ERKO KCR 16-50/20 Tubular Ring Terminal DIN, 50 mm²
51,66 € (42,00 € netto)
KCR PIN LUGS BY ERKO Professional Cu pin lugs Manufactured to DIN 46235. KCR are galvanically tinned copper pin lugs for stranded Cu cables. The series has been designed for durable, repeatable and safe connections in power, industrial and distribution installations. KCR versions cover a wide range of metric cross-sections as well as AWG/kcmil equivalents, and UL certification confirms the product’s suitability for demanding international projects. Galvanically tinned Cu 10–625 mm² DIN 46235 UL Listed AWG/kcmil DIN Manufactured to DIN 46235 A dimensional standard valued in…
Ships within 3–5 business days · delivery in approx. 5–7 business days
Description
KCR PIN LUGS BY ERKO Professional Cu pin lugs Manufactured to DIN 46235. KCR are galvanically tinned copper pin lugs for stranded Cu cables. The series has been designed for durable, repeatable and safe connections in power, industrial and distribution installations. KCR versions cover a wide range of metric cross-sections as well as AWG/kcmil equivalents, and UL certification confirms the product’s suitability for demanding international projects. Galvanically tinned Cu 10–625 mm² DIN 46235 UL Listed AWG/kcmil DIN Manufactured to DIN 46235 A dimensional standard valued in industrial and power engineering projects, making it easier to select the right lug for technical documentation. UL UL Listed Certification A solution prepared for applications requiring confirmed quality and compliance with the requirements of international markets. KCR Range 10–625 mm² One series for a wide spectrum of applications: from smaller connections to large cross-section joints in high-current installations. Key Product Features Durable connectionLugs for class 5 stranded Cu cables — for stable and safe electrical contact. High conductivityGalvanically tinned copper reduces the risk of corrosion and supports reliable installation performance. Repeatable installationDedicated tools and die index marks make it easier to select the correct crimping process. Wide applicationFor switchgear, busbars, electrical apparatus, power engineering and industrial automation. Special versionsUntinned version available on request. Some index numbers have parameters outside DIN. Certification and Standard KCR: DIN 46235 + UL Listed The KCR series combines manufacture to the DIN 46235 standard with UL Listed certification. This is a practical solution for companies that need repeatable dimensions, a wide range of cross-sections and documented product quality at the same time. KCR — pin lug for stranded Cu cables, dimensions per datasheet Construction and Technical Parameters The KCR lug consists of a tubular part for crimping onto the cable and a flat eyelet part with a hole for a bolt. Dimensions are standardised according to DIN 46235, which simplifies design, selection and compatibility checking. The technical table includes conductor cross-section, bolt size, lug dimensions, weight, quantity per package, die index mark and recommended tools. MaterialGalvanically tinned Cu Cross-section range10–625 mm² StandardDIN 46235 Bolt holesM5–M20 CertificationUL Listed Country of manufacturePoland (Jonkowo) KCR Technical Table
| Conductor Cross-Section [mm²] | For M screw | d₂ [mm] | Terminal Designation | s [mm] | d₁ [mm] | d₃ [mm] | a [mm] | l₁ [mm] | l₂ [mm] | l [mm] | Weight [g/pc] | Quantity [pcs] | Die Index | Crimping Tools | AWG/kcmil |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 10 | M5 | 5,3 | KCR 5-10 | 0,75 | 4,5 | 10 | 9 | 7,5 | 8,5 | 27 | 3,56 | 50 | 6 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, GU120, HR100-U, PR240, PR50-D, PP19 | 8 AWG |
