Eaton DILM25-10 Power Contactor 25 A 3NO+1NO 11 kW 24 V AC, Screw Terminals
71,78 € (58,36 € netto)
Eaton 0.9 277136 4015082771362 24_10_2023 Power contactor DILM25‑10 (24V50/60HZ) 25A 3P 24V AC 1NO 0NC 277136 Key product features The device is available in a screw connection version. It is equipped with one integrated auxiliary contact of NO or NC type, while Push-in technology models have two auxiliary contacts – NO and NC. Contactors powered by direct current (DC) have a built-in internal protective circuit. In variants with current from 17A upwards, an electronic coil is used, which is characterised by low energy consumption. They can be expanded with front auxiliary contacts…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton 0.9 277136 4015082771362 24_10_2023 Power contactor DILM25‑10 (24V50/60HZ)
25A 3P 24V AC 1NO 0NC 277136 Key product features The device is available in a screw connection version. It is equipped with one integrated auxiliary contact of NO or NC type, while Push-in technology models have two auxiliary contacts – NO and NC. Contactors powered by direct current (DC) have a built-in internal protective circuit. In variants with current from 17A upwards, an electronic coil is used, which is characterised by low energy consumption. They can be expanded with front auxiliary contacts and side-mounted auxiliary contactors. The use of a special mechanical-electrical adapter allows for quick and easy connection of the contactor with PKZ series motor-protective circuit-breakers. Designed for a wide current range Operating range from 7A to 2600A. Thanks to their compact design, electronic drives and high durability, DILM contactors are a solid and reliable solution for machines and systems in various industrial applications. DILM power contactors ‑ where are they used? Motor control DILM contactors are designed to handle motors, i.e. inductive loads, ensuring their effective switching on and off. Versatile use in industry They perform well in various industrial sectors – from machine building, through production lines, to maintenance. Ideal for installation in switchboards and control panels of machines and equipment. Control of resistive loads and lighting Thanks to their solid technical parameters, DILM contactors are also suitable for managing resistive loads (e.g. heaters) and various lighting systems. What distinguishes the DILM25 power contactor? Utilisation category AC‑1 and AC‑3 Suitable for voltage up to 1,000 V Electronic coil as standard from 17A for DC and from 115A for AC Low coil holding and pick-up power Compact size Auxiliary contacts: two NO, two NC Technical specification: Number of main NO contacts: 3 Number of auxiliary NC contacts: 0 Control voltage type: AC Main circuit connection type: Screw connection Product series: DILM Modular version: No Rated operational current Ie for AC‑1, 400 V [A]: 45 Rated operational power at AC‑3, 400 V [kW]: 11 Rated operational current Ie at AC‑3, 400 V [A]: 25 Mounting method for DILM contactors DILM contactors are equipped with double, independent terminal cages, allowing for secure and safe connection of two conductors with different cross-sections. This solution minimises the risk of conductor pull-out, protecting the installation against short circuit or electric shock. Contactors with high technical parameters They can be used for disconnecting local networks, operating drives controlled by frequency converters, conducting inductive and capacitive currents without switching them, and galvanic isolation of system parts when using inverters/frequency converters. Online motor starter configurator A practical tool enabling quick selection of contactors, motor-protective circuit-breakers and overload relays for direct, reversing and star-delta starting systems. Discover the advantages of DILM contactors Built with 3 main poles for three phases. One built-in auxiliary contact of NO (normally open) or NC (normally closed) type. Separate terminals for coil control (A1‑A2). Operating voltage Main current poles Rated operational power AC‑3 / 400 V [kW] Number of built-in auxiliary contacts Control coil Built-in suppressor circuit DILM7 power contactors Up to 690VAC 3NO 3 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM9 power contactors Up to 690VAC 3NO 4 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM12 power contactors Up to 690VAC 3NO 5.5 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM15 power contactors Up to 690VAC 3NO 7.5 1NO or 1NC Conventional AC and DC Varistor in DC-controlled coils DILM17 power contactors Up to 690VAC 3NO 7.5 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM25 power contactors Up to 690VAC 3NO 11 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM32 power contactors Up to 690VAC 3NO 15 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils DILM38 power contactors Up to 690VAC 3NO 18.5 1NO or 1NC Conventional AC, Electronic DC with low energy consumption and wider operating voltage range Varistor in DC-controlled coils Frequently Asked Questions
Are contactors from the DILM series equipped with protective circuits?
+ ‑ Every DILM contactor controlled by direct current (DC) has a built-in protective circuit. In smaller DILM7-15 models, it is possible to use an additional diode circuit that prevents operation with reversed DC polarity (model DILM12-XPSD). For contactors controlled by alternating current (AC), the protective circuit is standard from 115A upwards, and for smaller models accessories such as RC, varistor or varistor with signalling are available.
What functions do the built-in auxiliary contacts perform?
+ ‑ The NO auxiliary contact is used for the coil self-holding circuit during switching on (e.g. with self-resetting push-buttons) or for signalling the position of the main contacts. The NC auxiliary contact is used to detect damage to the main poles, such as welding caused by a short circuit. It is usually connected to the monitoring inputs of safety relays.
How to correctly select a contactor for an application?
+ ‑ To select the appropriate contactor, the contactor’s utilisation category must be taken into account, e.g. AC-3 (starting of a squirrel-cage asynchronous motor), the rated current of the load, and its switching frequency. In the case of a high number of switching operations per hour, it is recommended to use a contactor with higher power.
What should be considered when connecting conductors to the contactor?
+ ‑ Contactors with Push-in terminals can be connected with a ferrule-less wire, using a flat screwdriver to release the spring. In the case of contactors with screw terminals, the double cage terminal allows easy, convenient and safe connection of cables with different cross-sections.
Technical Data – AC Contactor
| Width | 45 mm |
| Height | 85 mm |
| Depth | 97 mm |
| Rated operational power for AC-3, 400 V | 11 kW |
| Number of main NO contacts | 3 |
| Number of Main NC Contacts | 0 |
| Number of NO auxiliary contacts | 1 |
| Number of NC auxiliary contacts | 0 |
| Rated Operating Current Ie for AC-3, 400 V | 25 A |
| Rated Operational Current Ie for AC-1, 400 V | 45 A |
| Rated control voltage Us for AC 50 Hz | 24 V |
| Rated control voltage Us for AC 60 Hz | 24 V |
| Main contact connection type | Screw Connection |
| Operating voltage for AC 50 Hz | 24 V |
| Operating Voltage for AC 60 Hz | 24 V |
| Control Voltage Type | AC |
| Rated Operational Current for AC-4, 400 V | 13 A |
| Rated Operational Power for AC-4, 400 V | 6 kW |
| NEMA Rated Operational Power | 11 kW |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,456 kg |
|---|---|
| Dimensions | 9,9 × 8,6 × 4,7 cm |
| Brand | Eaton |











Reviews