct during continuous operation at a specified reference ambient air temperature. 160

  • Rated Voltage AC [V]:
  • The AC rated voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for its correct and safe operation. This value is provided by the device manufacturer and is taken into account in the design and use process. 690

  • Rated Voltage DC [V]:
  • DC rated voltage is the electrical voltage value specified for a given device, which is recommended or maximum permissible for correct and safe operation. This value is provided by the device manufacturer and is taken into account in the process of its design and use. 250

  • Rated Frequency [Hz]:
  • The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60

  • Rated insulation voltage [V]:
  • 800

  • Voltage Uimp [kV]:
  • Peak value of an impulse voltage surge of specified shape and polarity, which an electrical device can withstand without damage under specified test conditions, to which insulation clearance values relate. 8

  • Icm [kA]:
  • Rated making capacity Icm. 6

  • Icw [kA]:
  • Rated short-time withstand current Icw at 0.3s. 3

  • Mounting Method:
  • for panel mounting/
    TH rail adapter (004671186)

  • Ambient Temperature [˚C]:
  • Specified ambient air temperature of the complete switching device under defined conditions. For switching devices installed inside an enclosure, this is the air temperature outside the enclosure. -25 to + 50

  • Operating position:
  • Specification of the position in which the device can operate, e.g. horizontally, vertically, top-mounted, side-mounted. any

  • Standards:
  • Standards according to which the switching device was designed, tested and certified. EN 60947-3

  • Function:
  • Compact isolating switch, MCCB isolating switch

    Product photo*

    3D * the product photo may show a different, similar product from the series.

    Product advantages

    • Internal accessories of the ED2 series mostly fit all isolating switches and circuit breakers. Easy installation after removing the cover, without the need for special tools. Different shapes and colours allow easy identification of accessories. Accessories are described below the advantages section.
    • Marked lever positions ON, OFF, TRIP
    • To mechanically interlock 2 circuit breakers, the following types of interlocks can be used:
      -sliding interlock type: MS intended for devices up to 1600A.
      -rod (rigid) interlock type: MLR, MLL intended for devices up to 1000A.
      -cable interlock type: MW allows interlocking of devices of various sizes, up to 1000A maximum.
    • Direct manual drives, mounted on the isolating switch, or indirect drives, mounted on the cabinet door, are available for operating the isolating switch.
    • The isolating switches can be remotely controlled using motor drives.
    • SP2 cage terminals allow connection of solid or stranded wires (with ferrule) up to 400 A. Straight and extended ZB2 busbar connections allow connection of larger or double cables. Connections are available in sets for 3-pole and 4-pole isolating switches.
    • Power supply can be connected to the ED2 isolating switches from either side, without changing the technical parameters.
    • Protection against direct contact is achieved through double insulation of the enclosure, protection rating IP30 for the lever, IP20 for terminal covers, and additional interpole barriers.
    • Plug-in versions of isolating switches are available, allowing quick replacement for inspection purposes.

    Dimensional drawing

    Any mounting position of the ED2 isolating switch is permitted.
    Electrical connection of ED2 for 250V DC.

    Accessories

    ETIsON Curves

    Programme functionalities:

    • generating and plotting t/I characteristics of protective devices
    • adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
    • analysing selectivity between protective devices
    • simulating load or short-circuit response of protective devices
    • defining operating points and limit conditions from real applications
    • preparing reports for design documentation
    • Check how simple it is!

    Technical Data – Disconnector

    Rated Continuous Current Iu160 A
    Number of poles3
    Rated Operating Voltage230 V
    Rated conditional short-circuit current Iq65 kA
    Front side IP protection ratingIP20
    Main contact connection typeScrew Connection
    Actuating element typeLever
    As a compact switch disconnectorYes
    For installation in distribution boardsNo
    Device DesignPermanently Mounted Device

    Safety instructions: hilark.eu/gpsr/en.

    Additional information

    Weight1,576 kg
    Dimensions17,1 × 11,5 × 10,7 cm
    Brand

    ETI

    Rated Current

    125 A

    Reviews

    There are no reviews yet.

    Be the first to review “ETI ED2 160/3 Power Switch Disconnector 160A 3-Pole 690V AC Etibreak”