Eaton Miniature Circuit Breaker 1P C 63A 6kA AC xPole Home HN-C63/1 194837 Main product features Model 194837 features time-current characteristic C (so-called fast type) and a rated current of 63A. Breaking capacity is 6kA. Operation with 230VAC and 48VDC voltage Double terminals on both sides of the device — cage-clamp for cable and rail-type for busbars Meets insulation coordination requirements, contact gap of 3>4 mm to ensure safe insulation Mounting on DIN TH 35 rail Power supply from either side of the device A range of products ensuring protection and safety in modern installations Miniature circuit breakers…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Eaton Miniature Circuit Breaker 1P C 63A 6kA AC xPole Home HN-C63/1 194837Main product featuresModel 194837 features time-current characteristic C (so-called fast type) and a rated current of 63A. Breaking capacity is 6kA.Operation with 230VAC and 48VDC voltageDouble terminals on both sides of the device — cage-clamp for cable and rail-type for busbarsMeets insulation coordination requirements, contact gap of 3>4 mm to ensure safe insulationMounting on DIN TH 35 railPower supply from either side of the deviceA range of products ensuring protection and safety in modern installationsEATON miniature circuit breakers protect electrical installations against the effects of overloads and short circuits. They operate automatically – in the event of excessive current or a short circuit, they immediately break the circuit, preventing damage to the installation and increasing user safety.SOCKET CIRCUITS | LIGHTING CIRCUITS | TV/AUDIO AND HOUSEHOLD APPLIANCESWhy choose an Eaton miniature circuit breaker?Simplified designModern and minimalist design makes the device easy to operate and ensures it blends well with its surroundings.Resistance and durability against harsh environmentsThe breakers perform well both indoors and outdoors, thanks to high resistance to external factors.Compatibility with other devicesThe modular design allows easy equipping of the device with elements extending its functions – such as auxiliary contacts, trip units or locks.easy to install, convenient to use
Device status information at a glanceCage-clamp and rail-type terminalGrey lever mechanically linked with the ON/OFF indicatorCan be sealed in the ON and OFF positionRed/green contact position indicatorSimple mounting on DIN railTechnical specification:
- Model: HN-C63/1
- Protection Rating (IP): IP20
- Frequency [Hz]: 50
- Rated Voltage [V]: 230
- Installation depth [mm]: 70.5
- Rated short-circuit breaking capacity in accordance with EN 60898 [kA]: 6
- Pollution degree: 2
- Energy limitation class: 3
- Voltage type: AC
- Tripping characteristic: C
- Number of Poles: 1
- Rated Current [A]: 63
- Rated short-circuit breaking capacity in accordance with IEC 60947-2 [kA]: 0
- Width expressed in number of modules: 1
- Overvoltage category: 3
A miniature circuit breaker designed to protect electrical installations in low-voltage systemsAn overcurrent protection device (commonly known as a “fuse breaker”) is designed to protect the electrical installation against overload. Overload occurs when a circuit carries an excessively high current, which can happen when too many devices are connected to the same circuit. EATON miniature circuit breakers also provide protection against short circuits, which can occur when two conductors come into contact with each other, causing a high current flow and risk of damage to electrical devices. Type B circuit breakers are commonly used to protect sockets and lighting circuits, making them the most common protective device in electrical installations.Watch the video about miniature circuit breakers and discover the full range of overload protection devices from xPole HomeA range of products designed
for modern projectsThe new xPole Home product line, including HN miniature circuit breakers, HNB combined circuit breakers, and HNC residual current circuit breakers, has been designed to ensure maximum safety and efficiency in the design process. It is characterised by simple design, reliability, and full compliance with applicable standards. Devices from the xPole Home series are readily available and easy to install. HN miniature circuit breakers from this series work excellently in residential, commercial, and industrial installations, protecting both users and equipment.Advantages of the xPole Home seriesThe new Eaton xPole series circuit breakers stand out with excellent ergonomics, ensuring optimal operating temperature and improved electrical and mechanical durability.Optimal portfolioeasier selectionModern designHighest reliability and safetyeasy installationHigh durabilityThe next stage in the development of protective devicesEATON AFDD+ is not only an improved version of previous models, but also the next step in the development of protective devices, utilising the latest technologies and digital innovations.Protection against short circuits and overloadsEarth fault protectionArc fault protectionFire protectionEarth fault protectionHN
