ETI Etimat 10 Miniature Circuit Breaker C80 3-Pole 20 kA, 4.5 Modules
134,42 € (109,28 € netto)
Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters Catalogue Number: Individual identification number assigned by the manufacturer. 002135731 Product Code: Product type as specified by the manufacturer. ETIMAT 10 3p C80 Class Name: Miniature circuit breakers are used to protect electrical…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Reliable and Proven ETIMAT 10 Miniature Circuit Breakers ETIMAT 10 miniature circuit breakers are used to protect electrical installations in residential, public and industrial buildings. They provide reliable protection against short circuits and overloads in the protected electrical circuits. Technical Parameters
Individual identification number assigned by the manufacturer. 002135731
Product type as specified by the manufacturer. ETIMAT 10 3p C80
Miniature circuit breakers are used to protect electrical installations in residential, public, and industrial buildings. Miniature Circuit Breaker
The value of current, established by the manufacturer, that the device can carry during continuous operation at a specified reference ambient air temperature. 80
Miniature circuit breakers should have a tripping characteristic that ensures adequate circuit protection without premature or delayed tripping.
Standardised instantaneous tripping ranges:
– Type B (Above 3 In up to and including 5 In)
– Type C (Above 5 In up to and including 10 In)
– Type D (Above 10 In up to and including 20 In) C
Design version of the modular switching device: single-, double-, triple-, and four-pole. 3
Width of the device expressed as the number of standard 18 millimetre modules. 4.5
Overcurrent that occurs in the event of a short circuit resulting from damage or improper connection in the electrical circuit. 10
The rated AC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 230/400
The rated DC voltage is the value of electrical voltage specified for a given device, which is recommended or maximum permissible for proper and safe operation. This value is provided by the device manufacturer and is taken into account during its design and use. 60
The frequency of the supply voltage for which the electrical device is intended to operate and to which other characteristic values of the device refer. 50/60
Peak value of an impulse voltage of specified shape and polarity that an electrical device is able to withstand without damage under specified test conditions, to which the clearance values refer. 4
Degree of protection against access to hazardous parts and against the ingress of solid foreign objects and/or water, specified in accordance with EN 60529. IP20
The temperature of the air surrounding the complete switching device under specified conditions. For switching devices installed inside an enclosure, this refers to the air temperature outside the enclosure. -25 to +55
The distance between the main contacts of the switching device in the open position, expressed in millimetres. >3
Size of the switch’s connection terminal allowing connection of a conductor with an appropriate cross-section, expressed in mm2. 2.5 – 50
Standards according to which the device was designed, tested and certified. IEC/EN 60898-1,
IEC 60947-2
Miniature circuit breaker, MCB (ang. miniature circuit breaker) MCB
Product photo
3D
Product advantages
- possibility of installing auxiliary contacts (PSM ETIMAT 80/125).
- possibility of installing an undervoltage/shunt release (DA ETIMAT 80/125 110-415V).
- possibility of supply from below or above.
- possibility of double connection of the insulated pin-type busbar – top and bottom.
- contact position indicator.
- ability to seal the lever in the “On” and “Off” positions
- Each circuit breaker marked with an EAN code.
- Modern TH35 rail mounting method and easy replacement.
Dimensional drawing
ETIsON Curves
Programme functionalities:
- generating and plotting t/I characteristics of protective devices
- adjusting and testing protection settings, examining the impact of changes in the shape of the protection curve
- analysing selectivity between protective devices
- simulating load or short-circuit response of protective devices
- defining operating points and limit conditions from real applications
- preparing reports for design documentation
Check how simple it is!
Technical Data – Miniature Circuit Breaker
| Frequency | 50 Hz |
| Voltage Type | AC |
| Mounting Depth | 75 mm |
| Rated Current | 80 A |
| Rated Voltage | 415 V |
| Frequency Range | 50 Hz |
| Tripping Characteristic | C |
| Rated insulation voltage Ui | 440 V |
| Energy Limiting Class | 3 |
| Overvoltage Category | 3 |
| Pollution degree (N) | 3 |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 3 |
| Rated Short-Circuit Breaking Capacity according to EN 60898 | 10 kA |
| Rated short-circuit breaking capacity in accordance with IEC 60947-2 | 20 kA |
| Ambient operating temperature | -25 °C |
| Number of Poles (Total) | 3 |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V | 20 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V | 20 kA |
| Rated impulse withstand voltage Uimp | 4 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,71 kg |
|---|---|
| Dimensions | 7,8 × 11 × 9,2 cm |
| Brand | ETI |
| Length | 5 m |











Reviews
There are no reviews yet.