Siemens 3RV Auxiliary Contact 1NO+1NC, Screw Terminals
8,68 € (7,06 € netto)
SIRIUS 3RV Circuit Breakers SIRIUS 3RV Circuit Breakers Safety You Can Afford Circuit breakers for your applications Motor circuit breakers and more SIRIUS 3RV is a series of circuit breakers most commonly used to protect motors. But that’s not all. Versions are also available with an overload relay function, for protecting star-delta starter combinations (without an overload element), for protecting transformers, for protecting installations (without load asymmetry monitoring), as well as versions compliant with UL 489. See which devices fall within the scope of SIRIUS 3RV circuit breakers Motor circuit breakers Equipped with a trip…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
SIRIUS 3RV Circuit Breakers
SIRIUS 3RV Circuit Breakers
Safety you can afford
Circuit breakers for your applications
Motor circuit breakers
and more
SIRIUS 3RV is a series of circuit breakers most commonly used to protect motors.
But that’s not all. Versions are also available with an overload relay function, for protecting star-delta starter combinations (without an overload element), for protecting transformers, for protecting installations (without load asymmetry monitoring), as well as versions compliant with UL 489.
See which devices fall within the scope of SIRIUS 3RV circuit breakers
Motor circuit breakers Equipped with a short-circuit trip and overload trip, an overload trip detecting load asymmetry (phase loss), suitable for motors with a rated current in the range of 0.11…100 A. Breaking capacity Icu up to 100 kA. Dedicated to starting class 10 and in a narrower range, class 20. Thanks to a short-circuit trip set at 13 times the rated current, suitable for motors in IE 3 design.
Circuit breakers with an overload relay function Similar to standard motor circuit breakers, dedicated to protecting electric motors with one difference – in the event of overload, no tripping occurs; instead, the built-in contact switches. This version is suitable for use wherever stopping the electric motor due to overload cannot be allowed.
Circuit breakers for protecting starter combinations Correct protection of a star-delta system requires the use of two devices. One performing the short-circuit protection function and the second (on the side of one of the conductors supplying the motor) performing the overload protection function. The 3RV23 series circuit breakers do not have a built-in overload trip, making them ideally suited for this task.
Circuit breakers for protecting transformers When switching on a transformer, the currents flowing through the protective device are significantly higher than during motor starting. This can lead to a situation in which switching on is not possible due to continuous tripping of the protective device. The 3RV24 series circuit breakers have been adapted for this task. Their short-circuit trip starts operating at 20 times the rated current.
Circuit breakers compliant with UL 489 Special versions compliant with UL 789 / CSA C22.2 No. 5 dedicated to protecting installations and devices other than motors (3RV27) and installations and transformers characterised by high inrush current (3RV28). At first glance, these versions are equipped with additional insulating elements designed to extend air and creepage clearances.
3RV29 mounting system The 3RV29 mounting system significantly reduces the time required for switchgear prefabrication. It is available in versions dedicated to devices with screw and/or spring terminals. Thanks to the use of dedicated connectors, errors that could occur with classic wiring are also significantly reduced.
Accessories Auxiliary and signalling contact blocks, wireless communication module. Isolating module with a visible isolating gap, undervoltage or overvoltage releases. Three-phase power busbars, adapters for 60 mm distribution rails, door operating mechanisms… thanks to the wide range of accessories, the 3RV series circuit breakers will meet every requirement.
Discover the benefits of using SIRIUS 3RV circuit breakers
Reliable operation
Motor circuit breakers are optimised for motor protection. Thanks to its design, the overload trip is able to protect the motor in the event of phase loss and load asymmetry. The circuit breaker setting can be easily adjusted to current installation conditions – i.e. ambient temperature. It is also worth noting that versions are available which can operate at an ambient temperature of -50°C.
Fast diagnostics
Short circuit or overload? This information is quite important from the point of view of ongoing maintenance. The circuit breaker’s trip mechanism is designed so that after it operates, the dial remains in the intermediate (TRIP) position, while detailed information on the cause of tripping is available via an additional signalling contact block.
Screw or spring terminals
Devices and accessories are available in versions with screw terminals or spring terminals. Spring terminals are available for devices up to 15 kW (32 A). Ring terminals are also available, but they are not popular.
Compatibility with other devices
SIRIUS components have been designed to work together as seamlessly as possible. The same applies in this case. Motor circuit breakers can be easily combined with 3RT series contactors, 3RW soft starters, and other devices from the SIRIUS range.
Reliable
operation
Fast
diagnostics
Type of
terminals
Compatibility with other
devices
See what questions other users have had
How to set a motor circuit breaker?
The overload trip setting value is set using the dial. The dial has a scaled correction for the installation method and ambient temperature.
Does the circuit breaker provide isolation from voltage?
In accordance with the requirements of EN 60204-1, the 3RV series circuit breakers are suitable for disconnection (isolation) from voltage. If a visible isolating gap is required, an additional isolating module can be used.
How to select a motor circuit breaker?
The circuit breaker should be safely selected at the middle of the overload trip range.
What is a starting class?
The starting class characterises the severity of starting. It defines the time interval within which the overload trip will operate when 7.2 times the setting current flows through a cold circuit breaker. For class 10, this is a time range of 4…10 s.
SIRIUS Industrial Switching Devices
Technical Data – Auxiliary Contact Block
| Mounting Method | Other |
| Lamp holder | None |
| Rated operational current Ie for AC-15, 230 V | 0.5 A |
| Type of Electrical Connection | Screw Connection |
| Number of fault signalling contacts | 0 |
| Number of NC Contacts | 1 |
| Number of NO Contacts | 1 |
| Number of Changeover Contacts | 0 |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,018 kg |
|---|---|
| Dimensions | 5 × 5,5 × 10,6 cm |
| Brand | Siemens |
| Rated Current | 32 A |