Schneider Electric Miniature Circuit Breaker Acti9 iC60N-B16-2 B 16A 2-Pole, A9F03216
12,80 € (10,41 € netto)
Miniature circuit breaker from the iC60N series, catalogue number A9F03216, iC60N-B16-2, 2-pole (two-pole), 16A, characteristic B, short-circuit breaking capacity 6kA, provides protection against short circuits and overloads. enterAbility to directly connect two cables of different cross-sections. Visi-Trip visual trip indicator, white-red. Ability to remove a single device without having to remove the connecting busbar. Removal from the DIN rail without the use of tools. Its limitation class 3 (in accordance with EN/IEC60898-1) improves the cost of outgoing circuit…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
Miniature circuit breaker from the iC60N series, catalogue number A9F03216, iC60N-B16-2, 2-pole (two-pole), 16A, characteristic B, short-circuit breaking capacity 6kA, provides protection against short circuits and overloads. enterAbility to directly connect two cables of different cross-sections. Visi-Trip visual trip indicator, white-red. Ability to remove a single device without having to remove the connecting busbar. Removal from the DIN rail without the use of tools. Its limitation class 3 (in accordance with EN/IEC60898-1) improves the cost of outgoing circuit protection. The unique Visi-Trip indicator reduces intervention time by showing the faulty circuit.
Technical Data – Miniature Circuit Breaker
| Frequency | 50 Hz |
| Voltage Type | AC/DC |
| Mounting Depth | 44.5 mm |
| Rated Current | 16 A |
| Rated Voltage | 400 V |
| Frequency Range | 50 Hz |
| Tripping Characteristic | B |
| Rated insulation voltage Ui | 500 V |
| Energy Limiting Class | 3 |
| Overvoltage Category | 4 |
| Pollution degree (N) | 3 |
| Width in Number of Modules | 2 |
| Power losses | 2.4 W |
| Protection Rating (IP) | IP20 |
| Number of Protected Poles | 2 |
| Rated Short-Circuit Breaking Capacity according to EN 60898 | 6 kA |
| Rated short-circuit breaking capacity in accordance with IEC 60947-2 | 10 kA |
| Cross-section of connectable single-wire conductor | 1 mm2 |
| Cross-section of connectable multi-wire conductor | 1 mm2 |
| Ambient operating temperature | -35 °C |
| Number of Poles (Total) | 2 |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 400 V | 6 kA |
| Rated Short-Circuit Breaking Capacity Icn according to EN 60898 at 230 V | 6 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 230 V | 20 kA |
| Rated Short-Circuit Breaking Capacity Icu according to IEC 60947-2 at 400 V | 10 kA |
| Rated impulse withstand voltage Uimp | 6 kV |
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,228 kg |
|---|---|
| Dimensions | 8,5 × 7 × 3,5 cm |
| Brand | Schneider Electric |
| Rated Current | 16 A |












Reviews
There are no reviews yet.