Eaton HNB-C10/1N/003-A RCBO C10 1P+N, 2 Modules, 30 mA Type A 6 kA

59,92 € (48,72 € netto)

Lowest price in the last 30 days: 59,92 €

Eaton Residual Current Circuit Breaker with Overcurrent Protection 2P 10A 0.03A type A xPole Home HNB-C10/1N/003-A 195137 Main product features Robust combination of residual current and overcurrent protection functions in a single enclosure, independent of supply voltage. Double terminals (cage clamp/rail) on top and bottom Contact position indicator, red/green colour Testing required every 6 months, not every month Tripping independent of mains voltage Type A: sensitivity to pulsating residual current with DC component 2 protections in 1 device Protection against electric shock and enhanced fire protection…

Ships within 3–5 business days · delivery in approx. 5–7 business days

SKU: 195137 Category: EAN: 9010238061002 Brand:

Description

Eaton Residual Current Circuit Breaker with Overcurrent Protection 2P 10A 0.03A Type A xPole Home HNB-C10/1N/003-A 195137Key product featuresRobust and mains-voltage-independent combination of residual current and overcurrent protection functions in a single enclosure.Double terminals (cage/rail) on top and bottomContact position indicator, red/green colourTesting required every 6 months, not every monthVoltage-independent triggeringType A: sensitive to pulsating residual currents with DC component2 protections in 1 device
Protection against electric shock and enhanced fire protectionThe residual current circuit breaker integrated with the EATON overcurrent module protects the electrical installation against the effects of short circuits and overloads, enabling selective disconnection of only the faulty circuit.Protects against:FIRE | ELECTRIC SHOCK | DAMAGE TO ELECTRICAL EQUIPMENTWhy choose the Eaton surge arrester?Full safetyThe device effectively protects against the effects of electric shocks and surges caused by direct and indirect lightning strikes.Replaceable varistor cartridges (with fault indication)Integrated surge protection provides protection against mains disturbances, and damage to the varistor cartridge is immediately visible thanks to the built-in indicator.Quick device status verificationThe optical indicator shows the device status — a red signal indicates the need for replacement, while green confirms correct operation.easy to install, convenient to use
Device status information at your fingertipsCage and rail terminalGrey lever mechanically linked to the ON/OFF indicatorCan be sealed in the ON and OFF positionRed/green contact position indicatorSimple mounting on a DIN railTest button “T” (should be pressed every 6 months)Technical specification:

  • Tripping characteristic: C
  • Sensitivity: A
  • Installation depth [mm]: 69.5
  • Number of poles: 2
  • Overvoltage category: 3
  • Width expressed as number of modules: 2
  • Rated short-circuit breaking capacity in accordance with IEC 60947-2 [kA]: 0
  • Protection Rating (IP): IP20
  • Rated Residual Current [A]: 0.03
  • Rated Current [A]: 10
  • Energy limitation class: 3
  • Pollution degree: 2
  • Rated short-circuit breaking capacity in accordance with EN 60898 [kA]: 6

Each day we take care of the safety of electrical circuits worldwideCombined Circuit Breakers
in electrical installationsEATON residual current circuit breakers with overcurrent protection, also known as combined circuit breakers, combine two protective functions — overcurrent and residual current protection — in a single device. They protect the installation against overload and short circuit, while also protecting users against electric shock and increasing fire protection. In the event of a fault, they disconnect only the damaged circuit, minimising the risk of damage.A key advantage of the xPole Home series is its compact design — a single device takes up less space in the distribution board than two separate circuit breakers, without losing any of the required functionality.A product series designed for modern projectsThe new Eaton xPole circuit breakers stand out with excellent ergonomics, ensuring optimal operating temperature and improved electrical and mechanical durability.Optimal portfolioEasier selectionModern designHighest reliability and safetyEasy installationHigh durabilityThe circuit breaker is mounted on a DIN TH 35 mounting railThe device operates independently of the mounting position (vertical/horizontal)

