P312 DX3 B 16A/10MA/AC RCBO B 16A 1P+N 2M 10MA AC 6KA
77,85 € (63,29 € netto)
Residual current circuit breakers P 310 from the DX³ series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal AC residual currents – Type A – detects sinusoidal AC residual currents and pulsating DC residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Double pole 230V~ Type AC – Characteristic B – Rated residual current: 10 mA – Rated current: 16 A – Width in 17.5 mm modules: 2 – Mounting on TH35 rail – Can be connected using comb or pin busbars or…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Residual current circuit breakers P 310 from the DX³ series – Rated short-circuit breaking capacity 6000 A according to IEC 61009-1 – 230 V~ 6 kA according to IEC 60947-2 – 230 V~ – Type AC – detects sinusoidal AC residual currents – Type A – detects sinusoidal AC residual currents and pulsating DC residual currents – Compatible with the HX³ Optimised Power Distribution System up to 125 A Double pole 230V~ Type AC – Characteristic B – Rated residual current: 10 mA – Rated current: 16 A – Width in 17.5 mm modules: 2 – Mounting on TH35 rail – Can be connected using comb or pin busbars – Can be fitted with auxiliary contacts, trip units and actuators from the DX³ series – Grey operating lever
Technical data – Residual current circuit breaker with overcurrent protection
| Voltage Type | AC |
| Mounting Depth | 44 mm |
| Rated Current | 16 A |
| Rated Voltage | 230 V |
| Tripping Characteristic | B |
| Rated residual current | 0.01 A |
| Sensitivity | AC |
| Surge current resistance | 0.25 kA |
| Energy Limiting Class | 3 |
| Pollution degree (N) | 2 |
| Width in Number of Modules | 2 |
| Frequency | 50 Hz |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 1 |
| Rated short-circuit breaking capacity in accordance with IEC 60947-2 | 6 kA |
| Cross-section of connectable single-wire conductor | 0.75 mm2 |
| Cross-section of connectable multi-wire conductor | 0.75 mm2 |
| Number of Poles (Total) | 2 |
| Rated short-circuit breaking capacity Icn according to EN 61009-1 | 6 kA |
| Rated short-circuit breaking capacity according to EN 61009 | 6 kA |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,246 kg |
|---|---|
| Dimensions | 10,5 × 8,5 × 4 cm |
| Brand | Legrand |
| Length | 2 m |
| Rated Current | 16 A |



Reviews
There are no reviews yet.