| M6 | 6,4 | KCR 6-10 | 9 | 8,5 | 8,5 | 3,65 | |||||||||
| M8 | 8,4 | KCR 8-10* | 9 | 10 | 10,5 | 3,60 | |||||||||
| 16 | M6 | 6,4 | KCR 6-16 | 1,5 | 5,5 | 20 | 13 | 7,5 | 9 | 36 | 12,08 | 50 | 8 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, GU120, HR100-U, PR240, PR50-D, PP19 | 6 AWG |
| M8 | 8,4 | KCR 8-16 | 13 | 10 | 11 | 12,24 | |||||||||
| M10 | 10,5 | KCR 10-16 | 13 | 12,5 | 12,5 | 12,80 | |||||||||
| 25 | M6 | 6,4 | KCR 6-25 | 1,5 | 7 | 20 | 14 | 9 | 9 | 38 | 15,92 | 50 | 10 | PR150-D + as above | 4 AWG |
| M8 | 8,4 | KCR 8-25 | 14 | 10 | 11,5 | 15,80 | |||||||||
| M10 | 10,5 | KCR 10-25 | 14 | 12,5 | 12,5 | 16,94 | |||||||||
| M12 | 13 | KCR 12-25 | 14 | 13 | 14 | 16,00 | |||||||||
| 35 | M6 | 6,4 | KCR 6-35* | 2,15 | 8,2 | 20 | 17 | 9 | 9 | 42 | 30,00 | 20 | 12 | PR50-D, R50, + as below | 2 AWG |
| M8 | 8,4 | KCR 8-35** | 17 | 10 | 11 | 30,15 | |||||||||
| M10 | 10,5 | KCR 10-35** | 17 | 12 | 13 | 30,45 | |||||||||
| M12 | 13 | KCR 12-35** | 17 | 14,5 | 14,5 | 31,55 | |||||||||
| M14 | 15 | KCR 14-35* | 17 | 15,5 | 15,5 | 30,70 | |||||||||
| 50 | M8 | 8,4 | KCR 8-50 | 2,25 | 10 | 28 | 20 | 10 | 11 | 52 | 45,35 | 20 | 14 | PR50-D, R50, + as below | 1/0 AWG |
| M10 | 10,5 | KCR 10-50 | 20 | 12 | 13 | 44,95 | |||||||||
| M12 | 13 | KCR 12-50 | 20 | 14,5 | 14,5 | 46,80 | |||||||||
| M14 | 15 | KCR 14-50* | 20 | 15,5 | 15,5 | 45,60 | |||||||||
| M16 | 17 | KCR 16-50 | 20 | 16 | 17 | 44,55 | |||||||||
| 70 | M8 | 8,4 | KCR 8-70 | 2,5 | 11,5 | 28 | 24 | 11,5 | 11,5 | 55 | 62,80 | 20 | 16 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, GU120, HR100-U, PR240, PR120-D, PR150-D | 2/0 AWG |
| M10 | 10,5 | KCR 10-70 | 24 | 12 | 13 | 62,50 | |||||||||
| M12 | 13 | KCR 12-70 | 24 | 14,5 | 14,5 | 61,30 | |||||||||
| M14 | 15 | KCR 14-70* | 24 | 15,5 | 15,5 | 61,90 | |||||||||
| M16 | 17 | KCR 16-70 | 24 | 16 | 17 | 71,55 | |||||||||
| 95 | M8 | 8,4 | KCR 8-95* | 2,75 | 13,5 | 35 | 28 | 10 | 11 | 65 | 91,00 | 10 | 18 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, GU120, HR100-U, PR240, PR120-D, PR150-D | 3/0 AWG |
| M10 | 10,5 | KCR 10-95 | 28 | 13,5 | 13,5 | 93,20 | |||||||||
| M12 | 13 | KCR 12-95 | 28 | 14,5 | 14,5 | 95,10 | |||||||||
| M14 | 15 | KCR 14-95* | 28 | 15,5 | 15,5 | 93,60 | |||||||||
| M16 | 17 | KCR 16-95 | 28 | 16 | 17 | 92,60 | |||||||||
| 120 | M10 | 10,5 | KCR 10-120 | 2,75 | 15,5 | 35 | 32 | 13,5 | 13,5 | 70 | 110,90 | 10 | 20 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, GU120, HR100-U, PR240, PR120-D, PR150-D | 250 kcmils |
| M12 | 13 | KCR 12-120 | 32 | 14,5 | 14,5 | 114,00 | |||||||||
| M14 | 15 | KCR 14-120* | 32 | 15,5 | 15,5 | 111,90 | |||||||||
| M16 | 17 | KCR 16-120 | 32 | 16 | 17 | 113,60 | |||||||||
| M20 | 21 | KCR 20-120 | 32 | 19 | 20 | 120,00 | |||||||||
| 150 | M10 | 10,5 | KCR 10-150 | 3,25 | 17 | 35 | 34 | 13,5 | 13,5 | 78 | 160,70 | 10 | 22 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, PR240, PR150-D | 300 kcmils |
| M12 | 13 | KCR 12-150 | 34 | 14,5 | 14,5 | 160,00 | |||||||||
| M14 | 15 | KCR 14-150* | 34 | 15,5 | 15,5 | 160,00 | |||||||||
| M16 | 17 | KCR 16-150 | 34 | 16 | 17 | 159,00 | |||||||||
| M20 | 21 | KCR 20-150 | 34 | 19 | 20 | 162,20 | |||||||||
| 185 | M10 | 10,5 | KCR 10-185 | 3,25 | 19 | 40 | 37 | 12 | 17 | 82 | 185,00 | 10 | 25 | PR240, PRZ240 + as below | 350 kcmils |
| M12 | 13 | KCR 12-185 | 37 | 13 | 17 | 180,00 | |||||||||