  • Double cage/busbar terminals
  • Connecting busbar mounting on both sides top/bottom
  • After fitting the connecting busbar, a free cage terminal
  • Possibility of later fitting auxiliary contacts and trips

The next stage in the development of protective devicesThe Eaton xPole Home series represents a modern approach to electrical protection, combining advanced technologies with digital capabilities to provide an even higher level of safety and reliability.HN
Circuit Breakers

  • Protection against short circuits and overload
  • Basic fire protection

HNC residual current
circuit breakers

  • Earth fault protection
  • Basic fire protection
  • Protection against electric shock

HNB combined
circuit breakers

  • Earth fault protection
  • Protection against short circuits and overload
  • Enhanced fire protection

AFDD+ arc fault
detection device

  • Arc fault protection
  • Earth fault protection
  • Protection against short circuits and overload

Frequently Asked Questions Residual Current Circuit Breaker with Overcurrent ProtectionResidual current circuit breakers with overcurrent protection, also known as combined circuit breakers, combine the functions of an RCD and an MCB. In the EATON range, such devices can be found in the HNB and PKNM series.What is a residual current device?A residual current device (RCD) is a protective element in an electrical installation whose task is to protect users against electric shock.When should a residual current device be used?Its use is required in consumer installations, particularly where the PEN conductor has been split into separate PE and N conductors.Which type of residual current device should be chosen?The choice depends on the type of equipment connected to the installation. For standard sockets and lighting, a Type AC model is sufficient, while in the presence of electronic and power-electronic devices, Type A or Type F devices are recommended.Is the installation of an RCD mandatory?Yes – in accordance with building law regulations, the use of residual current devices in electrical installations is mandatory.Why does a residual current device trip?The device responds to leakage current, i.e. a situation where part of the current flows outside the protected circuit – this may indicate electric shock or insulation damage.In what situations does an RCD not protect against electric shock?Protection against direct contact is effective only for devices with a sensitivity of up to 30mA and circuits not exceeding 32A. At higher residual current values, such protection is not ensured.How does a residual current device work?The device analyses the balance between the current flowing into and out of the circuit. In the event of a difference – indicating potential current leakage – it automatically disconnects.How should a residual current device be correctly connected?Installation should be carried out in accordance with the manufacturer’s instructions and performed by a qualified electrician.Is there a residual current device that protects against fire?Yes, in accordance with EN HD 60364-4-42, RCDs with a sensitivity of up to 300mA can provide fire protection. Example models include PF6-40/4/03 and PFIM-63/4/03-S/F.

Technical data – Residual current circuit breaker with overcurrent protection

Voltage TypeAC
Mounting Depth69.5 mm
Rated Current10 A
Rated Voltage230 V
Tripping CharacteristicC
Rated insulation voltage Ui500 V
Rated residual current0.03 A
SensitivityA
Surge current resistance0.25 kA
Energy Limiting Class3
Overvoltage Category3
Pollution degree (N)2
Width in Number of Modules2
Frequency50 Hz
Protection Rating (IP)IP20
Number of Protected Poles1
Rated short-circuit breaking capacity in accordance with IEC 60947-20 kA
Cross-section of connectable single-wire conductor1 mm2
Cross-section of connectable multi-wire conductor1 mm2
Ambient operating temperature-25 °C
Number of Poles (Total)2
Rated impulse withstand voltage Uimp4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-16 kA
Tripping characteristic typeInstantaneous
Rated short-circuit breaking capacity according to EN 610096 kA

Lead time: 3-5 days.

Safety instructions: hilark.eu/gpsr/en.

Additional information

Weight0,21 kg
Dimensions7,2 × 8,5 × 3,5 cm
Brand

Eaton

Length

2 m

Rated Current

10 A

Reviews

There are no reviews yet.

Be the first to review “Eaton HNB-C10/1N/003-A RCBO C10 1P+N, 2 Modules, 30 mA Type A 6 kA”