miniature circuit breakers+–basic-HNC
residual current circuit breakers-+-basic+HNB
combined circuit breaker++-enhanced+AFDD device++++extended+Frequently asked questionsStructure and operating principle of a miniature circuit breakerA miniature circuit breaker consists of two main components: a thermal bimetallic trip (overload) and an electromagnetic trip (short-circuit). It works to protect the electrical installation against overloads and short circuits, preventing fires or electric shock. In the event of prolonged overload, the thermal bimetallic trip heats up and causes the circuit to switch off. In the event of a short circuit, the electromagnetic trip reacts quickly and extinguishes the electric arc, preventing damage to devices.Which breaker: B or C?Miniature circuit breakers come with various tripping characteristics, such as Z, B, C, D, K, S. The B characteristic is used in socket circuits and traditional lighting (resistive loads), while the C characteristic is used for protecting devices with capacitive characteristics, such as LED lighting, induction hobs, gate actuators, or home automation.When does a miniature circuit breaker trip?A miniature circuit breaker trips when the current flowing through the circuit exceeds its rated value. For example, for a 10A breaker, this would be a current exceeding 11.3A. The second case is a short circuit, i.e. the flow of a very high current, which causes the breaker to trip immediately.How to connect a miniature circuit breakerEATON miniature circuit breakers are equipped with double terminals, allowing connection of cables (cage clamp terminals) or busbars (rail-type terminals). The connection should be made by a qualified electrician.Can a miniature circuit breaker fail?Yes, miniature circuit breakers are designed with a specific short-circuit withstand capacity. For example, the HN series is designed to break short circuits up to 6000A, in accordance with EN 60898-1. A higher short-circuit current may damage the device.Which breaker for an induction hob?Induction hobs typically require three-phase, three-pole circuit breakers. Depending on the power of the hob, an HN-B16/3 or HN-B20/3 breaker is used.Which breaker for lighting?To protect traditional incandescent or halogen lighting, an HN-B10/1 breaker (single-phase, 10A, B characteristic) is used. For LED lighting, especially in multi-family buildings in common areas, a breaker with a C characteristic is a better choice due to the high inrush currents of LED fittings.DC circuit breakerEATON miniature circuit breakers can operate with DC voltage up to 48V DC. For higher voltages, the PL7 DC or FAZ DC series are suitable, supporting voltages up to 250V DC or 500V DC in series connection.Which side should the circuit breaker be supplied from?EATON miniature circuit breakers are universal and can be supplied from either the bottom or the top. Regardless of the connection direction, the device will provide effective installation protection.Miniature circuit breakers vs residual current devicesMiniature circuit breakers protect against the effects of short circuits and overloads, and can also prevent fires and electric shocks. Residual current devices protect against electric shock as well as fires. In Polish electrical installations, both of these devices are mandatory and work in synergy, complementing each other.
Technical Data – Miniature Circuit Breaker
| Voltage Type | AC |
| Mounting Depth | 44 mm |
| Rated Current | 63 A |
| Rated Voltage | 230 V |
| Frequency Range | 50 Hz |
| Tripping Characteristic | C |
| Rated insulation voltage Ui | 440 V |
| Energy Limiting Class | 3 |
| Overvoltage Category | 3 |
| Pollution degree (N) | 3 |
| Width in Number of Modules | 1 |
| Power losses | 5.5 W |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 1 |
| Cross-section of connectable single-wire conductor | 1 mm2 |
| Cross-section of connectable multi-wire conductor | 1 mm2 |
| Ambient operating temperature | -25 °C |
| Number of Poles (Total) | 1 |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V | 6 kA |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V | 6 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V | 0 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V | 0 kA |
| Rated impulse withstand voltage Uimp | 4 kV |