| M14 | 15 | KCR 14-185* | 37 | 15,5 | 15,5 | 185,00 | |||||||||
| M16 | 17 | KCR 16-185 | 37 | 16 | 17 | 192,00 | |||||||||
| M20 | 21 | KCR 20-185 | 37 | 19 | 20 | 190,30 | |||||||||
| 240 | M12 | 13 | KCR 12-240 | 3,75 | 21,5 | 40 | 42 | 13 | 17 | 92 | 265,00 | 10 | 28 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300 | 500 kcmils |
| M14 | 15 | KCR 14-240* | 42 | 15,5 | 15,5 | 270,00 | |||||||||
| M16 | 17 | KCR 16-240 | 42 | 16 | 17 | 270,00 | |||||||||
| M20 | 21 | KCR 20-240 | 42 | 19 | 20 | 277,70 | |||||||||
| 300 | M14 | 15 | KCR 14-300* | 3,75 | 24,5 | 50 | 48 | 15,5 | 15,5 | 100 | 334,00 | 1 | 32 | EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300 | |
| M16 | 17 | KCR 16-300 | 48 | 16 | 17 | 330,00 | |||||||||
| M20 | 21 | KCR 20-300 | 48 | 19 | 20 | 332,00 | |||||||||
| 400 | M14 | 15 | KCR 14-400* | 5,5 | 27,5 | 70 | 55 | 24 | 24 | 115 | 681,50 | 1 | 38 | GU625 | |
| M16 | 17 | KCR 16-400 | 55 | 24 | 24 | 672,96 | |||||||||
| M20 | 21 | KCR 20-400 | 55 | 24 | 24 | 600,00 | |||||||||
| 500 | M16 | 17 | KCR 16-500* | 5,5 | 31 | 70 | 60 | 24 | 24 | 125 | 740,00 | 1 | 42 | GU625 | |
| M20 | 21 | KCR 20-500 | 60 | 24 | 24 | 830,00 | |||||||||
| 625 | M16 | 17 | KCR 16-625* | 4,75 | 34,5 | 80 | 63* | 24 | 24 | 135 | 840,00 | 1 | 44 | GU625 | |
| M20 | 21 | KCR 20-625 | 63* | 24 | 24 | 820,00 |
Note: * index or parameter outside the DIN standard. ** fin thickness outside the DIN standard. Crimping instructions are available in the tool’s instruction manual/datasheet. Production and QualityDetail inspection mattersKCR lugs are designed with stable parameters, repeatable assembly and safe operation in industrial installations in mind. Galvanic tinning increases the surface resistance to operating conditions. ApplicationFor professional installationsThe KCR series performs well in switchgear, control cabinets, busbar connections, power engineering, automation and industry — wherever a durable electrical contact matters. Compatible toolsCorrect crimping of the KCR lugProper tool and die selection depends on the conductor cross-section and the specific lug index. The technical table shows die markings and recommended tools for individual ranges.A stable connection starts with the right tool.Example tools from the table: EPZC300, EPZ300, GZ300, HRZ300, PRZ240, GO300, HR300, GU300, PR240, PR150-D, GU625. Check out our other lugs ERKO KCS — outside the DIN standardCu tube lugs, galvanically tinned, in straight and angled versions KCS45 and KCS90. KCL — double-hole DIN 46235Double-hole tube lug for Cu cables, with tube section dimensions according to DIN 46235. KCZ — tapered lugSpecialist lug with a narrower eye section for locations with limited installation space. Discover the full range
of ERKO lugsERKO offers a wide range of cable lugs for professional applications: tube, ring, fork, ferrule, insulated and specialist types. You can also select compatible crimping tools — from hand crimpers to hydraulic solutions.One manufacturer — many professional solutions
Technical data – Crimped cable lug for copper conductors
| Insulated | No |
| Surface Protection | Tinning |
| Nominal cross-section | 50 mm2 |
| Connection Angle | 180° (Horizontal) |
| Number of mounting holes | 1 |
| Material | Copper |
| Metric thread size of the connection | 16 |
Minimum order quantity: 20 PCS.
Safety instructions: hilark.eu/gpsr/en.
Additional information
| Weight | 0,03 kg |
|---|---|
| Dimensions | 2 × 4,5 × 2 cm |
| Brand | Erko |








Reviews
There are no reviews yet.